文献速递胸部CTMRPET

孤立性肺结节:3T系统动态对比增强灌注MRI、动态对比增强ADCT与FDG-PET/CT在鉴别诊断和管理中定量能力的比较

Solitary pulmonary nodule: Comparison of quantitative capability for differentiation and management among dynamic CE-perfusion MRI at 3 T system, dynamic CE-perfusion ADCT and FDG-PET/CT.
PubMed 文献 · Eur J Radiol · 2019-03-28

前瞻性纳入57例患者共71个孤立性肺结节,比较超短TE动态对比增强灌注MRI、动态对比增强ADCT与FDG-PET/CT的鉴别诊断能力。ADCT与MRI总灌注的AUC分别为0.89和0.88,准确率均为87.3%,均显著高于系统性动脉灌注(77.5%)和SUVmax(78.9%)。结论认为两种灌注方法能力相似,均优于FDG-PET/CT。

要点

  • ADCT与MRI总灌注鉴别肺结节的AUC分别为0.89和0.88,准确率均为87.3%。
  • 总灌注准确率显著高于系统性动脉灌注(77.5%)和SUVmax(78.9%)。
  • 超短TE动态对比增强灌注MRI与ADCT定量能力相似,均优于FDG-PET/CT。

核心结论

  • 超短TE动态对比增强灌注MRI与ADCT具有相似的定量能力,在此场景下均优于FDG-PET/CT。

研究设计与样本

  • 前瞻性研究,纳入57例连续患者共71个结节,均行动态对比增强灌注ADCT、超短TE动态对比增强灌注MRI、FDG-PET/CT及微生物学和/或病理学检查。

关键影像表现/征象

  • 结节分为恶性45个和良性26个。
  • 采用双输入最大斜率模型测定肺动脉灌注、系统性动脉灌注和总灌注,PET/CT测定SUVmax。

诊断标准与关键数值

  • ADCT总灌注AUC为0.89,MRI总灌注AUC为0.88,均显著大于系统性动脉灌注和MRI的相应值(p<0.05)。
  • ADCT总灌注准确率87.3%(62/71),MRI总灌注准确率87.3%(62/71)。
  • 系统性动脉灌注准确率77.5%(55/71),与总灌注相比p=0.02。
  • SUVmax准确率78.9%(56/71),与总灌注相比p=0.03。

临床应用与阅片要点

  • 动态对比增强灌注ADCT和超短TE灌注MRI的总灌注参数可用于孤立性肺结节的鉴别诊断。
  • 总灌注的鉴别准确率高于系统性动脉灌注和FDG-PET/CT的SUVmax。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To prospectively compare the capability of dynamic first-pass contrast-enhanced (CE) perfusion MR imaging with ultra-short TE and area-detector CT (ADCT), analyzed with the same mathematical methods, and that of FDG-PET/CT for diagnosis and management of solitary pulmonary nodules (SPNs).

METHODS AND MATERIALS: Our institutional review board approved this study and written informed consent was obtained from all subjects. A total 57 consecutive patients with 71 nodules prospectively underwent dynamic CE-perfusion ADCT and MR imaging with ultra-short TE, FDG-PET/CT, as well as microbacterial and/or pathological examinations. The nodules were classified into malignant nodules (n = 45) and benign nodules (n = 26). Pulmonary arterial, systemic arterial and total perfusions were determined by means of dual-input maximum slope models on ADCT and MR imaging and maximum values of standard uptake values (SUVmax) on PET/CT. Receiver operating characteristic (ROC) analysis was performed for each index, and sensitivity, specificity and accuracy were compared by McNemar's test.

RESULTS: Areas under the curve (Azs) of total perfusion on ADCT (Az = 0.89) and MR imaging (Az = 0.88) were significantly larger than those of systemic arterial perfusion and MR imaging (p<0.05). Accuracy of total perfusion on ADCT (87.3% [62/71]) and MR imaging (87.3% [62/71]) was significantly higher than that of systemic arterial perfusion for both methods (77.5% [55/71] p = 0.02) and SUVmax (78.9% [56/71], p = 0.03).

CONCLUSION: Dynamic CE-perfusion MR imaging with ultra-short TE and ADCT and have similar potential capabilities, and are superior to FDG-PET/CT in this setting.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ohno Y, Fujisawa Y, Yui M, et al. Solitary pulmonary nodule: Comparison of quantitative capability for differentiation and management among dynamic CE-perfusion MRI at 3 T system, dynamic CE-perfusion ADCT and FDG-PET/CT. Eur J Radiol. 2019. PMID: 31084755. doi:10.1016/j.ejrad.2019.03.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。