文献速递神经MR

源自时间分辨动态对比增强MR血管成像的急性缺血性卒中新型侧支成像方法:一项初步研究

A Novel Collateral Imaging Method Derived from Time-Resolved Dynamic Contrast-Enhanced MR Angiography in Acute Ischemic Stroke: A Pilot Study.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-05-16

本研究基于前瞻性登记的急性缺血性卒中患者数据,分析单侧颈内动脉和/或大脑中动脉M1段狭窄闭塞性病变患者的MR影像,利用动态对比增强MRA的动态信号生成多期MRA侧支图,并与基于动态磁敏感对比增强MR灌注生成的MRP侧支图进行对比。结果显示两种侧支图对侧支分级观察者间信度均优秀(加权κ分别为0.964和0.956),两种方法间一致性也优秀(加权κ=0.884;95%CI 0.819-0.949)。研究表明动态对比增强MRA的动态信号可用于生成多期侧支图像,提示多期MRA侧支图可能作为急性缺血性卒中有用的侧支成像方法。

要点

  • 动态对比增强MRA的动态信号可生成多期侧支图像,用于急性缺血性卒中侧支评估。
  • 多期MRA侧支图与MRP侧支图侧支分级一致性优秀(加权κ=0.884;95%CI 0.819-0.949)。
  • 多期MRA侧支图观察者间信度优秀(加权κ=0.964),与MRP侧支图(0.956)相当。

核心结论

  • 动态对比增强MRA的动态信号可用于生成多期侧支图像,提示多期MRA侧支图可能作为急性缺血性卒中有用的侧支成像方法。

研究设计与样本

  • 来自前瞻性登记的急性缺血性卒中注册研究,分析67例由单侧颈内动脉和/或大脑中动脉M1段狭窄闭塞性病变所致急性缺血性卒中患者的71对多期MRA侧支图和MRP侧支图;使用基于Matlab的院内程序生成两种侧支图并独立进行侧支评分,检验观察者间信度和方法间一致性。

诊断标准与关键数值

  • 多期MRA侧支图与MRP侧支图对侧支分级的观察者间信度分别为加权κ=0.964和0.956;两种侧支图间一致性加权κ=0.884(95%CI 0.819-0.949)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Assessment of the collateral status has been emphasized for appropriate treatment decisions in patients with acute ischemic stroke. The purpose of this study was to introduce a multiphase MRA collateral imaging method (collateral map) derived from time-resolved dynamic contrast-enhanced MRA and to verify the value of the multiphase MRA collateral map in acute ischemic stroke by comparing it with the multiphase collateral imaging method (MRP collateral map) derived from dynamic susceptibility contrast-enhanced MR perfusion.

MATERIALS AND METHODS: From a prospectively maintained registry of acute ischemic stroke, MR imaging data of patients with acute ischemic stroke caused by steno-occlusive lesions of the unilateral ICA and/or the M1 segment of the MCA were analyzed. We generated collateral maps using dynamic signals from dynamic contrast-enhanced MRA and DSC-MRP using a Matlab-based in-house program and graded the collateral scores of the multiphase MRA collateral map and the MRP collateral map independently. Interobserver reliabilities and intermethod agreement between both collateral maps for collateral grading were tested.

RESULTS: Seventy-one paired multiphase MRA and MRP collateral maps from 67 patients were analyzed. The interobserver reliabilities for collateral grading using multiphase MRA or MRP collateral maps were excellent (weighted κ = 0.964 and 0.956, respectively). The agreement between both collateral maps was also excellent (weighted κ = 0.884; 95% confidence interval, 0.819-0.949).

CONCLUSIONS: We demonstrated that the dynamic signals of dynamic contrast-enhanced MRA could be used to generate multiphase collateral images and showed the possibility of the multiphase MRA collateral map as a useful collateral imaging method in acute ischemic stroke.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Roh HG, Kim EY, Kim IS, et al. A Novel Collateral Imaging Method Derived from Time-Resolved Dynamic Contrast-Enhanced MR Angiography in Acute Ischemic Stroke: A Pilot Study. AJNR Am J Neuroradiol. 2019. PMID: 31097431. doi:10.3174/ajnr.A6068

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。