健康儿童在1.5和3特斯拉下肝脏、胰腺和脾脏的磁共振T1弛豫时间

Magnetic resonance imaging T1 relaxation times for the liver, pancreas and spleen in healthy children at 1.5 and 3 tesla.
PubMed 文献 · Pediatr Radiol · 2019-05-02

该研究前瞻性招募7至17岁健康儿童,在1.5或3T下进行腹部MRI T1 mapping,测量肝、胰、脾的T1弛豫时间。结果显示各器官T1值在1.5T与3T间不同,且与年龄、性别无显著统计学关联。作者报告了健康儿童上述器官的正常T1弛豫时间。

要点

  • 健康儿童肝脏T1值在1.5T为581±64 ms,3T为783±88 ms。
  • 健康儿童胰腺T1值在1.5T为576±55 ms,3T为730±30 ms。
  • 健康儿童脾脏T1值在1.5T为1,172±71 ms,3T为1,356±87 ms。

核心结论

  • 作者报告了健康儿童在1.5T和3T下肝脏、胰腺和脾脏的正常T1弛豫时间。

研究设计与样本

  • 机构审查委员会批准的前瞻性招募便利样本研究,纳入32名7至17岁健康儿童,于2018年2月至2018年10月期间进行腹部MRI(1.5T或3T),使用Modified Look-Locker序列进行T1 mapping。

诊断标准与关键数值

  • 肝脏T1弛豫时间:1.5T为581±64 ms,3T为783±88 ms。
  • 胰腺T1弛豫时间:1.5T为576±55 ms,3T为730±30 ms。
  • 脾脏T1弛豫时间:1.5T为1,172±71 ms,3T为1,356±87 ms。
  • 男性与女性之间T1值无统计学显著差异。
  • 在1.5T和3T场强下,线性回归显示年龄与肝脏、胰腺和脾脏T1值之间无显著关联。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: T1 relaxation time is a potential magnetic resonance imaging (MRI) biomarker for fibrosis and inflammation of the solid abdominal organs. However, normal T1 relaxation times of the solid abdominal organs have not been defined for children.

OBJECTIVE: The purpose of this study was to measure T1 relaxation times of the liver, pancreas and spleen in healthy children.

MATERIALS AND METHODS: This was an institutional review board-approved study of a convenience sample of prospectively recruited, healthy children ages 7 to 17 years undergoing research abdominal MRI (1.5 or 3 T) as part of a larger research study between February 2018 and October 2018. For the current study, T1 mapping was performed with a Modified Look-Locker sequence covering the upper abdomen. A single reviewer placed freehand regions of interest on the T1 parametric maps in the liver, pancreas and spleen, inclusive of as much parenchyma as possible. Student's t-tests and linear regression were used to compare T1 values by age and gender.

RESULTS: Thirty-two participants were included (16 female:16 male; mean age: 12.2±3.1 years; n=16 at 1.5 T). Median T1 relaxation times (ms) per organ were liver: 581±64 (1.5 T), 783±88 (3 T); pancreas: 576±55 (1.5 T), 730±30 (3 T), and spleen: 1,172±71 (1.5 T), 1,356±87 (3 T). T1 values were not statistically significantly different between males and females. At both 1.5 and 3 T field strengths, linear regression showed no significant association between age and T1 values for the liver, pancreas and spleen.

CONCLUSION: We report normal T1 relaxation times for the liver, pancreas and spleen at 1.5 and 3 T in a cohort of healthy children.

来源:Pediatr Radiol,查看原文。版权归原作者所有。