CT与超声内镜鉴别5厘米以下胃肠道间质瘤与平滑肌瘤的比较
该研究纳入71例经病理证实的胃上皮下肿瘤患者,比较CT与超声内镜的诊断效能,并分析CT征象与胃肠道间质瘤诊断的关联。结果显示CT与超声内镜诊断效能相当,瘤内坏死和长径与短径比值小于1.5是诊断胃肠道间质瘤的独立CT征象。
要点
- CT诊断胃上皮下肿瘤(<5 cm)的敏感度84.5%、特异度53.8%、准确率78.9%,与超声内镜相当。
- 瘤内坏死(OR 10.88,p=0.037)和长径与短径比值<1.5(OR 32.37,p=0.002)是诊断胃肠道间质瘤的独立CT征象。
- 具有瘤内坏死或长径与短径比值<1.5的肿瘤可能需要进一步病理诊断。
核心结论
- 对于小于5 cm的胃上皮下肿瘤,CT诊断效能与超声内镜相当;瘤内坏死和长径与短径比值小于1.5可能与胃肠道间质瘤诊断相关,此类肿瘤可能需要进一步病理诊断。
研究设计与样本
- 研究纳入71例经病理证实的胃上皮下肿瘤患者,比较CT与超声内镜的诊断效能,并分析CT征象与胃肠道间质瘤诊断的关联。
关键影像表现/征象
- CT征象分析包括部位、长径、短径、长径与短径比值、轮廓、边缘、生长方式、强化程度和方式、衰减值、瘤内坏死、钙化、出血、表面凹陷及瘤周淋巴结。
- 多因素分析显示瘤内坏死(OR 10.88,p=0.037)和长径与短径比值小于1.5(OR 32.37,p=0.002)是诊断胃肠道间质瘤的独立CT征象。
诊断标准与关键数值
- 超声内镜诊断胃肠道间质瘤的敏感度77.6%、特异度61.5%、阳性预测值90.0%、阴性预测值38.1%、准确率74.6%。
- CT诊断胃肠道间质瘤的敏感度84.5%、特异度53.8%、阳性预测值89.1%、阴性预测值43.8%、准确率78.9%。
- 长径与短径比值小于1.5诊断胃肠道间质瘤的OR为32.37(p=0.002),瘤内坏死的OR为10.88(p=0.037)。
临床应用与阅片要点
- 对于小于5 cm的胃上皮下肿瘤,CT可作为与超声内镜相当的诊断方法。
- 阅片时注意评估瘤内坏死和长径与短径比值,二者与胃肠道间质瘤诊断独立相关。
- 具有瘤内坏死或长径与短径比值小于1.5的肿瘤可能需要进一步病理诊断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. Abdominal CT or endoscopic ultrasound is recommended for the evaluation of gastric subepithelial tumors. However, few studies have compared the diagnostic performance of these two methods. We compared the diagnostic performance of CT versus endoscopic ultrasound for gastric subepithelial tumors smaller than 5 cm. We also identified significant CT findings associated with the diagnosis of gastrointestinal stromal tumors. MATERIALS AND METHODS. Seventy-one patients with pathologically proven gastric subepithelial tumors were enrolled. We examined the diagnostic performance of CT compared with endoscopic ultrasound. We analyzed CT findings, including the location, long diameter (LD), short diameter (SD), LD-SD ratio, contour, margin, growth pattern, degree and pattern of enhancement, attenuation value, intralesional necrosis, calcification, hemorrhage, surface dimpling, and perilesional lymph node. RESULTS. Endoscopic ultrasound had a sensitivity of 77.6%, specificity of 61.5%, PPV of 90.0%, NPV of 38.1%, and accuracy of 74.6%. CT had a sensitivity of 84.5%, specificity of 53.8%, PPV of 89.1%, NPV of 43.8%, and accuracy of 78.9%. Multivariate analysis revealed that the presence of intralesional necrosis (odds ratio [OR], 10.88; p = 0.037) and an LD-SD ratio less than 1.5 (OR, 32.37; p = 0.002) were independent CT findings for the diagnosis of gastrointestinal stromal tumors. CONCLUSION. CT is as effective as endoscopic ultrasound for the diagnosis of gastric subepithelial tumors smaller than 5 cm. Tumors with intralesional necrosis and an LD-SD ratio less than 1.5 may require further pathologic diagnosis.
引用
- Huh CW, Jung DH, Kim JS, et al. CT Versus Endoscopic Ultrasound for Differentiating Small (2-5 cm) Gastrointestinal Stromal Tumors From Leiomyomas. AJR Am J Roentgenol. 2019. PMID: 31063418. doi:10.2214/AJR.18.20877
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。