肾脏肿块:超声造影评估,特别关注假包膜征
本研究纳入163例连续患者的163个肾脏肿块,评估常规超声与超声造影(CEUS)特征,计算定性CEUS的敏感度、特异度及Az值,并对其中72例进行定量CEUS分析。假包膜征在定性CEUS特征中Az最高(0.777;95%CI 0.701-0.853),敏感度67.4%、特异度88.0%;多因素分析显示假包膜征与彩色多普勒血流成像模式是恶性最强的两个独立预测因子。定量CEUS中恶性肿块峰值强度更高、达峰时间更短,定性与定量评估间时间与强度的组内相关系数分别为0.00和0.03。
要点
- 假包膜征在定性CEUS特征中Az最高(0.777;95%CI 0.701-0.853),敏感度67.4%、特异度88.0%。
- 多因素logistic回归显示假包膜征与彩色多普勒血流成像模式是恶性最强的两个独立预测因子。
- 定量CEUS中恶性肾脏肿块峰值强度高于良性、达峰时间短于良性。
核心结论
- 假包膜征在所有定性和定量CEUS特征中诊断效能最高,是鉴别良恶性肾脏肿块的有效征象。
研究设计与样本
- 连续纳入163例患者的163个肾脏肿块,评估常规超声与CEUS特征;对163例中72例进行定量CEUS分析,比较良恶性肿块的达峰时间与峰值强度;计算定性与定量评估间强度和时间参数的组内相关系数。
关键影像表现/征象
- 假包膜征在定性CEUS特征中Az最高(0.777;95%CI 0.701-0.853),敏感度67.4%、特异度88.0%。
- 多因素logistic回归分析显示假包膜征和彩色多普勒血流成像模式是恶性最强的两个独立预测因子。
- 定量CEUS分析中,恶性肾脏肿块峰值强度高于良性肿块,达峰时间短于良性肿块。
诊断标准与关键数值
- 定性CEUS假包膜征诊断恶性的敏感度67.4%、特异度88.0%、Az 0.777(95%CI 0.701-0.853)。
- 定性与定量评估间组内相关系数:时间参数0.00,强度参数0.03。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The aim of this study was to analyze the diagnostic performance of contrast-enhanced ultrasound (CEUS) in differentiating between benign and malignant renal masses, with a special emphasis on the value of the pseudocapsule sign. A total of 163 consecutive patients with 163 renal masses were involved. The conventional ultrasonography and CEUS features were assessed. Sensitivity, specificity and the area under the receiver operating characteristic curve (Az) were calculated for qualitative CEUS, and a multivariate analysis was performed to analyze the correlation between the sonographic features and malignancy. Time to peak (TTP) and peak intensity (PI) were compared between benign and malignant renal masses for quantitative CEUS analysis in 72 of 163 patients. Intraclass correlations were calculated for variability in intensity and time parameters between qualitative and quantitative evaluation. Among all qualitative CEUS features, the pseudocapsule sign showed the highest Az (0.777; 95% confidence interval: 0.701-0.853) and yielded the highest sensitivity (67.4%) and specificity (88.0%); multivariate logistic regression analysis showed that the pseudocapsule sign and color Doppler flow imaging patterns were the two strongest independent predictors for malignancy. For quantitative CEUS analysis, higher PI and shorter TTP were found in malignant renal masses than those in benign ones. The Intraclass correlation coefficient values among qualitative and the quantitative assessments were 0.00 for time and 0.03 for intensity. The pseudocapsule sign offered the most efficient performance among all the qualitative and quantitative CEUS features.
引用
- Dai WB, Yu B, Diao XH, et al. Renal Masses: Evaluation with Contrast-Enhanced Ultrasound, with a Special Focus on the Pseudocapsule Sign. Ultrasound Med Biol. 2019. PMID: 31122812. doi:10.1016/j.ultrasmedbio.2019.03.020