文献速递泌尿生殖技术与安全MR

前列腺癌侵袭性预测:3.0 T 扫描仪上体素内不相干运动成像与扩散峰度成像超越 ADC 的优越诊断性能与最终病理 Gleason 评分对照

Prostate cancer aggressive prediction: preponderant diagnostic performances of intravoxel incoherent motion (IVIM) imaging and diffusion kurtosis imaging (DKI) beyond ADC at 3.0 T scanner with gleason score at final pathology.
PubMed 文献 · Abdom Radiol (NY) · 2019-01-01

研究探讨 IVIM 与 DKI 在预测前列腺癌 Gleason 评分中的诊断性能,对扩散加权成像数据后处理获得 ADC、D、Dstar、F、Dapp、Kapp 参数,与最终病理 Gleason 评分对照。结果显示各参数鉴别 GS≤3+4 与 GS>3+4、GS≤7 与 GS>7 的 AUC 均<0.05 显著,但各参数间 AUC 无显著差异,IVIM 与 DKI 模型均有助于预测 Gleason 评分并间接预测侵袭性,诊断性能与 ADC 相当。

要点

  • IVIM 与 DKI 模型均有助于预测前列腺癌 Gleason 评分并间接预测其侵袭性。
  • 各参数鉴别不同 Gleason 评分组的 AUC 间无显著差异,诊断性能与 ADC 相当。
  • Kapp 鉴别 GS>7 的 AUC 为 0.828,在所列参数中数值最高。

核心结论

  • IVIM 和 DKI 模型均有助于预测前列腺癌的 Gleason 评分并间接预测其侵袭性,两者之间以及两者与 ADC 之间的诊断性能相当。

研究设计与样本

  • 研究对扩散加权成像数据采用单指数、IVIM 和 DK 模型后处理,定量 ADC、D、Dstar、F、Dapp 和 Kapp,以最终病理 Gleason 评分为参考,采用 Spearman 秩相关系数、Kruskal-Wallis 检验、Mann-Whitney U 检验和 ROC 曲线分析。

诊断标准与关键数值

  • ADC 鉴别 GS≤3+4 与 GS>3+4 前列腺癌的 AUC 为 0.744(95%CI 0.581-0.868)。
  • F 鉴别 GS≤3+4 与 GS>3+4 前列腺癌的 AUC 为 0.726(95%CI 0.563-0.855)。
  • D 鉴别 GS≤3+4 与 GS>3+4 前列腺癌的 AUC 为 0.732(95%CI 0.569-0.860)。
  • Dapp 鉴别 GS≤3+4 与 GS>3+4 前列腺癌的 AUC 为 0.752(95%CI 0.590-0.875)。
  • Kapp 鉴别 GS≤3+4 与 GS>3+4 前列腺癌的 AUC 为 0.766(95%CI 0.606-0.885)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To explore the preponderant diagnostic performances of IVIM and DKI in predicting the Gleason score (GS) of prostate cancer.

METHODS: Diffusion-weighted imaging data were postprocessed using monoexponential, lVIM and DK models to quantitate the apparent diffusion coefficient (ADC), molecular diffusion coefficient (D), perfusion-related diffusion coefficient (Dstar), perfusion fraction (F), apparent diffusion for Gaussian distribution (Dapp), and apparent kurtosis coefficient (Kapp). Spearman's rank correlation coefficient was used to explore the relationship between those parameters and the GS, Kruskal-Wallis test, and Mann-Whitney U test were performed to compare the above parameters between the different groups, and a receiver-operating characteristic (ROC) curve was used to analyze the differential diagnosis ability. The interpretation of the results is in view of histopathologic tumor tissue composition.

RESULTS: The area under the ROC curves (AUCs) of ADC, F, D, Dapp, and Kapp in differentiating GS ≤ 3 + 4 and GS > 3 + 4 PCa were 0.744 (95% CI 0.581-0.868), 0.726 (95% CI 0.563-0.855), 0.732 (95% CI 0.569-0.860), and 0.752 (95% CI 0.590-0.875), 0.766 (95% CI 0.606-0.885), respectively, and those in differentiating GS ≤ 7 and GS > 7 PCa were 0.755 (95% CI 0.594-0.877), 0.734 (95% CI 0.571-0.861), 0.724 (95% CI0.560-0.853), and 0.716 (95% CI 0.552-0.847), 0.828 (95% CI 0.676-0.929), respectively. All the P values were less than 0.05. There was no significant difference in the AUC for the detection of different GS groups by using those parameters.

CONCLUSION: Both the IVIM and DKI models are beneficial to predict GS of PCa and indirectly predict its aggressiveness, and they have a comparable diagnostic performance with each other as well as ADC.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Shan Y, Chen X, Liu K, et al. Prostate cancer aggressive prediction: preponderant diagnostic performances of intravoxel incoherent motion (IVIM) imaging and diffusion kurtosis imaging (DKI) beyond ADC at 3.0 T scanner with gleason score at final pathology. Abdom Radiol (NY). 2019. PMID: 31144091. doi:10.1007/s00261-019-02075-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。