本研究回顾性评估2009年7月至2015年8月接受VEPTR手术的胸廓功能不全综合征患儿,利用自由呼吸动态MRI在术前术后测量11项容积参数并与临床参数变化进行相关分析。术后左右肺潮气量分别增加43.8%和55.3%(P均<.001),右肺呼气末和吸气末容积分别增加22.9%(P=.001)和26.3%(P=.002),但临床参数术前术后无显著变化。胸腰段Cobb角对MRI潮气量预测能力差,辅助通气评级和用力肺活量与潮气量呈中度相关。

要点

  • VEPTR术后MRI示左、右肺潮气量分别增加43.8%和55.3%(P均<.001)。
  • 右肺呼气末和吸气末容积分别增加22.9%(P=.001)和26.3%(P=.002)。
  • 临床参数术前术后无显著变化,胸腰段Cobb角对MRI潮气量预测能力差。

核心结论

  • VEPTR手术与MRI所测潮气量各组成部分(左右胸壁、膈肌及左右肺潮气量)术后增加相关,但临床参数未显示术后潮气量改善。

研究设计与样本

  • 回顾性评估2009年7月至2015年8月胸廓功能不全综合征患儿的自由呼吸动态MRI图像,于VEPTR手术前后进行,从肺、胸壁和膈肌分割中导出11项容积参数,并与临床参数变化进行相关分析;采用配对Student t检验分析MRI参数和临床参数从术前到术后的变化是否具有统计学显著性。

关键影像表现/征象

  • 术后左、右肺吸气末和呼气末容积均显著增加,以右肺为著,呼气末增加22.9%(P=.001)、吸气末增加26.3%(P=.002)。
  • 术后左肺潮气量增加43.8%、右肺潮气量增加55.3%(P均<.001)。
  • 胸腰段Cobb角对MRI所测潮气量(胸壁、膈肌及左右肺分别)预测能力差。
  • 辅助通气评级和用力肺活量与潮气量(胸壁、膈肌及左右肺分别)呈中度相关。

临床应用与阅片要点

  • 定量动态MRI可用于显示VEPTR手术前后区域动态胸廓功能的变化,术后潮气量增加可见于左右胸壁、膈肌及左右肺各组成部分。
  • 临床参数(辅助通气评级、用力肺活量)与MRI潮气量仅呈中度相关,胸腰段Cobb角对MRI潮气量预测能力差。

局限性

  • 原文为回顾性评估。
  • 临床参数未显示术前术后显著变化,与MRI潮气量增加不一致。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Available methods to quantify regional dynamic thoracic function in thoracic insufficiency syndrome (TIS) are limited. Purpose To evaluate the use of quantitative dynamic MRI to depict changes in regional dynamic thoracic function before and after surgical correction of TIS. Materials and Methods Images from free-breathing dynamic MRI in pediatric patients with TIS (July 2009-August 2015) were retrospectively evaluated before and after surgical correction by using vertical expandable prosthetic titanium rib (VEPTR). Eleven volumetric parameters were derived from lung, chest wall, and diaphragm segmentations, and parameter changes before versus after operation were correlated with changes in clinical parameters. Paired analysis from Student t test on MRI parameters and clinical parameters was performed to detect if changes (from preoperative to postoperative condition) were statistically significant. Results Left and right lung volumes at end inspiration and end expiration increased substantially after operation in pediatric patients with thoracic insufficiency syndrome, especially right lung volume with 22.9% and 26.3% volume increase at end expiration (P = .001) and end inspiration (P = .002), respectively. The average lung tidal volumes increased after operation for TIS; there was a 43.8% and 55.3% increase for left lung tidal volume and right lung tidal volume (P < .001 for both), respectively. However, clinical parameters did not show significant changes from pre- to posttreatment states. Thoracic and lumbar Cobb angle were poor predictors of MRI tidal volumes (chest wall, diaphragm, and left and right separately), but assisted ventilation rating and forced vital capacity showed moderate correlations with tidal volumes (chest wall, diaphragm, and left and right separately). Conclusion Vertical expandable prosthetic titanium rib operation was associated with postoperative increases in all components of tidal volume (left and right chest wall and diaphragm, and left and right lung tidal volumes) measured at MRI. Clinical parameters did not demonstrate improvements in postoperative tidal volumes. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Paltiel in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Tong Y, Udupa JK, McDonough JM, et al. Quantitative Dynamic Thoracic MRI: Application to Thoracic Insufficiency Syndrome in Pediatric Patients. Radiology. 2019. PMID: 31112090. doi:10.1148/radiol.2019181731

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。