文献速递乳腺乳腺X线

乳腺X线摄影阅片量对放射科医师读片表现的影响:挪威乳腺筛查项目结果

Influence of Mammography Volume on Radiologists' Performance: Results from BreastScreen Norway.
PubMed 文献 · Radiology · 2019-05-28

该回顾性研究分析挪威乳腺筛查项目2006至2016年数字乳腺X线摄影数据,纳入121名放射科医师共2 373 433次阅片,采用多水平混合效应模型评估年阅片量与累积阅片量对敏感度、筛查检出乳腺癌率及假阳性率的影响。结果显示年阅片量4000至10000例、累积阅片量大于20000例可能是实现高读片表现的最优阅片量。

要点

  • 年阅片量4000至10000例、累积阅片量大于20000例可能是达到高读片表现的最优阅片量。
  • 年阅片量100至10000例间敏感度约87%至90%,筛查检出乳腺癌率约4.9至4.7/1000次阅片。
  • 年阅片量与累积阅片量越高,共识会议前后假阳性率均呈下降趋势(趋势P < .001)。

核心结论

  • 年阅片量4000至10000例、累积阅片量大于20000例可能是独立双读筛查项目中实现高读片表现的最优阅片量。

研究设计与样本

  • 回顾性研究,纳入2006至2016年挪威乳腺筛查项目的数字乳腺X线摄影检查,共121名放射科医师完成2 373 433次阅片,采用多水平混合效应模型分析。

诊断标准与关键数值

  • 年阅片量100至10000例时敏感度相对稳定在87%至90%,筛查检出乳腺癌率4.9至4.7/1000次阅片(0.49%和0.47%)。
  • 累积阅片量500至100000例时敏感度相对稳定在88%至89%,筛查检出乳腺癌率4.8至4.9/1000次阅片(0.48%和0.49%)。
  • 年阅片量增至18000例时敏感度81%、筛查检出乳腺癌率3.9/1000次阅片(0.39%),随年阅片量升高呈下降趋势(趋势P < .001)。
  • 共识会议前假阳性率:年阅片量100例时5.3%、4000例时4.0%;累积阅片量500例时6.7%、20000例时3.6%。
  • 共识会议后假阳性率:年阅片量100例时2.5%、4000例时2.3%;累积阅片量500例时2.7%、20000例时2.2%。

临床应用与阅片要点

  • 作者认为年阅片量4000至10000例、累积阅片量大于20000例可能是独立双读筛查项目中实现高读片表现的最优阅片量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Several European screening mammography programs that use independent double reading with consensus recommend an annual minimum reading volume of 5000 mammograms per radiologist. This recommendation is based only on expert opinion, and the influence of reading volume on performance in such programs is unknown. Purpose To examine the influence of annual and cumulative reading volume on radiologists' reading performance for digital mammography in a screening program that uses independent double reading with consensus. Materials and Methods This retrospective study included data from digital mammographic examinations in BreastScreen Norway obtained from 2006 to 2016. Multilevel mixed-effects models were used to determine how sensitivity, rate of screening-detected breast cancer (SDC), and false-positive rate (FPR) before and after consensus meeting related to annual and cumulative reading volume. Results The study included 2 373 433 readings performed by 121 radiologists. The median annual reading volume ranged from 153 to 19 500 mammograms, and the median cumulative reading volume was 30 566 mammograms. Sensitivity and SDC rate were relatively stable at 87% to 90% and 4.9 to 4.7 per 1000 readings (0.49% and 0.47%), respectively, between 100 and 10 000 annual readings and at 88% to 89% and 4.8 to 4.9 per 1000 readings (0.48% and 0.49%) between 500 and 100 000 cumulative readings. There was a decreasing trend with higher annual volumes (P for trend < .001 for both) to a sensitivity of 81% and SDC rate of 3.9 per 1000 readings (0.39%) at 18 000 readings. There was a decreasing trend in FPR before and after consensus with higher annual and cumulative volumes (P for trend < .001 for all). FPRs before consensus meeting were 5.3% at 100 annual readings and 4.0% at 4000 annual readings and were 6.7% at 500 cumulative readings and 3.6% at 20 000 cumulative readings. FPRs after consensus meeting were 2.5% at 100 annual readings and 2.3% at 4000 annual readings and were 2.7% at 500 cumulative readings and 2.2% at 20 000 cumulative readings. Conclusion Annual reading volumes between 4000 and 10 000 mammograms and cumulative reading volumes greater than 20 000 mammograms may be the most optimal volumes for achieving high reading performance in a screening program with independent double reading. © RSNA, 2019 See also the editorial by Rosenberg and Seidenwurm in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Hoff SR, Myklebust TÅ, Lee CI, et al. Influence of Mammography Volume on Radiologists' Performance: Results from BreastScreen Norway. Radiology. 2019. PMID: 31135295. doi:10.1148/radiol.2019182684

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。