文献速递神经头颈MR

垂体大腺瘤肿瘤质地术前评估:基于常规T2加权MRI的机器学习直方图分析

Preoperative evaluation of tumour consistency in pituitary macroadenomas: a machine learning-based histogram analysis on conventional T2-weighted MRI.
PubMed 文献 · Neuroradiology · 2019-04-22

回顾性纳入55例垂体大腺瘤(硬13例、软42例),从冠状位T2加权MRI提取直方图特征,用人工神经网络分类并与信号强度比(SIR)评估比较。直方图分析AUC为0.710、准确率72.5%,SIR的AUC为0.551、准确率74.5%,直方图分析AUC优于SIR评估(p=0.021)。

要点

  • 基于T2加权MRI的机器学习直方图分析预测垂体大腺瘤质地的AUC为0.710。
  • 信号强度比(SIR)评估的AUC为0.551,低于直方图分析(p=0.021)。
  • 直方图分析准确率72.5%,SIR评估准确率74.5%。

核心结论

  • 基于机器学习的T2加权MRI直方图分析可能有助于预测垂体大腺瘤的质地,其预测性能优于SIR评估。

研究设计与样本

  • 回顾性研究纳入55例垂体大腺瘤患者(硬13例、软42例),参考标准为手术及组织病理学所见。
  • 从冠状位T2加权MRI原始、滤波及变换图像经手动分割提取直方图特征,机器学习分类器为人工神经网络(ANN)。
  • 为平衡类别(硬38例 vs 软42例),从硬质地垂体大腺瘤的不同层面获取多个样本。

诊断标准与关键数值

  • 直方图分析:ANN正确分类72.5%的垂体大腺瘤,AUC为0.710。
  • SIR评估:准确率74.5%,AUC为0.551。
  • AUC比较:直方图分析优于SIR评估(z=2.312,p=0.021)。
  • 162个特征中仅137个具有极好可重复性;共线性分析得到20个特征;特征选择算法提供6个纹理特征。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the potential value of machine learning (ML)-based histogram analysis (or first-order texture analysis) on T2-weighted magnetic resonance imaging (MRI) for predicting consistency of pituitary macroadenomas (PMA) and to compare it with that of signal intensity ratio (SIR) evaluation.

METHODS: Fifty-five patients with 13 hard and 42 soft PMAs were included in this retrospective study. Histogram features were extracted from coronal T2-weighted original, filtered and transformed MRI images by manual segmentation. To achieve balanced classes (38 hard vs 42 soft), multiple samples were obtained from different slices of the PMAs with hard consistency. Dimension reduction was done with reproducibility analysis, collinearity analysis and feature selection. ML classifier was artificial neural network (ANN). Reference standard for the classifications was based on surgical and histopathological findings. Predictive performance of histogram analysis was compared with that of SIR evaluation. The main metric for comparisons was the area under the receiver operating characteristic curve (AUC).

RESULTS: Only 137 of 162 features had excellent reproducibility. Collinearity analysis yielded 20 features. Feature selection algorithm provided six texture features. For histogram analysis, the ANN correctly classified 72.5% of the PMAs regarding consistency with an AUC value of 0.710. For SIR evaluation, accuracy and AUC values were 74.5% and 0.551, respectively. Considering AUC values, ML-based histogram analysis performed better than SIR evaluation (z = 2.312, p = 0.021).

CONCLUSION: ML-based T2-weighted MRI histogram analysis might be a useful technique in predicting the consistency of PMAs, with a better predictive performance than that of SIR evaluation.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Zeynalova A, Kocak B, Durmaz ES, et al. Preoperative evaluation of tumour consistency in pituitary macroadenomas: a machine learning-based histogram analysis on conventional T2-weighted MRI. Neuroradiology. 2019. PMID: 31011772. doi:10.1007/s00234-019-02211-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。