文献速递神经头颈外周血管CT

细焦点技术在颈部CT血管成像中的效能

Efficacy of fine focal spot technique in CT angiography of neck.
PubMed 文献 · Br J Radiol · 2019-06-20

前瞻性研究纳入连续行颈部CT血管成像的成人患者,前4个月采用标准焦点(1×1 mm),后4个月采用细焦点(0.5×1 mm)。细焦点技术在血管清晰度和钙化伪影减少方面显著优于标准焦点,动脉搏动伪影无显著减少。

要点

  • 细焦点(0.5×1 mm)较标准焦点(1×1 mm)显著提高颈部CTA血管清晰度。
  • 细焦点显著减少血管壁钙化所致线束硬化伪影。
  • 细焦点对动脉搏动伪影无显著改善。

核心结论

  • 细焦点技术提高颈部CTA血管清晰度并减少钙化开花伪影,可能有助于评估动脉管腔狭窄和血管壁病变(包括斑块形态)。

研究设计与样本

  • 前瞻性研究,标准焦点组43例(平均年龄60岁,97个钙化动脉节段),细焦点组48例(平均年龄62岁,113个钙化动脉节段),连续纳入成人患者,两名盲法放射科医师采用5分法随机评估。

关键影像表现/征象

  • 30%患者存在>50%颈动脉狭窄。
  • 其余动脉未见闭塞或夹层。

诊断标准与关键数值

  • 采用5分法评估主动脉弓、头臂干、锁骨下动脉、颈总动脉、颈动脉分叉、颈内动脉、颈外动脉和椎动脉的血管清晰度、钙化及动脉搏动伪影。
  • 细焦点组血管清晰度显著优于标准焦点组(U=48238.50,p<.001,r=0.556)。
  • 细焦点组钙化伪影减少显著优于标准焦点组(U=2040.50,p<.001,r=0.564)。
  • 动脉搏动伪影无显著减少。

临床应用与阅片要点

  • 作者认为细焦点技术可能有助于评估动脉管腔狭窄和血管壁病变(包括斑块形态)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Focal spot size partially defines spatial resolution of a CT system. Many CT tubes have two focal spot sizes, with the finer one allowing more detailed imaging at the cost of photon intensity and increased heat production. Improved X-ray technology and advancement of various generations of iterative reconstruction allow the use of fine focal spot technique in CT angiography. CT neck angiography (CTNA) has been commonly performed as part of stroke imaging or in the trauma setting. This prospective study aimed to assess the efficacy of fine focal spot scanning in vessel clarity improvement, vessel calcification and arterial pulsation artefact reduction on CTNA.

METHODS AND MATERIALS: Consecutive adult patients of all ages and genders who presented for CTNA were included. All CTNA were scanned with standard focal spot size (SFSS) of 1 × 1 mm in first 4 months while the CTNA in the following 4 months with fine focal spot size (FFSS) of 0.5 × 1 mm. Vessel clarity, calcification and arterial pulsation artefact of arch of aorta, brachiocephalic, subclavian, common carotid, carotid bifurcation, internal carotid, external carotid and vertebral arteries were assessed randomly using a 5-point scale by two blinded radiologists. Results were compared.

RESULTS: There were 43 patients (mean age 60) with 97 calcified arterial segments in SFSS and 48 patients (mean age 62) with 113 calcified arterial segments in FFSS. 30 % of patients had > 50% carotid artery stenosis. No occlusion or dissection was found in the remaining arteries. Mann-Whitney test showed FFSS performed significantly better for vessel clarity (U: 48238.50, p < .001,r: 0.556) and calcification artefact reduction (U: 2040.50, p < .001,r: 0.564). There was no significant reduction for arterial pulsation artefact.

CONCLUSION: Fine focal spot technique improves vessel clarity and reduces calcification blooming artefact in CTNA. These benefits may potentially improve the assessment of arterial luminal stenosis and vessel wall pathology, including plaque morphology.

ADVANCES IN KNOWLEDGE: Beam hardening artefact from calcification particularly in the vessel wall can often reduce the clarity of vessel lumen thus affect accurate assessment of luminal stenosis. Fine focal spot technique has the advantages of reducing beam-hardening artefact of vessel wall calcifications and improving vessel wall clarity, thus it may potentially improve the assessment of arterial luminal stenosis and vessel wall pathology, including plaque morphology. It may become an important CT imaging technique in near future.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Oh LC, Lau KK, Devapalasundaram A, et al. Efficacy of fine focal spot technique in CT angiography of neck. Br J Radiol. 2019. PMID: 31112401. doi:10.1259/bjr.20190083

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。