文献速递腹部MR

肝脏和脾脏磁共振弹性成像预测食管静脉曲张

Prediction of esophageal varices by liver and spleen MR elastography.
PubMed 文献 · Eur Radiol · 2019-04-30

本研究前瞻性评估磁共振弹性成像(MRE)测量的肝脏硬度(LSM)和脾脏硬度(SSM)对慢性肝病患者食管静脉曲张(EVs)的预测价值。211例患者分为训练组(n=140)和测试组(n=71),LSM(OR 2.362,95%CI 1.341-4.923,p=0.001)和SSM(OR 1.489,95%CI 1.095-2.235,p=0.010)是EVs的独立预测因素。基于两者构建的列线图在内部验证中C-index为0.942(95%CI 0.892-0.974),在测试组中C-index为0.948(95%CI 0.868-0.995),提示联合LSM和SSM可准确识别EVs风险患者。

要点

  • MRE测量的肝脏硬度(LSM)和脾脏硬度(SSM)均为食管静脉曲张的独立预测因素。
  • 联合LSM和SSM的列线图在训练组C-index为0.942,在测试组C-index为0.948。
  • MRE可无创评估食管静脉曲张的存在风险。

核心结论

  • 联合MRE测量的肝脏硬度和脾脏硬度是识别食管静脉曲张风险患者的准确工具。

研究设计与样本

  • 前瞻性研究,211例慢性肝病患者分为训练组(n=140)和测试组(n=71),使用MRE测量肝脏硬度(LSM)和脾脏硬度(SSM),并以内镜筛查食管静脉曲张作为参考标准。

诊断标准与关键数值

  • 训练组多因素回归显示LSM预测EVs的OR为2.362(95%CI 1.341-4.923,p=0.001),SSM的OR为1.489(95%CI 1.095-2.235,p=0.010);列线图内部验证C-index为0.942(95%CI 0.892-0.974),测试组C-index为0.948(95%CI 0.868-0.995)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: We aimed to assess the diagnostic performance of MR elastography (MRE) in predicting esophageal varices (EVs) in patients with chronic liver disease.

METHODS: We prospectively performed liver (LSM) and spleen stiffness measurements (SSM) using MRE and endoscopic screening for EVs to determine if patients with hepatocellular carcinoma were eligible for resection. We investigated whether LSM, SSM, and other non-invasive preoperative parameters were associated with the presence of EVs. In order to predict EVs, 211 patients were divided into training (n = 140) and test (n = 71) groups. A nomogram was built using independent factors based on logistic regression analysis in the training group and its accuracy was validated using an independent cohort.

RESULTS: Forty-six patients (21.8%) were diagnosed as having EVs (mild, n = 36; severe, n = 10). According to multiple regression analysis, LSM (odds ratio, 2.362; 95% confidence interval [CI], 1.341-4.923; p = 0.001) and SSM (1.489; 1.095-2.235; p = 0.010) were independent predictors of EVs in the training group. The nomogram showed good discrimination, with a C-index of 0.942 (95% CI, 0.892-0.974) through internal validation, and good calibration. Application of the nomogram in the test group still gave good discrimination (C-index, 0.948; 95% CI, 0.868-0.995).

CONCLUSIONS: The combination of LSM and SSM using MRE is an accurate tool to identify patients at risk for EVs.

KEY POINTS: • Performance of MR elastography can estimate the presence of esophageal varices non-invasively. • Liver and spleen stiffness measurements are independent predictors for esophageal varices. • The nomogram using a combination of liver and spleen stiffness measurements allows for the risk of esophageal varices.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Abe H, Midorikawa Y, Matsumoto N, et al. Prediction of esophageal varices by liver and spleen MR elastography. Eur Radiol. 2019. PMID: 31041563. doi:10.1007/s00330-019-06230-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。