基于自互信息的纹理分析用于超声乳腺病变分类
本研究提出一种基于自互信息(AMI)的纹理提取方法,用于乳腺超声(BUS)图像中良恶性病变的分类,并在2050幅BUS图像(1347例良性、703例恶性)上与九种常用纹理提取方法比较;采用1000次bootstrap样本评估,AMI方法的AUC、敏感度、特异度和MCC分别为0.82、0.80、0.85和0.63,优于对照方法。
要点
- AMI方法在BUS图像分类中AUC 0.82、敏感度0.80、特异度0.85、MCC 0.63。
- AMI方法性能优于九种常用纹理提取方法(AUC、敏感度、特异度、MCC)。
- AMI方法适合用于乳腺病变分类系统。
核心结论
- 实验结果表明,所提出的AMI方法在AUC、敏感度、特异度和MCC上均优于对照方法,提示其适合用于乳腺病变分类系统。
研究设计与样本
- 研究提出基于自互信息(AMI)的纹理提取方法,使用秩变换处理不同超声扫描仪采集的BUS图像强度变化,在水平与垂直方向提取AMI纹理特征,并以支持向量机作为分类器将乳腺病变分为良性与恶性;数据集由2050幅BUS图像组成(1347例良性、703例恶性),并与文献中九种常用纹理提取方法比较,采用1000次bootstrap样本评估分类性能。
诊断标准与关键数值
- AMI方法分类良恶性乳腺病变的AUC为0.82、敏感度为0.80、特异度为0.85、MCC为0.63。
- AMI方法在AUC、敏感度、特异度和MCC上均优于九种常用纹理提取方法。
临床应用与阅片要点
- 作者认为AMI方法适合用于乳腺病变分类系统。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Described here is a novel texture extraction method based on auto-mutual information (AMI) for classifying breast lesions. The objective is to extract discriminating information found in the non-linear relationship of textures in breast ultrasound (BUS) images. The AMI method performs three basic tasks: (i) it transforms the input image using the ranklet transform to handle intensity variations of BUS images acquired with distinct ultrasound scanners; (ii) it extracts the AMI-based texture features in the horizontal and vertical directions from each ranklet image; and (iii) it classifies the breast lesions into benign and malignant classes, in which a support-vector machine is used as the underlying classifier. The image data set is composed of 2050 BUS images consisting of 1347 benign and 703 malignant tumors. Additionally, nine commonly used texture extraction methods proposed in the literature for BUS analysis are compared with the AMI method. The bootstrap method, which considers 1000 bootstrap samples, is used to evaluate classification performance. The experimental results indicate that the proposed approach outperforms its counterparts in terms of area under the receiver operating characteristic curve, sensitivity, specificity and Matthews correlation coefficient, with values of 0.82, 0.80, 0.85 and 0.63, respectively. These results suggest that the AMI method is suitable for breast lesion classification systems.
引用
- Gómez-Flores W, Rodríguez-Cristerna A, de Albuquerque Pereira WC, et al. Texture Analysis Based on Auto-Mutual Information for Classifying Breast Lesions with Ultrasound. Ultrasound Med Biol. 2019. PMID: 31097332. doi:10.1016/j.ultrasmedbio.2019.03.018