文献速递妇产影像泌尿生殖MR

影像组学鉴别子宫肉瘤与非典型子宫肌瘤的初步应用:MRI特征与影像组学特征诊断效能的比较

Preliminary utilization of radiomics in differentiating uterine sarcoma from atypical leiomyoma: Comparison on diagnostic efficacy of MRI features and radiomic features.
PubMed 文献 · Eur J Radiol · 2019-04-05

回顾性纳入78例(29例子宫肉瘤、49例子宫肌瘤)术前行盆腔MRI的患者,评估临床及MRI特征并由放射科医生做出诊断,同时基于ADC图构建影像组学模型预测病理结果。结果显示,老年女性的边界不清和子宫内膜腔中断是子宫肉瘤的预测因素;影像组学分析可行,最优影像组学模型与经验丰富的放射科医生诊断效能相当。

要点

  • 老年女性、肿瘤边界不清及子宫内膜腔中断是子宫肉瘤的预测因素。
  • 基于MRI特征,放射科医生诊断的AUC为0.752,敏感度58.6%、特异度91.8%、准确率79.5%。
  • 最优影像组学模型AUC为0.830,敏感度76.0%、平均特异度73.2%、准确率73.9%,与放射科医生诊断效能相当。

核心结论

  • 老年女性的边界不清和子宫内膜腔中断是子宫肉瘤的预测因素;影像组学分析可行,最优影像组学模型与经验丰富的放射科医生诊断效能相当。

研究设计与样本

  • 回顾性研究纳入78例(29例子宫肉瘤、49例子宫肌瘤)术前行盆腔MRI的患者,每例评估一个病灶的临床及MRI特征;放射科医生基于MRI特征做出诊断;基于ADC图的自动纹理分析构建影像组学模型预测病理结果;采用受试者工作特征曲线下面积(AUC)、敏感度、特异度和准确率比较放射科医生与影像组学模型的诊断效能。

关键影像表现/征象

  • 单因素分析显示,患者年龄、绝经状态、瘤内出血、肿瘤边界及子宫内膜腔与病理结果相关(P < 0.05)。
  • 多因素模型中,患者年龄、肿瘤边界及子宫内膜腔仍显著(P < 0.05)。

诊断标准与关键数值

  • 基于MRI特征,放射科医生诊断的AUC为0.752,敏感度58.6%,特异度91.8%,准确率79.5%。
  • 最优影像组学模型AUC为0.830,敏感度76.0%,平均特异度73.2%,准确率73.9%。

临床应用与阅片要点

  • 老年女性出现边界不清和子宫内膜腔中断的子宫肿瘤时,应警惕子宫肉瘤可能。
  • 影像组学分析可作为辅助手段,其诊断效能与经验丰富的放射科医生相当。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To explore whether MRI and radiomic features can differentiate uterine sarcoma from atypical leiomyoma. And to compare diagnostic performance of radiomic model with radiologists.

METHODS: 78 patients (29 sarcomas, 49 leiomyomas) imaged with pelvic MRI prior to surgery were included in this retrospective study. Certain clinical and MRI features were evaluated for one lesion per patient. Radiological diagnosis was made based on MRI features. A radiomic model using automated texture analysis based on ADC maps was built to predict pathological results. The association between MRI features and pathological results was determined by multivariable logistic regression after controlling for other variables in univariate analyses with P < 0.05. The diagnostic efficacy of radiologists and radiomic model were compared by area under the receiver-operating characteristic curve (AUC), sensitivity, specificity and accuracy.

RESULTS: In univariate analyses, patient's age, menopausal state, intratumor hemorrhage, tumor margin and uterine endometrial cavity were associated with pathological results, P < 0.05. Patient's age, tumor margin and uterine endometrial cavity remained significant in a multivariable model, P < 0.05. Diagnosis efficacy of radiologists based on MRI reached an AUC of 0.752, sensitivity of 58.6%, specificity of 91.8%, and accuracy of 79.5%. The optimal radiomic model reached an AUC of 0.830, sensitivity of 76.0%, average specificity of 73.2%, and accuracy of 73.9%.

CONCLUSIONS: Ill-defined tumor margin and interrupted uterine endometrial cavity of older women were predictors of uterine sarcoma. Radiomic analysis was feasible. Optimal radiomic model showed comparable diagnostic efficacy with experienced radiologists.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Xie H, Hu J, Zhang X, et al. Preliminary utilization of radiomics in differentiating uterine sarcoma from atypical leiomyoma: Comparison on diagnostic efficacy of MRI features and radiomic features. Eur J Radiol. 2019. PMID: 31084757. doi:10.1016/j.ejrad.2019.04.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。