三维脂肪饱和T1加权笛卡尔容积内插屏气检查(VIBE)诊断疑似大血管血管炎患者主动脉炎:与18F-FDG PET应用全整合PET/MRI的对比研究
回顾性纳入14例主动脉炎和14例18F-FDG PET阴性患者,在3T下用T1W VIBE序列评估4个主动脉段。以PET为标准,基于患者的敏感度85.7%、特异度100%、准确率92.9%,基于血管段的敏感度59.8%、特异度100%、准确率82.1%。T1W VIBE可诊断主动脉炎并可能辅助疑似大血管血管炎患者的管理。
要点
- 以18F-FDG PET为标准,T1W VIBE诊断主动脉炎基于患者的敏感度85.7%、特异度100%、准确率92.9%。
- 基于血管段分析,T1W VIBE敏感度59.8%、特异度100%、准确率82.1%。
- 图像质量和诊断置信度与PET血管壁摄取显著相关(r=0.763和0.679,p<0.0001)。
核心结论
- T1W 3D脂肪饱和VIBE MRI可诊断主动脉炎,并可能辅助疑似大血管血管炎患者的管理。
研究设计与样本
- 回顾性纳入14例主动脉炎和14例18F-FDG PET阴性患者,以PET为标准参考,在3T下用T1W VIBE增强前后成像评估4个主动脉段。
关键影像表现/征象
- 基于患者分析,T1W VIBE诊断主动脉炎的敏感度85.7%、特异度100%、阳性预测值100%、阴性预测值87.5%、准确率92.9%。
诊断标准与关键数值
- 基于血管段分析,T1W VIBE诊断主动脉炎的敏感度59.8%、特异度100%、阳性预测值100%、阴性预测值68%、准确率82.1%。
临床应用与阅片要点
- 图像质量和诊断置信度在所有检查中可接受至良好,观察者间对炎症活动度的一致性为中等(Cohen's k=0.69)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the feasibility of T1-weighted (T1W) three-dimensional (3D) fat saturated Cartesian volumetric interpolated breath-hold examination (VIBE) magnetic resonance imaging (MRI) sequence for the diagnosis of aortitis in patients with suspected large vessel vasculitis (LVV) applying fully integrated 2-[18F]-fluoro-2-deoxy-d-glucose (18F-FDG) positron-emission tomography (PET)/MRI.
MATERIAL AND METHODS: Fourteen patients with aortitis and 14 patients with a negative study for aortitis using 18F-FDG PET as the standard of reference for the evaluation of inflammatory aortic involvement were included retrospectively. All patients were imaged at 3 T using T1W VIBE pre- and post-contrast. Four aortic segments were evaluated for image quality (IQ), diagnostic confidence (DC), and the degree of inflammatory activity (IA) using a Likert scale. Binomial and generalised estimating equation model tests were used to assess the diagnostic performance of T1W VIBE. Cohen's k was applied to test for interobserver reproducibility with respect to IA. Spearman's rank correlation coefficient was calculated to examine correlations between IQ, DC, IA, and PET results.
RESULTS: On a patient- and segment-based analysis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 85.7% and 59.8%, 100% and 100%, 100% and 100%, 87.5% and 68%, and 92.9% and 82.1%, respectively. IQ and DC were acceptable to good in all examinations and substantial interobserver agreement was observed for IA (Cohen's k = 0.69). IQ and DC as well as IA and 18F-FDG vessel wall uptake were significantly correlated (r=0.763 and 0.679, respectively; p<0.0001).
CONCLUSION: T1W 3D fat saturated VIBE MRI allows diagnosis of aortitis and may aid in the management of patients with suspected LVV.
引用
- Einspieler I, Henninger M, Mergen V, et al. Three-dimensional fat-saturated T1-weighted Cartesian volumetric interpolated breath-hold examination (VIBE) for the diagnosis of aortitis in patients with suspected large vessel vasculitis: a comparative study with 18F-FDG PET applying fully integrated PET/MRI. Clin Radiol. 2019. PMID: 31130228. doi:10.1016/j.crad.2019.04.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。