文献速递腹部泌尿生殖CT

双能CT与减影CT对肾脏病灶检测与定性的诊断效能

Diagnostic performance of dual-energy CT and subtraction CT for renal lesion detection and characterization.
PubMed 文献 · Eur Radiol · 2019-05-27

回顾性纳入114例疑似肾肿块患者,比较三组图像对230个病灶的诊断效能。A组(碘密度图+水密度图)与C组(减影CT+真非增强期+65keV虚拟单能图)AUC分别为0.88和0.87,均高于B组(仅减影CT)的0.75;A组阅片速度更快(41.49秒 vs 71.45秒)。碘浓度与ΔHU鉴别强化与非强化病灶AUC均为0.97。

要点

  • 碘密度图图像质量评分高于减影CT(3.82 vs 3,p<0.05),可提升读片信心。
  • 碘密度图方案诊断效能与多序列减影CT方案相当,且阅片时间更短(41.49秒 vs 71.45秒)。
  • 碘浓度与ΔHU鉴别强化与非强化病灶的AUC均为0.97,碘浓度鉴别透明细胞肾细胞癌与其他强化病灶AUC为0.73。

核心结论

  • 碘密度图可提高肾脏病灶检测与定性的读片信心并优化放射科工作流程,且不受读片者经验影响。

研究设计与样本

  • 回顾性研究,纳入2015年1月至2018年2月间因疑似肾肿块行增强双能CT的114例患者(男69例、女45例,平均年龄67岁),共230个病灶(平均大小23.63 mm,范围5-116 mm),由3名放射科医生评估三组图像数据集。

关键影像表现/征象

  • 病灶构成包括60个强化病灶、158个非强化病灶和12个脂质为主型血管平滑肌脂肪瘤。
  • 碘密度图的图像质量评分显著高于减影CT(平均评分3.82 vs 3,p<0.05)。

诊断标准与关键数值

  • A组(碘密度图+水密度图)诊断肾脏病灶的AUC为0.88,C组(减影CT+真非增强期+65keV虚拟单能图)AUC为0.87,B组(仅减影CT)AUC为0.75。
  • 碘浓度与ΔHU鉴别强化与非强化病灶的AUC均为0.97。
  • 碘浓度鉴别透明细胞肾细胞癌与其他强化病灶的AUC为0.73,为中等准确度。

临床应用与阅片要点

  • 碘密度图方案读片速度快于多序列减影CT方案(41.49秒 vs 71.45秒每例,p<0.05),可能减少对定量测量的依赖。
  • 双能CT的高准确度可能通过避免额外检查而降低医疗成本。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the effect of dual-energy CT (DECT) material density datasets on diagnostic performance, readers' confidence, and interpretation time for renal lesion detection and characterization in comparison to subtraction CT (SCT).

MATERIAL AND METHODS: One hundred fourteen patients (69/45 = M/F, mean age = 67 years) who underwent contrast-enhanced DECT between January 2015 and February 2018 for suspected renal mass were included retrospectively. For each patient, three radiologists assessed three image datasets: group A, material density iodine (MDI) + material density water (MDW); group B, SCT only; and group C, SCT + true unenhanced phase + virtual monochromatic images at 65 keV. Readers evaluated image quality (4-point scale), the number of lesions, and likely diagnosis. Reading times were recorded. Quantitatively, iodine concentration (IC from MDI) and delta Hounsfield units (ΔHU) for all lesions were measured. Diagnostic accuracy was compared using the area under the receiver operating characteristic curve (AUC). Image quality and interpretation time were compared with Kruskal-Wallis and t tests.

RESULTS: Study cohort (230 lesions; mean size = 23.63 mm (5-116 mm)) consisted of 60 enhancing, 158 non-enhancing, and 12 lipid-dominant angiomyolipoma lesions. Significantly higher image quality was demonstrated for MDI compared to SCT (mean score = 3.82 vs. 3; p < 0.05). Comparable diagnostic accuracy was observed for group A (AUC = 0.88) and group C (AUC = 0.87) and was higher compared to that for group B (AUC = 0.75). Group A was read faster than group C (41.49 s vs. 71.45 s per exam; p < 0.05). Both IC and ΔHU values had high accuracy (AUC = 0.97) for differentiating enhancing vs. non-enhancing lesions; however, IC enabled differentiation of clear cell renal cell carcinoma from other enhancing lesions with moderate accuracy (AUC = 0.73).

CONCLUSION: MDI images increase readers' confidence for renal lesion detection and characterization while providing a more efficient radiologist workflow, irrespective of readers' experience.

KEY POINTS: • Material density iodine (MDI) images enable faster interpretation due to high image quality and potentially reduced need for quantitation. • MDI images increase diagnostic confidence of readers, irrespective of radiologists' experience. • High accuracy with dual-energy CT (DECT) can potentially reduce healthcare costs by eliminating the need for additional investigations.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Pourvaziri A, Parakh A, Mojtahed A, et al. Diagnostic performance of dual-energy CT and subtraction CT for renal lesion detection and characterization. Eur Radiol. 2019. PMID: 31134365. doi:10.1007/s00330-019-06224-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。