文献速递腹部介入CT

活体肝移植供者右后叶体积估算:基于门静脉分割的半自动CT体积测量

Estimation of the Right Posterior Section Volume in Live Liver Donors: Semiautomated CT Volumetry Using Portal Vein Segmentation.
PubMed 文献 · Acad Radiol · 2019-05-03

本研究纳入17例右后叶供肝的活体肝移植供者,回顾性比较基于门静脉分割的半自动CT体积测量(RPSVCTV)与基于标准肝体积和门静脉面积比值的体积测量(RPSVSLV)对术中实测重量的估算准确性。RPSVCTV与重量强相关(r=0.9414),且绝对差值和绝对百分比偏差均显著小于RPSVSLV。

要点

  • RPSVCTV与术中实测重量强相关(r=0.9414,p<0.0001),优于RPSVSLV(r=0.5899,p=0.0127)。
  • RPSVCTV的绝对差值(35.20±30.82)显著小于RPSVSLV(104.79±60.27),p=0.004。
  • 基于门静脉分割的半自动CT体积测量可用于活体供肝右后叶体积估算。

核心结论

  • 基于门静脉分割的半自动CT体积测量估算活体肝移植供者右后叶体积可行,其与术中实测重量强相关(r=0.9414;p<0.0001),且绝对差值小于基于标准肝体积和门静脉面积比值的测量方法。

研究设计与样本

  • 回顾性研究,纳入2003年4月至2016年8月本机构23例捐献右后叶供肝的活体供者中17例,纳入条件为肝获取前3个月内有CT扫描且门静脉解剖为I-III型;采用半自动CT体积测量(RPSVCTV)及标准肝体积与门静脉面积比值法(RPSVSLV)评估右后叶体积,以术中实测重量(W)为参考标准。

诊断标准与关键数值

  • RPSVCTV、RPSVSLV与W均值分别为503.4±97.8 mL(范围346.6-686.0)、516.54±146.20(范围274.06-776.32)、518.8±122.4(范围370.0-789.0);RPSVCTV与W相关系数r=0.9414(p<0.0001),RPSVSLV与W相关系数r=0.5899(p=0.0127);RPSVCTV与W的线性拟合方程为W = -74.7191 + 1.1791 RPSVCTV(R²=0.8862;p<0.001)。

临床应用与阅片要点

  • 作者认为基于门静脉分割的半自动CT体积测量可用于活体肝移植供者右后叶体积估算,RPSVCTV与术中实测重量强相关且绝对差值小于RPSVSLV。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To determine the accuracy of semiautomated CT volumetry using portal vein (PV) segmentation to estimate volume of the right posterior section (RPS) graft compared to intraoperative measured weight (W) in live liver donors.

MATERIALS AND METHODS: Among 23 donors who donated RPS grafts for liver transplantation in our institution from April 2003 to August 2016, 17 donors with CT scans within 3 months of liver procurement and PV anatomy of type I-III were included. RPS volumes were retrospectively evaluated by semiautomated CT volumetry (RPSVCTV) and by measurement of standard liver volume (SLV) and PV area ratio (RPSVSLV). RPS volumes were compared to W for correlation coefficients, (absolute) difference, and (absolute) percentage deviation. Linear fitting was performed to identify the method that yielded the greatest correlation with W.

RESULTS: Mean values of RPSVCTV, RPSVSLV, and W were 503.4 ± 97.8 mL (346.6-686.0), 516.54 ± 146.20 (274.06-776.32), and 518.8 ± 122.4 (370.0-789.0), respectively. RPSVCTV was strongly correlated with W (r = 0.9414; p < 0.0001), whereas RPSVSLV was only moderately did (r = 0.5899; p = 0.0127). RPSVCTV showed a significantly smaller absolute difference (35.20 ± 30.82 vs. 104.79 ± 60.27, p = 0.004) and absolute percentage deviation (6.61 ± 4.90 vs. 19.92 ± 10.37, p < 0.0001) from W. Equation correlating RPSVCTV and W was W = -74.7191 + 1.1791 RPSVCTV (R2 = 0.8862; p < 0.001).

CONCLUSION: RPSVCTV yields smaller absolute difference than RPSVSLV for estimating intraoperative measured weight of RPS in live liver donors. Semiautomated CT volumetry using PV segmentation is feasible for the estimation of the volume of the RPS of the liver, and RPSVCTV was strongly correlated with W (r = 0.9414; p < 0.0001).

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Jeong SY, Lee J, Kim KW, et al. Estimation of the Right Posterior Section Volume in Live Liver Donors: Semiautomated CT Volumetry Using Portal Vein Segmentation. Acad Radiol. 2019. PMID: 31060982. doi:10.1016/j.acra.2019.03.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。