文献速递神经MRPET

磁共振波谱与¹¹C-蛋氨酸正电子发射断层成像联合用于准确诊断非强化幕上胶质瘤

Combination of Magnetic Resonance Spectroscopy and ¹¹C-Methionine Positron Emission Tomography for the Accurate Diagnosis of Non-Enhancing Supratentorial Glioma.
PubMed 文献 · Korean J Radiol · 2019-01-01

本研究纳入109例对比增强MRI上呈非强化幕上病变的患者,治疗前分别行MRS和¹¹C-MET PET检查,以病理或医学诊断标准为参考。MRS或¹¹C-MET PET任一达到诊断阈值即考虑胶质瘤,联合诊断的敏感度89.5%显著高于MRS单独60.0%(p<0.001)和¹¹C-MET PET单独75.8%(p=0.001),特异度无显著差异。

要点

  • 联合MRS与¹¹C-MET PET可将非强化幕上胶质瘤诊断敏感度从单 modality 的60.0%/75.8%提升至89.5%。
  • 联合诊断特异度42.9%,与MRS单独50.0%和¹¹C-MET PET单独50.0%相比无显著差异。
  • 任一 modality 达到诊断阈值即考虑胶质瘤的联合判读策略可提高敏感度。

核心结论

  • 联合MRS与¹¹C-MET PET可显著提高非强化幕上胶质瘤的准确诊断敏感度,且不显著降低特异度,提示该联合方法具有临床应用潜力。

研究设计与样本

  • 2012年2月至2017年12月纳入109例对比增强MRI上呈非强化幕上病变的患者,治疗前均行MRS和¹¹C-MET PET检查,以病理诊断或医学诊断标准为参考标准。

诊断标准与关键数值

  • MRS或¹¹C-MET PET任一结果达到诊断阈值即考虑为胶质瘤;MRS单独敏感度60.0%、特异度50.0%,¹¹C-MET PET单独敏感度75.8%、特异度50.0%,联合诊断敏感度89.5%、特异度42.9%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate whether the combination of magnetic resonance spectroscopy (MRS) and ¹¹C-methionine positron emission tomography (¹¹C-MET PET) could increase accurate diagnostic sensitivity for non-enhancing supratentorial gliomas.

MATERIALS AND METHODS: Between February 2012 and December 2017, 109 patients with non-enhanced supratentorial lesions on contrast-enhanced MRI were enrolled. Each patient underwent MRS and ¹¹C-MET PET before treatment. A lesion was considered to be a glioma when either the MRS or ¹¹C-MET PET results reached the diagnostic threshold. The radiological diagnosis was compared with the pathological diagnosis or medical diagnostic criteria.

RESULTS: The sensitivity and specificity were 60.0% and 50.0% for MRS and 75.8% and 50.0% for ¹¹C-MET PET, respectively. Upon combining the two modalities, the sensitivity and specificity of the imaging-based diagnosis prior to surgery reached 89.5% and 42.9%, respectively. Statistically significant differences in the sensitivities were observed between the combined and individual approaches (MRS alone, 89.5% vs. 60.0%, p < 0.001; ¹¹C-MET PET alone, 89.5% vs. 75.8%, p = 0.001). However, no significant differences in specificity were observed between the combined and individual modalities.

CONCLUSION: The combination of MRS and ¹¹C-MET PET findings significantly increases accurate diagnostic sensitivity for non-enhancing supratentorial gliomas without significantly lowering the specificity. This finding suggests the potential of the combined MRS and ¹¹C-MET PET approach in clinical applications.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Kudulaiti N, Qiu T, Lu J, et al. Combination of Magnetic Resonance Spectroscopy and ¹¹C-Methionine Positron Emission Tomography for the Accurate Diagnosis of Non-Enhancing Supratentorial Glioma. Korean J Radiol. 2019. PMID: 31132822. doi:10.3348/kjr.2018.0690

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。