文献速递神经外周血管MRDSA

静音磁共振血管成像在血流导向装置治疗颅内动脉瘤中的价值

Usefulness of Silent MR Angiography for Intracranial Aneurysms Treated with a Flow-Diverter Device.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-05-02

本研究纳入78例大型未破裂颈内动脉瘤患者,在血流导向装置置入6个月后同期行DSA、静音MRA与TOF-MRA复查,由2名神经外科医生和1名放射科医生独立盲法评分。静音MRA对载瘤动脉显示评分显著优于TOF-MRA(3.18±0.72 vs 2.31±0.86,P<.01),与DSA评估动脉瘤栓塞状态的一致率分别为91.0%和80.8%。作者认为静音MRA在显示血流导向装置内血流及评估动脉瘤栓塞状态方面优于TOF-MRA。

要点

  • 血流导向装置置入6个月后复查,静音MRA显示载瘤动脉评分显著优于TOF-MRA(3.18±0.72 vs 2.31±0.86,P<.01)。
  • 以DSA为参照,静音MRA评估动脉瘤栓塞状态一致率91.0%,TOF-MRA为80.8%。
  • 静音MRA可用于评估大型及巨大未破裂颈内动脉瘤血流导向装置置入后的状态。

核心结论

  • 与TOF-MRA相比,静音MRA能更好地显示血流导向装置内的血流图像,并可评估动脉瘤栓塞状态,适用于大型及巨大未破裂颈内动脉瘤血流导向装置置入后的评估。

研究设计与样本

  • 研究纳入78例患者共78个大型未破裂颈内动脉瘤,血流导向装置治疗6个月后同期行DSA、静音MRA和TOF-MRA复查;所有图像由2名神经外科医生和1名放射科医生独立阅片,载瘤动脉采用1分(不可见)至4分(极佳)的4分制评分,动脉瘤栓塞状态分为完全闭塞或不完全闭塞两档,以DSA为参照。

诊断标准与关键数值

  • 载瘤动脉显示采用4分制评分(1分不可见至4分极佳),静音MRA平均3.18±0.72,TOF-MRA平均2.31±0.86,静音MRA评分显著更高(P<.01)。以DSA为参照评估动脉瘤栓塞状态(完全闭塞或不完全闭塞),静音MRA一致率91.0%,TOF-MRA一致率80.8%。

临床应用与阅片要点

  • 作者认为静音MRA在显示血流导向装置内血流方面优于TOF-MRA,并可评估动脉瘤栓塞状态,可用于大型及巨大未破裂颈内动脉瘤血流导向装置置入后的评估。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The flow-diverter device has been established as a treatment procedure for large unruptured intracranial aneurysms. The purpose of this study was to compare the usefulness of Silent MR angiography and time-of-flight MRA to assess the parent artery and the embolization state of the aneurysm after a flow-diverter placement.

MATERIALS AND METHODS: Seventy-eight large, unruptured internal carotid aneurysms in 78 patients were the subjects of this study. After 6 months of treatment, they underwent follow-up digital subtraction angiography, Silent MRA, and TOF-MRA, performed simultaneously. All images were independently reviewed by 2 neurosurgeons and 1 radiologist and rated on a 4-point scale from 1 (not visible) to 4 (excellent) to evaluate the parent artery. The aneurysmal embolization status was assessed with 2 ratings: complete or incomplete occlusion.

RESULTS: The mean scores of Silent MRA and TOF-MRA regarding the parent artery were 3.18 ± 0.72 and 2.31 ± 0.86, respectively, showing a significantly better score with Silent MRA (P < .01). In the assessment of the embolization of aneurysms on Silent MRA and TOF-MRA compared with DSA, the percentages of agreement were 91.0% and 80.8%, respectively.

CONCLUSIONS: Silent MRA is superior for visualizing blood flow images inside flow-diverter devices compared with TOF-MRA. Furthermore, Silent MRA enables the assessment of aneurysmal embolization status. Silent MRA is useful for assessing the status of large and giant unruptured internal carotid aneurysms after flow-diverter placement.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Oishi H, Fujii T, Suzuki M, et al. Usefulness of Silent MR Angiography for Intracranial Aneurysms Treated with a Flow-Diverter Device. AJNR Am J Neuroradiol. 2019. PMID: 31048297. doi:10.3174/ajnr.A6047

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。