肝脏CT灌注:哪种延迟可降低辐射剂量并保持诊断准确性

Liver CT perfusion: which is the relevant delay that reduces radiation dose and maintains diagnostic accuracy?
PubMed 文献 · Eur Radiol · 2019-05-21

本研究对59例无基础肝病的结直肠癌患者行肝脏CT灌注,注射对比剂同时开始采集,比较引入不同扫描延迟后灌注参数与辐射剂量的变化。延迟≤4秒不改变灌注准确性但带来不必要剂量;延迟9秒可在辐射剂量降低约21%的同时不显著损失灌注准确性。

要点

  • 延迟≤4秒不改变灌注准确性,但给患者带来不必要的辐射剂量。
  • 延迟9秒开始采集可使辐射剂量降低约21%,灌注准确性无显著损失。
  • 延迟>10秒时门静脉血流和总肝血流等灌注参数不准确。

核心结论

  • 使用小于4秒的延迟不改变灌注准确性且带来不必要剂量;注射对比剂后9秒开始采集可使辐射剂量降低约21%,灌注准确性无显著损失。

研究设计与样本

  • 研究纳入59例(男34例、女25例,平均年龄68±12岁)无基础肝病的结直肠癌患者行肝脏CT灌注,采集与碘对比剂注射同时开始,计算血流和肝灌注指数并与引入可变扫描延迟后的同一检查比较,同时计算剂量长度乘积、CT剂量指数和有效剂量。

诊断标准与关键数值

  • 延迟分组为τ≤4秒、5秒≤τ≤9秒、τ≥10秒三组,对应辐射剂量节省分别≤9.5%、11.9%–21.4%、≥23.8%,灌注准确性分别为高、中、低。

临床应用与阅片要点

  • 单输入和动脉血流的绝对变化对延迟较不敏感,τ≤9秒时分别仅约1 ml/min/100 g和1%,而门静脉血流和总血流对延迟更敏感;延迟9秒开始采集可在辐射剂量降低约21%的同时保持灌注准确性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: High radiation dose during CT perfusion (CTp) studies contributes to prevent CTp application in daily clinical practice. This work evaluates the consequences of scan delay on perfusion parameters and provides guidelines to help reducing the radiation dose by choosing the most appropriate delay.

METHODS: Fifty-nine patients (34 men, 25 women; mean age 68 ± 12) with colorectal cancer, without underlying liver disease, underwent liver CTp, with the acquisition starting simultaneously with iodinated contrast agent injection. Blood flow (BF) and hepatic perfusion index (HPI) were computed on the acquired examinations and compared with those of the same examinations when a variable scan delay (τ) is introduced. Dose length product, CT dose index, and effective dose were also computed on original and delayed examinations.

RESULTS: Altogether, three groups of delays (τ ≤ 4 s, 5 s ≤ τ ≤ 9 s, τ ≥ 10 s) were identified, yielding increasing radiation dose saving (RDS) (RDS ≤ 9.5%, 11.9% ≤ RDS ≤ 21.4%, RDS ≥ 23.8%) and decreasing perfusion accuracy (high (τ ≤ 4 s), medium (5 s ≤ τ ≤ 9 s), low (τ ≥ 10 s)). In particular, single-input and arterial BF and HPI were more insensitive to delay as regards the absolute variations (only 1 ml/min/100 g and 1%, respectively, for τ ≤ 9 s), than portal and total BF.

CONCLUSION: Using delays lower than 4 s does not change perfusion accuracy and conveys unnecessary dose to patients. Conversely, starting the acquisition 9 s after contrast agent injection yields a RDS of about 21%, with no significant losses in perfusion accuracy.

KEY POINTS: • Scan delays lower than 4 s do not alter perfusion accuracy and deliver an unnecessary radiation dose to patients. • Radiation dose delivered to patients can be reduced by 21.4% by introducing a 9-s scan delay, while keeping accurate perfusion values. • Using scan delays higher than 10 s, some perfusion parameters (portal and total BF) were inaccurate.