文献速递腹部MR

3T磁共振胰胆管成像:三维压缩感知与二维单次激发采集的图像质量比较

Magnetic resonance cholangiopancreatography at 3 Tesla: Image quality comparison between 3D compressed sensing and 2D single-shot acquisitions.
PubMed 文献 · Eur J Radiol · 2019-04-15

回顾性评估53组3T磁共振胰胆管成像数据,比较呼吸触发压缩感知三维、屏气压缩感知三维与二维单次激发屏气采集的图像质量。压缩感知图像在整体质量、背景抑制、模糊及胰胆管结构辨识度上均优于二维单次激发;呼吸触发压缩感知三维除模糊外各项评分优于屏气压缩感知三维。屏气压缩感知三维可在单次屏气内获得诊断质量图像并显著缩短扫描时间。

要点

  • 压缩感知三维磁共振胰胆管成像的图像质量、背景抑制及胰胆管结构辨识度优于二维单次激发屏气采集。
  • 呼吸触发压缩感知三维除模糊外各项评分优于屏气压缩感知三维,但扫描时间更长(3分48秒 vs 17秒)。
  • 屏气压缩感知三维在单次屏气17秒内即可获得诊断质量图像。

核心结论

  • 压缩感知可实现容积图像数据采集,图像质量优于二维单次激发屏气采集;屏气压缩感知三维在显著提升采集速度的同时对伪影稳健,单次屏气采集即可获得诊断质量图像。

研究设计与样本

  • 回顾性评估53组数据集,在3T MRI上采集呼吸触发压缩感知三维(RT-CS10)、屏气压缩感知三维(BH-CS24)和二维单次激发屏气(2D-SSBH)磁共振胰胆管成像;由2名放射科医师采用4分法对整体图像质量、模糊/运动伪影及胰胆管树结构辨识度评分,并通过感兴趣区分析测量胆总管与邻近组织的对比度,用线剖面量化胆管边界信号强度增加以客观表征模糊和运动伪影。

关键影像表现/征象

  • 压缩感知采集的图像在整体图像质量、背景抑制、模糊及胰胆管树结构辨识度方面评分一致优于二维单次激发屏气图像。
  • 呼吸触发压缩感知三维除模糊外所有评分均优于屏气压缩感知三维。
  • 胆总管对比度以呼吸触发压缩感知三维最高(0.91 ± 0.04),其次为屏气压缩感知三维(0.88 ± 0.05)和二维单次激发屏气(0.85 ± 0.06),单因素方差分析 P < 0.0001。
  • 胆总管线剖面斜率屏气压缩感知三维(37.91 ± 6.38%最大强度/mm)显著高于呼吸触发压缩感知三维(29.46 ± 8.17%最大强度/mm),与二维单次激发屏气(35.8 ± 12.30%最大强度/mm)相当,单因素方差分析 P = 0.017。

诊断标准与关键数值

  • 图像质量、模糊/运动伪影及胰胆管树结构辨识度采用4分法由2名放射科医师评分。
  • 客观分析采用感兴趣区测量胆总管与邻近组织对比度,并以线剖面斜率量化胆管边界信号强度增加。

临床应用与阅片要点

  • 屏气压缩感知三维可在17秒单次屏气内完成采集并提供诊断质量图像,适用于需快速检查的患者。
  • 呼吸触发压缩感知三维扫描时间为3分48秒,图像质量评分除模糊外优于屏气压缩感知三维。
  • 二维单次激发屏气扫描时间为1分12秒,图像质量评分低于压缩感知序列。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the image quality between compressed sensing (CS) 3D-magnetic resonance cholangiopancreatography (MRCP) using respiratory-triggered (RT) and breath-hold (BH) acquisitions and 2D single-shot breath-hold (SSBH) MRCP at 3 T MRI.

METHODS: 53 datasets were retrospectively assessed. 3D-MRCP with CS (RT-CS10, BH-CS24) and 2D-SSBH MRCP were acquired. Overall image quality, blurring/motion artifacts and discernibility of the pancreaticobiliary tree (PBT) structures were scored on a 4-point scale by 2 radiologists. The contrast ratio between the common bile duct and its adjacent tissue was measured by region-of-interest (ROI) analysis. Signal intensity increase at the boundaries of the ducts was quantified by line profiles to objectively characterize blurring and motion artifacts.

RESULTS: Total scan duration was 17 s for BH-CS24, 1m12 s for 2D-SSBH and 3m48 s for RT-CS10. Images acquired with CS were consistently rated superior in terms of image quality, background suppression, blurring and discernibility of PBT structures compared to 2D-SSBH images. RT-CS10 was superior to BH-CS24 for all ratings except for blurring. Objective analysis yielded the highest contrast ratio for RT-CS10 (0.91 ± 0.04) followed by BH-C24 (0.88 ± 0.05) and 2D-SSBH (0.85 ± 0.06); one-way ANOVA P < 0.0001. The line-profile slope through the CBD was significantly higher in BH-CS24 (37.91 ± 6.38% of maximum intensity/mm) compared to RT-CS10 (29.46 ± 8.17% of maximum intensity/mm) and on par with 2D-SSBH (35.8 ± 12.30% of maximum intensity/mm); one-way-ANOVA P = 0.017.

CONCLUSION: CS allows acquisition of volumetric image data with improved image quality compared to SSBH. CS24 yields substantial gains in acquisition speed while robust towards artifacts, enabling diagnostic image quality with a single breath-hold acquisition.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Lohöfer FK, Kaissis GA, Rasper M, et al. Magnetic resonance cholangiopancreatography at 3 Tesla: Image quality comparison between 3D compressed sensing and 2D single-shot acquisitions. Eur J Radiol. 2019. PMID: 31084759. doi:10.1016/j.ejrad.2019.04.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。