对比增强诊断超声诱导大鼠肠道毛细血管出血
本研究用1.6兆赫相控阵探头对麻醉大鼠腹部进行模拟对比增强诊断超声扫描,在输注模拟Definity的微泡悬液时间歇触发双帧成像并改变输出功率。小肠黏膜和肌层出血点计数随触发间隔从2秒延长至10秒而增加,并在峰值负压超过1.4兆帕阈值后随输出增加而增加,派尔集合淋巴结也可见出血点,许多受累肠段检出潜血。
要点
- 模拟对比增强诊断超声扫描后,大鼠小肠黏膜和肌层出现出血点。
- 出血点计数随触发间隔从2秒延长至10秒而增加,提示微泡破坏后缓慢再填充。
- 峰值负压超过1.4兆帕阈值后,出血点计数随输出功率增加而增加。
核心结论
- 模拟对比增强诊断超声扫描可在1.4兆帕峰值负压阈值以上诱导大鼠小肠黏膜、肌层和派尔集合淋巴结毛细血管出血,并检出潜血,结果与早期实验室脉冲超声结果一致。
研究设计与样本
- 动物实验:麻醉大鼠腹部经1.6兆赫相控阵探头扫描,输注模拟Definity超声造影剂的微泡悬液,间歇触发双帧成像并改变输出功率评估暴露反应。
关键影像表现/征象
- 小肠黏膜和肌层出血点计数随触发间隔从2秒延长至10秒而增加,提示微泡破坏后缓慢再填充。
- 出血点计数在峰值负压超过1.4兆帕阈值后随输出增加而增加。
- 派尔集合淋巴结也可见出血点,许多受累肠段检出潜血。
诊断标准与关键数值
- 峰值负压阈值1.4兆帕:超过该阈值后出血点计数随输出功率增加而增加。
- 触发间隔从2秒延长至10秒:出血点计数随间隔延长而增加。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Contrast-enhanced diagnostic ultrasound (CEDUS) can lead to microvascular injury and petechial hemorrhage by the cavitational mechanism of ultrasonic bioeffects. Capillary hemorrhage has been noted in the heart and kidney, which are common targets of CEDUS examination. CEDUS has also become useful for monitoring intestinal inflammation. In the 1990s, the risk of intestinal microvascular hemorrhage was investigated both for incidental exposure by lithotripter shockwaves and for contrast agent microbubbles acting as cavitation nuclei with laboratory pulsed ultrasound systems. This study was initiated to update the risk assessment for intestine exposed to diagnostic imaging simulating CEDUS. The abdomens of anesthetized rats were scanned by a 1.6 MHz phased array probe during infusion of microbubble suspensions simulating Definity ultrasound contrast agent. Dual image frames were triggered intermittently, and the output power was varied to assess the exposure response. Petechiae counts in small intestine mucosa and muscle layers increased with increasing trigger interval from 2 s to 10 s, indicative of a slow refill after microbubble destruction. The counts increased with increasing output above a threshold of 1.4 MPa peak rarefactional pressure amplitude. Petechiae were also seen in Peyer's patches, and occult blood was detected in many affected segments of intestine. These results are consistent with early laboratory pulsed-ultrasound results.
引用
- Lu X, Dou C, Fabiilli ML, et al. Capillary Hemorrhage Induced by Contrast-Enhanced Diagnostic Ultrasound in Rat Intestine. Ultrasound Med Biol. 2019. PMID: 31101449. doi:10.1016/j.ultrasmedbio.2019.04.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。