回波平面FLAIR序列改善胎儿脑MRI中板下层的显示
研究连续纳入2014年1月至2018年3月间胎儿脑MRI检查,比较T2加权单次激发快速自旋回波(SSFSE)与回波平面成像(EPI)FLAIR序列对脑分层的显示。EPI-FLAIR在多个脑叶对板下层的识别优于SSFSE,板下层与中间带信号强度比更高,读者间一致性也更高。
要点
- EPI-FLAIR显示板下层(完全+部分)在额叶、颞叶、顶叶、枕叶均优于T2-SSFSE。
- EPI-FLAIR的板下层与中间带信号强度比高于T2-SSFSE,有助于区分二者。
- EPI-FLAIR的读者间一致性κ值高于T2-SSFSE。
核心结论
- 回波平面FLAIR序列较T2加权单次激发快速自旋回波序列改善了胎儿脑分层的显示,经定量和定性方法证实。
研究设计与样本
- 连续性胎儿脑MRI检查的影像学对比研究,纳入259例进行定性分析、72例进行定量分析,由两名神经放射科医生采用三点分级法评估脑层可见性,并以配对t检验比较信号强度比、加权κ评估读者一致性。
关键影像表现/征象
- 板下层识别(完全+部分)EPI-FLAIR额叶n=243 vs T2-SSFSE n=117,颞叶n=244 vs n=137,顶叶n=240 vs n=93,枕叶n=241 vs n=97,均P<.001。
- 板下层与中间带信号强度比EPI-FLAIR为1.6-2.1,T2-SSFSE为1.2-1.2,所有脑叶均P<.001。
- 读者间一致性EPI-FLAIR κ=0.91-0.95,T2-SSFSE κ=0.80-0.87。
诊断标准与关键数值
- 板下层可见性采用三点分级系统(完全、部分、不可见)评估。
- 定量分析计算相邻脑区信号强度比,包括板下层与中间带、板下层与皮质板。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background The cortical plate (future cortex) is readily identifiable in utero at MRI. However, MRI evaluation of the remaining brain layers is limited by the poor T2 contrast between the subplate and the underlying intermediate zone (IZ). Purpose To compare the delineation of fetal brain lamination between T2-weighted single-shot fast spin-echo (SSFSE) and echo-planar imaging (EPI) fluid-attenuated inversion recovery (FLAIR) images, and to quantify differences in the depiction of brain layering between the two sequences. Materials and Methods Consecutive fetal brain MRI examinations performed between January 2014 and March 2018 with T2-weighted SSFSE and EPI-FLAIR images were reviewed. Two neuroradiologists evaluated the visibility of brain layers by using a three-point grading system, and findings were compared by using the sign test. One rater performed region-of-interest analysis in the cortical plate (CP), subplate (gyral crest and sulcal bottom), and IZ. Signal intensity (SI) ratios between adjacent brain compartments were calculated and compared by using the paired t test. Reader agreement was assessed by using weighted κ values. Results A total of 259 MRI examinations (mean gestational age [GA], 26.9 weeks ± 5.6) were included in the qualitative analysis, and 72 MRI examinations (mean GA, 27.4 weeks ± 5.5) were included in the quantitative analysis. Subplate identification on EPI-FLAIR images was superior to that on T2-weighted SSFSE images (subplate visualization [complete + partial]: frontal lobe, n = 243 vs n = 117; temporal lobe, n = 244 vs n = 137; parietal lobe n = 240 vs n = 93; and occipital lobe, n = 241 vs n = 97, respectively; P < .001), with higher interrater reliability (κ = 0.91-0.95 for EPI-FLAIR images and 0.80-0.87 for T2-weighted SSFSE images). SI ratios between the IZ and subplate were significantly higher on EPI-FLAIR images in all lobes (EPI-FLAIR images: 1.6-2.1; T2-weighted SSFSE images:1.2-1.2; P < .001). Subplate-to-CP ratios were not statistically significant between the two sequences (EPI-FLAIR:1.8-2.4; T2-weighted SSFSE: 2.0-2.2; P < .001). Conclusion The echo-planar fluid-attenuated inversion recovery sequence improves visualization of fetal brain lamination compared with the T2-weighted single-shot fast spin-echo sequence, as established by quantitative and qualitative methods. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Rossi in this issue.
引用
- Diogo MC, Prayer D, Gruber GM, et al. Echo-planar FLAIR Sequence Improves Subplate Visualization in Fetal MRI of the Brain. Radiology. 2019. PMID: 31084478. doi:10.1148/radiol.2019181976
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。