文献速递乳腺US

超声计算机辅助诊断实性乳腺病灶:假阴性与假阳性结果的相关因素

Computer-Aided Diagnosis of Solid Breast Lesions With Ultrasound: Factors Associated With False-negative and False-positive Results.
PubMed 文献 · J Ultrasound Med · 2019-05-11

这项前瞻性研究纳入2017年9月至2018年5月269例连续女性患者的338个实性乳腺病灶,所有病灶在活检或手术切除前接受超声及S-Detect检查,并将影像评估与病理结果对照。结果显示,较大的良性病灶、B型超声检出钙化及Adler 2、3级血流与S-Detect假阳性相关;较小的恶性病灶及B型超声未见钙化与假阴性相关。

要点

  • S-Detect假阳性与较大病灶、B型超声检出钙化及Adler 2、3级血流相关。
  • S-Detect假阴性常见于较小恶性病灶及B型超声未见钙化的恶性病灶。
  • 判读S-Detect结果时需结合病灶大小、钙化及血流分级。

核心结论

  • 较大的良性病灶、存在病灶钙化及高程度血流可能表现为S-Detect假阳性结果。
  • 较小的恶性病灶及无钙化可能表现为S-Detect假阴性结果。

研究设计与样本

  • 前瞻性研究,经中山大学孙逸仙纪念医院机构审查委员会批准,所有患者在活检或手术前签署书面知情同意。
  • 2017年9月至2018年5月连续纳入269例女性患者的338个实性乳腺病灶,所有病灶在活检或手术切除前接受超声及S-Detect检查。
  • 将放射科医师的最终超声评估及S-Detect评估与病理结果对照,比较S-Detect真、假结果组的患者及病灶因素。
  • 采用多因素logistic回归分析识别与S-Detect假结果相关的因素。

诊断标准与关键数值

  • 338个病灶中良性209个(61.8%),恶性129个(38.2%)。
  • S-Detect假阳性相关因素:较大病灶(OR 1.071,P=.006)、B型超声检出病灶钙化(OR 5.851,P=.001)、Adler 2及3级血流(OR 1.726,P=.009)。
  • 恶性实性乳腺病灶中S-Detect假阴性相关因素:较小病灶(OR 1.141,P=.015)、B型超声未见钙化(OR 7.434,P=.016)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate factors that may lead to false-positive or false-negative results in a computer-aided diagnostic system (S-Detect; Samsung Medison Co, Ltd, Seoul, Korea) for ultrasound (US) examinations of solid breast lesions.

METHODS: This prospective study was approved by the Institutional Review Board of Sun Yat-sen Memorial Hospital. All patients signed and provided written informed consent before biopsy or surgery. From September 2017 to May 2018, 269 consecutive women with 338 solid breast lesions were included. All lesions were examined with US and S-Detect before biopsy or surgical excision. The final US assessments made by radiologists and S-Detect were matched to the pathologic results. Patient and lesion factors in the "true" and "false" S-Detect groups were compared, and multivariate logistic regression analyses were used to identify the factors associated with false S-Detect results.

RESULTS: The mean age of the patients ± SD was 42.6 ± 12.9 years (range, 18-77 years). Of the 338 lesions, 209 (61.8%) were benign, and 129 (38.2%) were malignant. Larger lesions, the presence of lesion calcifications detected by B-mode US, and grades of 2 and 3 according to Adler et al (Ultrasound Med Biol 1990; 16:553-559) were significantly associated with false-positive S-Detect results (odds ratio [OR], 1.071; P = .006; OR, 5.851; P = .001; OR, 1.726; P = .009, respectively). Smaller lesions and the absence of calcifications detected by B-mode US in malignant solid breast lesions were significantly associated with false-negative S-Detect results (OR, 1.141; P = .015; OR, 7.434; P = .016).

CONCLUSIONS: Larger benign lesions, the presence of lesion calcifications, and high degrees of vascularity are likely to show false-positive S-Detect results. Smaller malignant lesions and the absence of calcifications are likely to show false-negative S-Detect results.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Wu JY, Zhao ZZ, Zhang WY, et al. Computer-Aided Diagnosis of Solid Breast Lesions With Ultrasound: Factors Associated With False-negative and False-positive Results. J Ultrasound Med. 2019. PMID: 31077414. doi:10.1002/jum.15020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。