文献速递胸部CT

特发性肺纤维化中肺容积丢失的视觉与自动CT测量

Visual and Automated CT Measurements of Lung Volume Loss in Idiopathic Pulmonary Fibrosis.
PubMed 文献 · AJR Am J Roentgenol · 2019-05-07

本研究在273例特发性肺纤维化患者中评估CT肺容积标记与肺功能检查肺容积参数的关系。自动CT肺容积与总肺容量强相关(rP=0.92),手动CT测量与预测用力肺活量百分比显著相关,肺高度相关性最强(rP=0.44)。CT测量是肺容积的独立决定因素,不受纤维化和肺气肿影响。

要点

  • 自动CT肺容积与总肺容量强相关(rP=0.92;p<0.0005)。
  • 手动CT测量中肺高度与预测FVC百分比相关性最强(rP=0.44;p<0.0005)。
  • 所有手动CT测量观察者间一致性极好(ICC 0.82-0.96)。

核心结论

  • 自动和手动CT肺容积测量与肺功能检查肺容积参数显著相关,且独立于纤维化和肺气肿。

研究设计与样本

  • 在273例(男212例、女61例;中位年龄67岁)多学科诊断的特发性肺纤维化患者中评估CT肺容积标记与肺功能参数的关系;所有患者接受胸部无增强容积高分辨率CT;自动肺容积用商业软件提取;手动CT替代测量由两名评估者评估。

关键影像表现/征象

  • 手动CT替代测量包括肺高度、主动脉胸骨距离和斜裂回缩距离。
  • CT纤维化范围由两名观察者评分。
  • 自动CT肺容积与总肺容量强相关(rP=0.92;p<0.0005)。
  • 手动CT测量与预测FVC百分比显著相关,肺高度相关性最强(rP=0.44;p<0.0005)。
  • 多变量分析中,调整纤维化和肺气肿后,CT测量是肺容积的独立决定因素(R2=0.48;p<0.0005和p<0.003)。

诊断标准与关键数值

  • 自动CT肺容积与总肺容量强相关(rP=0.92;p<0.0005)。
  • 手动CT测量观察者间一致性极好(ICC 0.82-0.96)。
  • 肺高度与预测FVC百分比相关性最强(rP=0.44;p<0.0005)。
  • 多变量分析中CT测量独立决定肺容积(R2=0.48;p<0.0005和p<0.003)。

临床应用与阅片要点

  • CT肺容积测量(自动或手动)可作为特发性肺纤维化患者肺功能评估的辅助指标。
  • 手动CT测量中肺高度与预测FVC百分比相关性最强,阅片时可关注。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study is to establish the relationship between CT markers of lung volume and pulmonary function test (PFT) parameters of lung volume in idiopathic pulmonary fibrosis (IPF). MATERIALS AND METHODS. The relationships between PFT-derived parameters of lung volume (forced vital capacity [FVC] and total lung capacity [TLC]) and both CT-derived automated lung volume and manually derived surrogate measurements of lung volume on CT were evaluated in 273 patients (212 men and 61 women; median age, 67 years) with a multidisciplinary diagnosis of IPF. All patients underwent unenhanced volumetric high-resolution CT of the thorax. Automated lung volume was extracted using commercially available software. Three manual CT surrogate measurements of lung volume previously tested in the setting of radiation-induced lung fibrosis were evaluated by two raters. These measurements were lung height, aortosternal distance, and oblique fissure retraction distance. Fibrosis extent on CT was scored by two observers. Correlation coefficients and multivariable regression analyses were performed to assess the relationship between CT measurements and percentage of predicted FVC (hereafter referred to as "percentage FVC") and TLC. Interobserver agreement for CT markers was evaluated on the basis of the intraclass correlation coefficient. RESULTS. There was a strong correlation between CT-derived automated lung volume and TLC (rP = 0.92; p < 0.0005). There was excellent interobserver agreement for all manual CT measurements (intraclass correlation coefficient, 0.82-0.96). There were significant correlations between manual CT measurements and percentage FVC. Lung height had the strongest relationship with percentage FVC (rP = 0.44; p < 0.0005). In multivariable analysis, the CT measurements were independent determinants of lung volumes, after adjustment for fibrosis and emphysema (R2 = 0.48; p < 0.0005 and p < 0.003, respectively). Lung height had the most significant impact on the fit against lung volumes. CONCLUSION. Automated and manual CT measurements of lung volume are significantly related to PFT-derived parameters of lung volume, independent of fibrosis and emphysema.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Robbie H, Wells AU, Jacob J, et al. Visual and Automated CT Measurements of Lung Volume Loss in Idiopathic Pulmonary Fibrosis. AJR Am J Roentgenol. 2019. PMID: 31063425. doi:10.2214/AJR.18.20884

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。