低剂量对比剂肾灌注CT的图像质量与辐射剂量:与320排系统常规CT的比较

Image quality and radiation dose of renal perfusion CT with low-dose contrast agent: a comparison with conventional CT using a 320-row system.
PubMed 文献 · Clin Radiol · 2019-04-20

本研究比较低剂量对比剂(40 ml)灌注CT与常规320排CT对肾脏肿瘤的评估,28例接受常规CT、26例接受灌注CT。灌注CT图像噪声更高、整体图像质量更低,但动脉显示评分更高,皮髓质交界锐利度及肿瘤检出敏感度与阳性预测值相当,辐射剂量指标显著更低。

要点

  • 低剂量对比剂灌注CT的动脉显示评分显著高于常规CT,皮髓质交界锐利度与常规CT相当。
  • 灌注CT图像噪声高于常规CT,整体图像质量低于常规CT。
  • 灌注CT的CTDI、DLP、SSDE均显著低于常规CT。

核心结论

  • 使用低剂量对比剂(40 ml)的灌注CT在图像质量下降和噪声增加的情况下,仍保留了动脉显示和肿瘤检出率,并实现了低辐射剂量。

研究设计与样本

  • 对比研究:28例患者接受常规CT(C-CT),26例患者接受低剂量(40 ml)对比剂灌注CT,采用320排CT系统,比较图像质量主观评分、肿瘤检出率及定量参数与辐射剂量指标。

关键影像表现/征象

  • 灌注CT图像噪声高于常规CT,整体图像质量低于常规CT。
  • 灌注CT动脉显示评分显著高于常规CT,皮髓质交界锐利度评分两者相当。
  • 左右肾动脉对比噪声比(CNR)在灌注CT上均显著高于常规CT。

诊断标准与关键数值

  • 图像噪声、动脉显示、皮髓质交界锐利度及整体图像质量均采用四级评分法评估。
  • 病灶<4 cm(n=66)的肿瘤检出率:两种技术敏感度与阳性预测值相当。

临床应用与阅片要点

  • 灌注CT使用40 ml低剂量对比剂即可获得优于常规CT的动脉显示评分和相当的皮髓质交界锐利度。
  • 灌注CT图像噪声较高、整体图像质量较低,阅片时需注意噪声对图像质量的影响。
  • 灌注CT的CTDI、DLP、SSDE显著低于常规CT,有利于降低辐射剂量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To compare perfusion computed tomography (CT) with reconstructed image from source data using low-dose contrast agent and conventional 320-row CT for the evaluation of renal tumours.

MATERIALS AND METHODS: Twenty-eight patients underwent conventional CT (C-CT) and 26 patients underwent perfusion CT with low-dose (40 ml) contrast agent. Image noise, arterial visualisation, the sharpness of the corticomedullary junction (CMJ), and overall image quality were each assessed using a four-point scale. The tumour detection rate for lesions <4 cm (n=66) was also evaluated. Quantitative image parameters including image noise and the contrast-to-noise ratios (CNRs) of the renal artery and CMJ were measured. The volume CT dose index (CTDI), dose-length product (DLP), and size-specific dose estimate (SSDE) were also recorded.

RESULTS: Although the image noise of perfusion CT was higher than that of C-CT and the overall image quality of perfusion CT was lower than that of C-CT, the arterial visualisation score of perfusion CT was significantly higher than that of C-CT. The CMJ sharpness scores of the two techniques were equivalent. Sensitivity and positive predictive values were also equivalent with respect to tumour detection. The CNRs of both the left and right renal arteries were significantly higher on perfusion CT than on C-CT. The CTDI, DLP, and SSDE of perfusion CT were significantly lower than those of C-CT.

CONCLUSION: Perfusion CT using low-dose contrast agent preserved arterial visualisation and the tumour detection rate and achieved a low radiation dose despite image quality degradation and image noise.