传播显示法提高胰腺剪切波弹性成像的可重复性
本研究先用传播显示法在109例正常胰腺(NP)中评估剪切波弹性成像(SWE)测量胰腺弹性模量(PEM)的可重复性(1期),再据此测量慢性胰腺炎(CP,n=10)、导管内乳头状黏液性肿瘤(IPMN,n=31)和自身免疫性胰腺炎(AIP,n=5)的PEM(2期)。1期测量成功率93.9%(92/109例),NP的PEM中位数14.6 kPa,适宜测量次数至少3次;2期CP、IPMN和AIP的PEM中位数分别为19.6、18.1和17.2 kPa,NP与CP(p=0.0133)及NP与IPMN(p=0.0436)之间差异有统计学意义。
要点
- 传播显示法用于胰腺SWE时,正常胰腺测量成功率93.9%(92/109例)。
- 正常胰腺PEM中位数14.6 kPa,适宜SWE测量次数至少3次。
- CP、IPMN和AIP的PEM中位数分别为19.6、18.1和17.2 kPa。
核心结论
- 在SWE中使用传播显示法可提高胰腺弹性模量测量的可重复性。
研究设计与样本
- 分两期研究:1期在109例正常胰腺中确定测量成功率、重复测量的PEM中位数及适宜SWE测量次数;2期按1期确定的测量次数对CP(n=10)、IPMN(n=31)和AIP(n=5)测量PEM。
诊断标准与关键数值
- 1期正常胰腺测量成功率为93.9%(92/109例)。
- 正常胰腺PEM中位数为14.6 kPa,适宜SWE测量次数至少3次。
- 2期CP的PEM中位数为19.6 kPa,IPMN为18.1 kPa,AIP为17.2 kPa。
- NP与CP的PEM差异有统计学意义(p=0.0133),NP与IPMN的PEM差异有统计学意义(p=0.0436)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Evaluation of the pancreatic elastic modulus (PEM) using shear wave elastography (SWE) requires at least 5 measurements to ensure reproducibility. The aim of this study was to evaluate improvement in reproducibility of SWE, using the propagation display method in normal pancreas ([NP] phase 1) and to examine the differences in PEM between NP and chronic pancreatitis (CP), intraductal papillary mucinous neoplasm (IPMN) and autoimmune pancreatitis ([AIP] phase 2). In phase 1, the measurement success rate, median PEM in repeated measurements and appropriate number of SWE measurements were determined in 109 cases with NP. In phase 2, PEM was measured in CP (n = 10), IPMN (n = 31) and AIP (n = 5), using the required number of SWE measurements determined in phase 1. In phase 1, the measurement success rate was 93.9% (92/109 cases). The median PEM for NP was 14.6 kPa and the appropriate number of SWE measurements was at least 3. In phase 2, the median PEMs in CP, IPMN and AIP were 19.6, 18.1 and 17.2 kPa, respectively, with significant differences between NP and CP (p = 0.0133) and between NP and IPMN (p = 0.0436). Use of the propagation display method in SWE improves the reproducibility of measurement of PEM.
引用
- Hashizume K, Hirooka Y, Kawashima H, et al. The Propagation Display Method Improves the Reproducibility of Pancreatic Shear Wave Elastography. Ultrasound Med Biol. 2019. PMID: 31103347. doi:10.1016/j.ultrasmedbio.2019.04.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。