文献速递胸部CT

肺癌筛查报告与数据系统与泛加拿大肺癌早期检测结节风险计算在阿尔伯塔肺癌筛查研究中的应用比较

Application of Lung-Screening Reporting and Data System Versus Pan-Canadian Early Detection of Lung Cancer Nodule Risk Calculation in the Alberta Lung Cancer Screening Study.
PubMed 文献 · J Am Coll Radiol · 2019-05-15

在阿尔伯塔肺癌筛查研究的775例基线低剂量CT中,比较泛加拿大肺癌早期检测风险计算器(NRC分类)与ACR Lung-RADS对结节风险分类及早期召回率的表现。随访平均763天(±203天)检出肺癌22例(2.8%),两种方法敏感度、特异度及AUC无统计学显著差异,早期召回率分别为9.2%和9.3%;提高NRC磨玻璃结节阈值至20%或在Lung-RADS下对6-10mm实性结节应用5%阈值风险计算器可进一步降低早期召回率而不影响敏感度。

要点

  • NRC与Lung-RADS的敏感度、特异度及AUC无统计学显著差异,NRC有敏感度更高的趋势。
  • NRC和Lung-RADS的早期召回率分别为9.2%和9.3%,均显著低于国家肺癌筛查试验截断值下的召回率。
  • NRC不必要地召回部分磨玻璃结节,Lung-RADS召回较多恶性风险低的较小实性结节。

核心结论

  • 在本队列中NRC与Lung-RADS表现均很好,NRC有敏感度更高的趋势;两种方法早期召回率均低于10%,显著低于国家肺癌筛查试验截断值下的召回率;提高NRC磨玻璃结节阈值至20%或在Lung-RADS下对6-10mm实性结节应用5%阈值风险计算器可进一步降低早期召回率而不影响敏感度。

研究设计与样本

  • 阿尔伯塔肺癌筛查研究中对775例基线低剂量CT筛查采用泛加拿大肺癌早期检测风险计算器确定结节恶性风险,并按结节风险分类(NRC)类别和ACR Lung-RADS分类,比较各方法的检验性能特征和早期召回率,平均随访763天(±203天)。

关键影像表现/征象

  • NRC不必要地召回了部分磨玻璃结节。
  • Lung-RADS召回了许多恶性风险低的较小实性结节。

诊断标准与关键数值

  • NRC与Lung-RADS的敏感度、特异度及受试者工作特征曲线下面积无统计学显著差异。
  • NRC早期召回率为9.2%,Lung-RADS早期召回率为9.3%。
  • 提高NRC磨玻璃结节阈值至20%可进一步降低早期召回率而不影响敏感度。
  • 在Lung-RADS下对6-10mm实性结节应用5%阈值风险计算器可进一步降低早期召回率而不影响敏感度。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: False-positive scans and resultant needless early recalls can increase harms and reduce cost-effectiveness of low-dose CT (LDCT) lung cancer screening. How LDCT scans are interpreted and classified may impact these metrics.

METHODS: The Pan-Canadian Early Detection of Lung Cancer risk calculator was used to determine nodule risk of malignancy on baseline screening LDCTs in the Alberta Lung Cancer Screening Study, which were then classified according to Nodule Risk Classification (NRC) categories and ACR Lung Screening Reporting and Data System (Lung-RADS). Test performance characteristics and early recall rates were compared for each approach.

RESULTS: In all, 775 baseline screens were analyzed. After a mean of 763 days (±203) of follow-up, lung cancer was detected in 22 participants (2.8%). No statistically significant differences in sensitivity, specificity, or area under the receiver operator characteristic curve occurred between the NRC and Lung-RADS nodule management approaches. Early recall rates were 9.2% and 9.3% for NRC and Lung-RADS, with the NRC unnecessarily recalling some ground glass nodules, and the Lung-RADS recalling many smaller solid nodules with low risk of malignancy.

CONCLUSION: Performances of both the NRC and Lung-RADS in this cohort were very good with a trend to higher sensitivity for the NRC. Early recall rates were less than 10% with each approach, significantly lower than rates using the National Lung Screening Trial cutoffs. Further reductions in early recall rates without compromising sensitivity could be achieved by increasing the NRC threshold to 20% for ground glass nodules or by applying the nodule risk calculator with a 5% threshold to 6- to 10-mm solid nodules under Lung-RADS.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Tremblay A, Taghizadeh N, MacGregor JH, et al. Application of Lung-Screening Reporting and Data System Versus Pan-Canadian Early Detection of Lung Cancer Nodule Risk Calculation in the Alberta Lung Cancer Screening Study. J Am Coll Radiol. 2019. PMID: 31103442. doi:10.1016/j.jacr.2019.03.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。