低剂量CT联合自适应统计迭代重建V技术评估腹部脏器损伤:与常规剂量CT联合滤波反投影的比较
本研究纳入197例腹部多期CT创伤患者,比较常规剂量门静脉期FBP与低剂量延迟期50% ASIR-V对肝、脾、胰、肾损伤的检出和AAST分级。低剂量方案平均剂量降低59.8%,两种方案检出率(p=0.289)和分级诊断性能(p>0.999)无显著差异,低剂量方案客观噪声更低(p<0.001),主观伪影相似(p=0.539)。
要点
- 低剂量延迟期50% ASIR-V方案平均剂量较常规剂量门静脉期FBP降低59.8%。
- 两种方案对腹部脏器损伤的检出率(p=0.289)和AAST分级诊断性能(p>0.999)无显著差异。
- 低剂量方案客观图像噪声显著低于常规剂量方案(p<0.001),主观伪影相似(p=0.539)。
核心结论
- 与常规剂量FBP方案相比,低剂量CT联合ASIR-V在不损害图像质量的前提下有助于评估多脏器腹部损伤。
研究设计与样本
- 研究纳入197例创伤患者,均行腹部多期CT,包括常规剂量门静脉期FBP和低剂量延迟期50% ASIR-V;以AAST分级为参考标准评估肝、脾、胰、肾损伤。
关键影像表现/征象
- 低剂量延迟期50% ASIR-V方案较常规剂量门静脉期FBP方案平均剂量降低59.8%。
- 低剂量方案客观图像噪声显著低于常规剂量方案(p<0.001)。
- 低剂量与常规剂量方案的主观成像伪影相似(p=0.539)。
诊断标准与关键数值
- 腹部脏器损伤(肝、脾、胰、肾)按美国创伤外科协会(AAST)分级标准分级。
- 两种方案对脏器损伤的检出率无显著差异(p=0.289)。
- 两种方案对AAST分级的诊断性能无显著差异(p>0.999)。
临床应用与阅片要点
- 低剂量延迟期50% ASIR-V可用于腹部脏器损伤的评估,检出率和AAST分级与常规剂量FBP无显著差异。
- 低剂量方案平均剂量较常规剂量降低59.8%,且客观噪声更低、主观伪影相似。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study was to evaluate and compare the diagnostic performance and image quality of low-dose CT performed with adaptive statistical iterative reconstruction (ASIR)-V with those of routine-dose CT with filtered back projection (FBP) in the evaluation of abdominal organ injury. MATERIALS AND METHODS. The study enrolled 197 patients with trauma who underwent multiphase abdominal CT, including routine-dose portal venous phase imaging with FBP and low-dose delayed phase imaging with 50% ASIR-V. The presence of abdominal organ injuries (liver, spleen, pancreas, kidney) was reviewed, and injuries were graded according to American Association for the Surgery of Trauma (AAST) scales. CT detection rates of organ injury and AAST grading with the two protocols were compared by McNemar test. Subjective analysis of image noise and artifacts and objective analysis of CT noise were performed by unpaired t test. RESULTS. Compared with the routine-dose protocol, the low-dose protocol enabled an mean dose reduction of 59.8%. The detection rates and diagnostic performance of AAST grading did not differ significantly between the two protocols (detection rate, p = 0.289; diagnostic performance, p > 0.999). Objective image noise was significantly less with the low-dose protocol than with the routine-dose protocol (p < 0.001). Subjective imaging artifacts were similar between the low-dose and routine-dose protocols (p = 0.539). CONCLUSION. Compared with routine-dose protocol with FBP, low-dose CT with ASIR-V was useful for assessing multiorgan abdominal injury without impairing image quality.
引用
- Lee NK, Kim S, Hong SB, et al. Low-Dose CT With the Adaptive Statistical Iterative Reconstruction V Technique in Abdominal Organ Injury: Comparison With Routine-Dose CT With Filtered Back Projection. AJR Am J Roentgenol. 2019. PMID: 31039013. doi:10.2214/AJR.18.20827
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。