文献速递泌尿生殖腹部US

超微血管成像技术是准确进行肾囊性肿块Bosniak分级的合理选择

Superb microvascular imaging is a rational choice for accurate Bosniak classification of renal cystic masses.
PubMed 文献 · Br J Radiol · 2019-05-20

本研究以增强超声(CEUS)和病理为参照,评估常规超声联合超微血管成像(SMI)诊断肾囊性肿块的敏感度、特异度和准确度。结果显示SMI在评估IIf、III和IV级囊性肿块的血流及Bosniak分级方面与CEUS一致,且SMI鉴别良恶性的曲线下面积最高。

要点

  • SMI在观察肾囊性病灶分隔和实性结构血流方面优于彩色多普勒血流成像(CDFI)。
  • SMI与CEUS在肾囊性肿块Bosniak分级IIf、III和IV级中具有一致性。
  • SMI鉴别良恶性肾囊性病灶的曲线下面积最高,为0.869。

核心结论

  • SMI较CDFI能更好地显示肾囊性病灶分隔和实性结构的血流,从而更准确地进行Bosniak分级;SMI与CEUS在Bosniak分级上具有一致性;SMI辅助的Bosniak分级可能是一种准确的无创超声检查方法,用于鉴别良恶性肾囊性病灶。

研究设计与样本

  • 本研究通过比较常规超声联合SMI与CEUS及病理结果,评估常规超声联合SMI诊断肾囊性肿块的敏感度、特异度和准确度。

关键影像表现/征象

  • SMI较CDFI能更好地显示肾囊性病灶分隔和实性结构的血流。
  • CDFI与SMI在评估IIf、III和IV级肾囊性肿块的血流及Bosniak分级方面差异有统计学意义(p=0.020)。

诊断标准与关键数值

  • SMI鉴别良恶性肾囊性肿块的曲线下面积最高,为0.869(95%CI 0.743-0.995),p<0.001。
  • CEUS诊断敏感度最高,为97.4%。
  • SMI与CEUS在肾囊性肿块Bosniak分级IIf、III和IV级中具有一致性。

临床应用与阅片要点

  • 对于Bosniak分级IIf和III级的肾囊性病灶,常规超声鉴别恶性的能力有限。
  • SMI可用于观察肾囊性病灶分隔和实性结构的血流,辅助进行更准确的Bosniak分级。
  • SMI与CEUS在Bosniak分级IIf、III和IV级中具有一致性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Bosniak classification system provides a fine imaging evaluation for the malignant cystic renal masses. Superb microvascular imaging (SMI) is a new ultrasonic technique which apply advanced clutter suppression to reflect microflow information. The aim of this study was to evaluate the performance of ultrasound Bosniak classification aided by SMI in diagnosis of cystic renal masses.

METHODS: By comparing with contrast-enhanced ultrasound (CEUS) and pathology, we evaluated the sensitivity, specificity and accuracy of conventional ultrasound and SMI combination in the diagnosis of renal cystic masses.

RESULTS: Color Doppler Flow image (CDFI) and SMI had significant difference in evaluation the blood flow and Bosniak classification for cystic renal mass of IIf, III and IV (p = 0.020). SMI was consistent with CEUS for cystic renal mass Bosniak classification of IIf, III and IV. Although, CEUS had highest sensitivity of 97.4%, SMI had the highest area under curve in differential diagnosis malignance from benign masses [area under curve = 0.869 (0.743 - 0.995), p < 0.001].

CONCLUSION: SMI can display better in observing blood flow in septa and solid structures of renal cystic lesions compared with CDFI, thus, it can perform more accurate Bosniak classification for renal cystic mass. SMI and CEUS are consistent in Bosniak classification. Bosniak classification aided by SMI maybe an accurate non-invasive ultrasonic examination in distinguishing benign and malignant renal cystic lesions.

ADVANCES IN KNOWLEDGE: Conventional ultrasound had limited ability to distinguish malignance in Bosniak classifications IIf and III. SMI can display better in observing blood flow in septa and solid structures of renal cystic lesions compared with CDFI.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Mu J, Mao Y, Li F, et al. Superb microvascular imaging is a rational choice for accurate Bosniak classification of renal cystic masses. Br J Radiol. 2019. PMID: 31067075. doi:10.1259/bjr.20181038

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。