文献速递乳腺US

乳腺病灶的剪切波弹性成像:弹性异质性的定量分析可提高诊断效能

Shear Wave Elastography of Breast Lesions: Quantitative Analysis of Elastic Heterogeneity Improves Diagnostic Performance.
PubMed 文献 · Ultrasound Med Biol · 2019-05-23

该前瞻性研究纳入2016年8月至2017年8月的280例患者,评估弹性异质性(EH)定量分析能否提高剪切波弹性成像(SWE)对乳腺病灶的诊断效能。结果显示EH的AUC为0.963,敏感度为93.75%,显著高于SWVmax和SWVmean的84.37%(p < 0.001),而三者特异度无显著差异(p > 0.05)。定量分析EH可在不损失特异度的情况下提高SWE鉴别乳腺病灶的敏感度。

要点

  • EH的AUC为0.963,高于SWVmax的0.949和SWVmean的0.937。
  • EH敏感度为93.75%,显著高于SWVmax和SWVmean的84.37%(p < 0.001)。
  • EH、SWVmax与SWVmean三者特异度无显著差异(p > 0.05)。

核心结论

  • 定量分析弹性异质性可提高SWE鉴别乳腺病灶的敏感度,且不损失特异度。

研究设计与样本

  • 前瞻性研究,2016年8月至2017年8月纳入280例患者,采用超声BI-RADS及虚拟触诊组织成像定量(Virtual Touch tissue imaging quantification)技术行SWE检查。

诊断标准与关键数值

  • EH定义为病灶内三个最高刚度区域平均SWV与三个最低刚度区域平均SWV之差。
  • EH的AUC为0.963,SWVmax的AUC为0.949,SWVmean的AUC为0.937。
  • EH的敏感度为93.75%,SWVmax的敏感度为84.37%,SWVmean的敏感度为84.37%(p < 0.001)。
  • EH、SWVmax与SWVmean三者特异度无显著差异(p > 0.05)。
  • 对于BI-RADS 4A类病灶,EH预测了所有恶性病灶,而SWVmax和SWVmean分别漏诊2个癌症。

临床应用与阅片要点

  • 在SWE检查中测量病灶内最高和最低刚度区域并计算EH,可辅助提高乳腺病灶鉴别的敏感度。
  • 对BI-RADS 4A类病灶,EH有助于减少SWVmax或SWVmean可能出现的漏诊。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The aim of this study was to evaluate whether quantitative analysis of elastic heterogeneity (EH) could improve the diagnostic performance of shear wave elastography (SWE) in breast lesions. From August 2016 to August 2017, 280 patients were enrolled in this prospective study. All lesions were evaluated with the ultrasound Breast Imaging Reporting and Data System (BI-RADS) and SWE with Virtual Touch tissue imaging quantification. The shear wave velocity (SWV) of the three areas of highest stiffness and lowest stiffness within the lesions were measured to calculate the maximum SWV (SWVmax), mean SWV (SWVmean) and EH. The EH was determined as the difference between the averaged highest SWV and lowest SWV. The diagnostic performance-including the area under the receiver operating characteristic curve (AUC) and the sensitivity and specificity of BI-RADS, EH, SWVmax and SWVmean-were analyzed. The AUC of EH, SWVmax and SWVmean were 0.963, 0.949 and 0.937, respectively. The sensitivity of EH was 93.75%, which was significantly higher than that of SWVmax (84.37%) and SWVmean (84.37%) (p < 0.001); there was no significant difference in the specificity among EH, SWVmax and SWVmean (p > 0.05). For category 4A lesions, EH predicted all the malignant lesions, while two cancers were misdiagnosed by SWVmax and SWVmean, respectively. Quantitative analysis of EH can improve the sensitivity of SWE for the differential diagnosis of breast lesions without loss of specificity.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Huang Y, Li F, Han J, et al. Shear Wave Elastography of Breast Lesions: Quantitative Analysis of Elastic Heterogeneity Improves Diagnostic Performance. Ultrasound Med Biol. 2019. PMID: 31130413. doi:10.1016/j.ultrasmedbio.2019.04.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。