文献速递神经MR

3T下pH加权胺化学交换饱和转移回波平面成像与动态磁敏感对比灌注MRI评估人脑胶质瘤肿瘤酸性与富血供的关联

Association between Tumor Acidity and Hypervascularity in Human Gliomas Using pH-Weighted Amine Chemical Exchange Saturation Transfer Echo-Planar Imaging and Dynamic Susceptibility Contrast Perfusion MRI at 3T.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-05-16

这项回顾性研究纳入90例组织学确诊的胶质瘤患者,于2015至2018年间在3T下行pH加权胺化学交换饱和转移回波平面成像和动态磁敏感对比灌注MRI。结果显示,在T2高信号非强化肿瘤区,患者水平的中位CBV与3 ppm处磁化传递率不对称性显著相关(R=0.3180,P=.002),但在强化区无显著相关(P=.52)。高级别和IDH野生型胶质瘤中该正相关仍存在,而WHO II级或IDH突变肿瘤中未见。

要点

  • 在T2高信号非强化肿瘤区,患者水平中位CBV与3 ppm处MTR不对称性呈正相关(R=0.3180,P=.002)。
  • 在对比强化区,中位CBV与3 ppm处MTR不对称性无显著相关(P=.52)。
  • 高级别胶质瘤较底级别胶质瘤T2高信号肿瘤区3 ppm处MTR不对称性更高(P=.02)、MTR不对称性与CBV的体素水平相关性更强(P=.01)。

核心结论

  • 在T2高信号非强化肿瘤区,患者间CBV与酸性呈正线性相关,但在强化肿瘤区无此相关;单个肿瘤内存在局部异质性。

研究设计与样本

  • 回顾性研究,纳入90例组织学确诊的胶质瘤患者,扫描时间为2015至2018年,中位年龄50.3岁,男女比59:31;pH加权采用化学交换饱和转移回波平面成像估计3 ppm处磁化传递率不对称性,CBV采用动态磁敏感对比MRI估计。

关键影像表现/征象

  • 肿瘤内可见灌注升高与高酸性大致共定位,同时存在局部瘤内异质性。
  • 在T2高信号病灶内,患者水平中位CBV与3 ppm处磁化传递率不对称性显著相关(R=0.3180,P=.002)。
  • 在对比强化区域内,中位CBV与3 ppm处磁化传递率不对称性无显著相关(P=.52)。
  • T2高信号肿瘤内,高分级胶质瘤较低级别胶质瘤3 ppm处磁化传递率不对称性更高(P=.02),磁化传递率不对称性与CBV的体素水平Pearson相关性更强(P=.01)。
  • T2高信号肿瘤内,IDH野生型胶质瘤较IDH突变型胶质瘤3 ppm处磁化传递率不对称性更高(P=.04),磁化传递率不对称性与CBV的体素水平Pearson相关性更强(P=.01)。

诊断标准与关键数值

  • T2高信号病灶内患者水平中位CBV与3 ppm处磁化传递率不对称性相关:R=0.3180,P=.002。
  • 对比强化区域内患者水平中位CBV与3 ppm处磁化传递率不对称性相关:P=.52。
  • 高级别胶质瘤T2高信号病灶内患者水平中位CBV与3 ppm处磁化传递率不对称性相关:R=0.4128,P=.001。
  • IDH野生型胶质瘤T2高信号病灶内患者水平中位CBV与3 ppm处磁化传递率不对称性相关:R=0.4300,P=.002。

临床应用与阅片要点

  • 解读胶质瘤灌注与酸性成像时,应注意二者在T2高信号非强化区的一致性较好,而在强化区关联不显著。
  • 报告时应留意同一肿瘤内灌注与酸性的局部异质性,避免以单一区域代表全肿瘤。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Acidification of the tumor microenvironment from abnormal metabolism along with angiogenesis to meet metabolic demands are both hallmarks of malignant brain tumors; however, the interdependency of tumor acidity and vascularity has not been explored. Therefore, our aim was to investigate the association between pH-sensitive amine chemical exchange saturation transfer echoplanar imaging (CEST-EPI) and relative cerebral blood volume (CBV) measurements obtained from dynamic susceptibility contrast (DSC) perfusion MRI in patients with gliomas.

MATERIALS AND METHODS: In this retrospective study, 90 patients with histologically confirmed gliomas were scanned between 2015 and 2018 (median age, 50.3 years; male/female ratio = 59:31). pH-weighting was obtained using chemical exchange saturation transfer echo-planar imaging estimation of the magnetization transfer ratio asymmetry at 3 ppm, and CBV was estimated using DSC-MR imaging. The voxelwise correlation and patient-wise median value correlation between the magnetization transfer ratio asymmetry at 3 ppm and CBV within T2-hyperintense lesions and contrast-enhancing lesions were evaluated using the Pearson correlation analysis.

RESULTS: General colocalization of elevated perfusion and high acidity was observed in tumors, with local intratumor heterogeneity. For patient-wise analysis, median CBV and magnetization transfer ratio asymmetry at 3 ppm within T2-hyperintense lesions were significantly correlated (R = 0.3180, P = .002), but not in areas of contrast enhancement (P = .52). The positive correlation in T2-hyperintense lesions remained within high-grade gliomas (R = 0.4128, P = .001) and in isocitrate dehydrogenase wild-type gliomas (R = 0.4300, P = .002), but not in World Health Organization II or in isocitrate dehydrogenase mutant tumors. Both magnetization transfer ratio asymmetry at 3 ppm and the voxelwise correlation between magnetization transfer ratio asymmetry and CBV were higher in high-grade gliomas compared with low-grade gliomas in T2-hyperintense tumors (magnetization transfer ratio asymmetry, P = .02; Pearson correlation, P = .01). The same trend held when comparing isocitrate dehydrogenase wild-type gliomas and isocitrate dehydrogenase mutant gliomas (magnetization transfer ratio asymmetry, P = .04; Pearson correlation, P = .01).

CONCLUSIONS: A positive linear correlation between CBV and acidity in areas of T2-hyperintense, nonenhancing tumor, but not enhancing tumor, was observed across patients. Local heterogeneity was observed within individual tumors.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Wang YL, Yao J, Chakhoyan A, et al. Association between Tumor Acidity and Hypervascularity in Human Gliomas Using pH-Weighted Amine Chemical Exchange Saturation Transfer Echo-Planar Imaging and Dynamic Susceptibility Contrast Perfusion MRI at 3T. AJNR Am J Neuroradiol. 2019. PMID: 31097430. doi:10.3174/ajnr.A6063

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。