限制频谱成像在疑似前列腺癌首次活检男性中的应用价值
研究纳入198例首次活检的疑似前列腺癌男性,行多参数MRI含限制频谱成像(RSI)并接受MRI-超声融合活检,比较RSI与传统DWI对临床显著前列腺癌(Gleason≥3+4)的诊断性能。RSI与DWI总体诊断准确性分别为0.70和0.68(p=0.74),但RSI在移行带病变特异度更高。
要点
- RSI与DWI对临床显著前列腺癌的总体诊断准确性无显著差异(0.70 vs 0.68,p=0.74)。
- 移行带病变中RSI特异度69%高于ADC特异度17%,敏感度59%低于ADC的94%。
- 外周带临床显著癌中RSI z评分与ADC显著负相关(ρ=-0.4852,p<0.01),移行带无显著相关(ρ=-0.2412,p=0.17)。
核心结论
- 在首次前列腺活检的疑似前列腺癌男性中,RSI与DWI诊断性能相当,但RSI对移行带病变特异度更优。
研究设计与样本
- 前瞻性临床试验的同期队列,198例首次活检男性,行多参数MRI含RSI及MRI-超声融合活检,以Gleason评分≥3+4为临床显著前列腺癌参考标准。
关键影像表现/征象
- RSI z评分与ADC在临床显著癌外周带显著负相关(ρ=-0.4852,p<0.01),移行带无显著相关(ρ=-0.2412,p=0.17)。
诊断标准与关键数值
- ADC≤1000 μm2/s阈值下,临床显著前列腺癌敏感度86%、特异度38%。
- RSI z评分≥3阈值下,临床显著前列腺癌敏感度61%、特异度70%。
- 移行带(n=69)ADC≤1000 μm2/s敏感度94%、特异度17%;RSI z评分≥3敏感度59%、特异度69%。
- RSI与DWI总体诊断准确性分别为0.70和0.68(p=0.74)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this article is to evaluate restriction spectrum imaging (RSI) in men undergoing MRI-ultrasound fusion biopsy for suspected prostate cancer (PCa) and to compare the performance of RSI with that of conventional DWI. MATERIALS AND METHODS. One hundred ninety-eight biopsy-naïve men enrolled in a concurrent prospective clinical trial evaluating MRI-targeted prostate biopsy underwent multiparametric MRI with RSI. Clinical and imaging features were compared between men with and without clinically significant (CS) PCa (MRI-ultrasound fusion biopsy Gleason score ≥ 3 + 4). RSI z score and apparent diffusion coefficient (ADC) were correlated, and their diagnostic performances were compared. RESULTS. CS PCa was detected in 109 of 198 men (55%). Using predefined thresholds of ADC less than or equal to 1000 μm2/s and RSI z score greater than or equal to 3, sensitivity and specificity for CS PCa were 86% and 38%, respectively, for ADC and 61% and 70%, respectively, for RSI. In the transition zone (n = 69), the sensitivity and specificity were 94% and 17%, respectively, for ADC and 59% and 69%, respectively, for RSI. Among lesions with CS PCa, RSI z score and ADC were significantly inversely correlated in the peripheral zone (ρ = -0.4852; p < 0.01) but not the transition zone (ρ = -0.2412; p = 0.17). Overall diagnostic accuracies of RSI and DWI were 0.70 and 0.68, respectively (p = 0.74). CONCLUSION. RSI and DWI achieved equivalent diagnostic performance for PCa detection in a large population of men undergoing first-time prostate biopsy for suspected PCa, but RSI had superior specificity for transition zone lesions.
引用
- Felker ER, Raman SS, Shakeri S, et al. Utility of Restriction Spectrum Imaging Among Men Undergoing First-Time Biopsy for Suspected Prostate Cancer. AJR Am J Roentgenol. 2019. PMID: 31039011. doi:10.2214/AJR.18.20836
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。