对比增强乳腺X线摄影与传统数字乳腺X线摄影在乳腺癌筛查中的比较:一项初步研究
该阅片研究纳入64例对比增强乳腺X线摄影(CEM)病例(48例阴性、5例活检良性、11例活检恶性),10名乳腺影像医师先评低能图再评CEM。CEM使中位敏感度从0.86升至1、中位特异度从0.85升至0.88,平均AUC提高0.056(P=0.002),5名医师平均信心显著提升(P<0.0001)。
要点
- CEM较单纯低能图提高中位敏感度(0.86 vs 1)和中位特异度(0.85 vs 0.88)。
- CEM使平均AUC提高0.056(95%CI 0.015-0.097),差异有统计学意义(P=0.002)。
- CEM在5名医师中显著提升平均诊断信心(P<0.0001),背景实质强化不影响信心提升程度。
核心结论
- CEM较仅观察低能图改善了阅片者表现和诊断信心,提示CEM在乳腺癌筛查中可能具有作用,但需更大规模试验验证。
研究设计与样本
- 经机构审查委员会批准的阅片研究,纳入2014年12月1日至2016年6月7日采集的64例去标识CEM病例,包括48例阴性、5例活检证实良性、11例活检证实恶性,阴性病例随访至少2年无癌证据;10名经验不一的乳腺影像医师先评低能乳腺X线图,再评CEM检查,使用BI-RADS分类和5点Likert量表评估诊断信心。
诊断标准与关键数值
- 中位敏感度:低能图0.86(95%CI 0.74-0.95)vs CEM 1(95%CI 0.83-1.00);中位特异度:低能图0.85(95%CI 0.64-0.94)vs CEM 0.88(95%CI 0.80-0.92);个体受试者工作特征曲线显示CEM显著改善,平均曲线下面积增加0.056(95%CI 0.015-0.097),P=0.002。
临床应用与阅片要点
- CEM在筛查中可能提高诊断信心和敏感度,尤其随组织密度增加信心改善呈趋势;背景实质强化程度不影响阅片者信心提升程度,但几乎完全脂肪型类别未见信心改善。
局限性
- 原文为初步研究,样本量小(64例),需更大规模试验验证(原文指出larger trials are warranted)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To perform a pilot evaluation of contrast-enhanced mammography (CEM) for screening to determine whether it can improve accuracy and reader confidence in diagnosis.
METHODS AND MATERIALS: This institutional review board-approved reader study was comprised of 64 de-identified CEM cases acquired from December 1, 2014, to June 7, 2016, including 48 negative, 5 biopsy-proven benign, and 11 biopsy-proven malignancies. Negative cases were followed for at least 2 years without evidence of cancer. Ten breast imagers of varying experience first rated the low-energy (LE) mammogram and then the CEM examination using BI-RADS categories and a 5-point Likert scale for confidence in diagnosis.
RESULTS: There were 635 out a total possible 640 complete reader interpretations included in this analysis. The remaining five incomplete interpretations were excluded. Median sensitivity and specificity improved with the addition of CEM (sensitivity: 0.86 [95% confidence interval {CI}: 0.74-0.95] versus 1 [95% CI: 0.83-1.00], specificity: 0.85 [95% CI: 0.64-0.94] versus 0.88 [95% CI: 0.80-0.92]). Individual receiver operating characteristic curves showed significant improvement with CEM (mean area under the curve increase = 0.056 [95% CI: 0.015-0.097], P = .002). The addition of CEM significantly improved average confidence in 5 of 10 readers when compared with LE (P < .0001) and improved pooled confidence across all tissue density categories, except the almost entirely fatty category. There was a trend toward improved confidence with increasing tissue density with CEM. Degree of background parenchymal enhancement did not affect readers' level of improvement in confidence when interpreting CEM.
SUMMARY: CEM improved reader performance and confidence compared with viewing only LE, suggesting a role for CEM in breast cancer screening for which larger trials are warranted.
引用
- Kim G, Phillips J, Cole E, et al. Comparison of Contrast-Enhanced Mammography With Conventional Digital Mammography in Breast Cancer Screening: A Pilot Study. J Am Coll Radiol. 2019. PMID: 31092346. doi:10.1016/j.jacr.2019.04.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。