点扩散函数重建对68Ga-DOTATATE PET/CT定量成像参数的影响
研究纳入38例患者42次68Ga-DOTATATE PET/CT检查共125个病灶,比较点扩散函数(PSF)与非PSF重建的定量参数。PSF使SUVmax和SUVpeak升高,肿瘤生长抑素受体表达异质性降低,对MTV和总病灶生长抑素亲和力的影响随病灶大小而异。
要点
- PSF重建使SUVmax平均升高27.5%、SUVpeak平均升高15.5%,报告SUV时需注明是否使用PSF。
- PSF使肿瘤生长抑素受体表达异质性平均降低7.1%,MTV平均降低18.6%。
- 病灶小于2 cm时PSF与非PSF的偏差大于2 cm及以上病灶,小病灶定量参数受重建方式影响更大。
核心结论
- PSF重建使SUVmax和SUVpeak升高、肿瘤生长抑素受体表达异质性降低,对MTV和总病灶生长抑素亲和力的影响随病灶大小而变化。
研究设计与样本
- 研究纳入38例患者共42次68Ga-DOTATATE PET/CT检查和125个病灶,分别采用PSF和非PSF重建,用组内相关系数和Bland-Altman分析比较两种重建的定量参数,并按病灶大小进行亚组分析。
关键影像表现/征象
- 125个病灶中51个位于肝脏、31个位于淋巴结、17个位于骨、8个位于胰腺、4个位于肺、14个位于其他部位。
诊断标准与关键数值
- PSF与非PSF的组内相关系数对SUVmax、SUVpeak、MTV和总病灶生长抑素亲和力为优(ICC=0.97-0.99),对肿瘤生长抑素受体表达异质性为好(ICC=0.81)。
- PSF与非PSF比较的平均偏差(平均百分比变化±标准差)为SUVmax 27.5%±14.7%、SUVpeak 15.5%±9.5%、MTV -18.6%±37.6%、总病灶生长抑素亲和力0.8%±28.1%、肿瘤生长抑素受体表达异质性-7.1%±11.0%。
- 病灶小于2 cm(n=75)时PSF与非PSF的相应偏差大于病灶2 cm及以上(n=50)者。
临床应用与阅片要点
- 同一患者随访比较定量参数时应使用相同重建方式(PSF或非PSF),避免因重建方式不同导致SUVmax和SUVpeak的偏差。
- 报告小病灶(小于2 cm)的生长抑素受体PET/CT定量参数时,需注意PSF与非PSF重建间的偏差大于2 cm及以上病灶。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The objective of our study was to investigate the impact of point-spread function (PSF) reconstruction and lesion size on 68Ga-tetraazacyclododecanetetraacetic acid-DPhe1-Tyr3-octreotate (DOTATATE) PET/CT quantitative parameters. MATERIALS AND METHODS. A total of 38 patients with 42 68Ga-DOTATATE PET/CT studies and 125 lesions were included. Scans were reconstructed with and without PSF modulation. For each lesion, the maximum standardized uptake value (SUVmax) and peak standardized uptake value (SUVpeak), metabolic tumor volume (MTV), total lesion somatostatin avidity, and tumor somatostatin receptor expression heterogeneity using the AUC method were measured. Intraclass correlation coefficient (ICC) and Bland-Altman analyses were used to compare PSF and non-PSF values. A subgroup analysis was performed to determine the impact of lesion size. RESULTS. Of the 125 lesions, 51 were in the liver, 31 in lymph nodes, 17 in bone, eight in pancreas, four in lung, and 14 in other sites. The ICCs between PSF and non-PSF values were excellent for SUVmax, SUVpeak, MTV, and total lesion somatostatin avidity (ICC = 0.97-0.99), and the ICC was good for tumor somatostatin receptor expression heterogeneity (ICC = 0.81). Comparison of PSF with non-PSF values showed a bias (mean percentage change ± SD) of 27.5% ± 14.7% for SUVmax, 15.5% ± 9.5% for SUVpeak, -18.6% ± 37.6% for MTV, 0.8% ± 28.1% for total lesion somatostatin avidity, and -7.1% ± 11.0% for tumor somatostatin receptor expression heterogeneity. Comparison of PSF with non-PSF values for lesions less than 2 cm (n = 75) showed corresponding biases greater than those for lesions 2 cm or larger (n = 50). CONCLUSION. PSF reconstruction effected higher values for SUVmax and SUVpeak, produced decreased values for tumor somatostatin receptor expression heterogeneity, and had a variable effect on MTV and total lesion somatostatin avidity depending on lesion size.