文献速递胸部CT

层厚对CT最大与最小强度投影检测肺结节的影响

Effect of Slab Thickness on the Detection of Pulmonary Nodules by Use of CT Maximum and Minimum Intensity Projection.
PubMed 文献 · AJR Am J Roentgenol · 2019-05-07

回顾性分析221例肺结节患者的胸部CT数据,比较不同层厚最大强度投影(MIP)和最小强度投影(MinIP)图像对实性结节(SN)和亚实性结节(SSN)的检出率。10 mm MIP图像对SN检出率显著高于其他序列(阅片者1为84.5%,阅片者2为83.6%);3 mm MinIP图像对SSN检出率显著高于其他序列(除1 mm轴位外,阅片者1为93.3%,阅片者2为95.0%)。

要点

  • 10 mm MIP图像对实性结节(含<5 mm)检出率显著高于其他序列。
  • 3 mm MinIP图像对亚实性结节检出率显著高于其他序列(除1 mm轴位外)。
  • 不同序列间观察者间一致性均为好至优秀(κ≥0.687)。

核心结论

  • 10 mm MIP图像对检测实性结节极为高效;3 mm MinIP图像更有利于显示亚实性结节,其效率与1 mm轴位图像相当。

研究设计与样本

  • 回顾性分析221例肺结节患者的胸部CT数据;结节按密度分为实性结节(SN)和亚实性结节(SSN);由两名放射科医师独立评估1 mm和5 mm层厚轴位CT图像及MIP、MinIP图像;MIP图像用于SN检测,分别重建4种层厚(5、10、15、20 mm);MinIP图像用于SSN检测,分别重建3种层厚(3、8、15 mm)。

诊断标准与关键数值

  • 总SN及直径<5 mm的SN:10 mm MIP图像检出率阅片者1为84.5%和83.8%,阅片者2为83.6%和82.2%,显著高于其他序列。
  • 总SSN及<5 mm的SSN:3 mm MinIP图像检出率阅片者1为93.3%和78.6%,阅片者2为95.0%和81.0%,显著高于其他序列(除1 mm轴位外)。
  • 不同序列间观察者间一致性均为好至优秀(κ≥0.687)。

临床应用与阅片要点

  • 检测实性结节时可使用10 mm层厚MIP图像以提高检出率。
  • 显示亚实性结节时可使用3 mm层厚MinIP图像,其效率与1 mm轴位图像相当。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study was to investigate the effect of slab thickness on the detection of pulmonary nodules by use of maximum-intensity-projection (MIP) and minimum-intensity-projection (MinIP) to process CT images. MATERIALS AND METHODS. Chest CT data of 221 patients with pulmonary nodules were retrospectively analyzed. Nodules were categorized into two groups according to density: solid nodules (SNs) and subsolid nodules (SSNs). Pulmonary nodules were independently evaluated by two radiologists using axial CT images with 1-mm and 5-mm section thickness and MIP and MinIP images. MIP images for SN detection and MinIP images for SSN detection were separately reconstructed with four (5, 10, 15, 20 mm) and three (3, 8, 15 mm) slab thicknesses. The numbers and locations of detected nodules were recorded, and interobserver agreement was assessed. For each reader, the differences in nodule detection rates were evaluated in different series of images. RESULTS. Among the different series of images, interobserver agreements for detecting nodules were all good to excellent (κ ≥ 0.687). For total SNs and SNs with a diameter < 5 mm, detection rates on 10-mm MIP images were significantly higher than in other series of images (reader 1, 84.5% and 83.8%; reader 2, 83.6% and 82.2%). For total SSNs and SSNs < 5 mm, detection rates on 3-mm MinIP images were significantly higher than those in other series of images, except for 1-mm (reader 1, 93.3% and 78.6%; reader 2, 95.0% and 81.0%). CONCLUSION. Ten-millimeter MIP images are extremely efficient for detecting SNs. Three-millimeter MinIP images are more useful for visualizing SSNs, the efficiency being comparable to that achieved by use of 1-mm axial images.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Li WJ, Chu ZG, Zhang Y, et al. Effect of Slab Thickness on the Detection of Pulmonary Nodules by Use of CT Maximum and Minimum Intensity Projection. AJR Am J Roentgenol. 2019. PMID: 31063429. doi:10.2214/AJR.19.21325

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。