文献速递骨肌腹部技术与安全CT

利用深度学习分割级联在CT中模拟双能X线吸收测定法

Simulating Dual-Energy X-Ray Absorptiometry in CT Using Deep-Learning Segmentation Cascade.
PubMed 文献 · J Am Coll Radiol · 2019-04-12

本研究利用机器学习算法从常规腹部和盆腔CT中模拟腰椎DEXA评分,训练和验证使用1,843对CT与DEXA结果(间隔6个月内)。算法检测骨质疏松或骨量减少的敏感度为84.4%(95%CI 82.3%-86.2%),特异度为72.7%(95%CI 67.7%-77.2%),准确率82%。作者认为该算法能以高准确度和少量假阳性识别骨质疏松和骨量减少。

要点

  • 算法从常规CT模拟腰椎DEXA评分,检测骨质疏松或骨量减少敏感度84.4%、特异度72.7%。
  • 准确率82%,假阳性92例、假阴性212例。
  • 作者认为该算法能以高准确度和少量假阳性识别骨质疏松和骨量减少。

核心结论

  • 该算法能以82%的准确度和少量假阳性识别骨质疏松和骨量减少;利用机器学习从现有数据中挖掘更多信息可能对骨密度筛查等群体健康工作产生显著影响。

研究设计与样本

  • 研究使用2010年1月至2014年9月间610例腹部和盆腔CT开发脊柱和L1-L4多类分割;DEXA模拟训练和验证使用1,843对CT与同一人6个月内DEXA结果;采用机器学习回归确定计算分级(基于L1-L4椎体)与DEXA t值的相关性。

诊断标准与关键数值

  • 算法生成的t值等效值分析显示真阳性1,144例、假阳性92例、真阴性245例、假阴性212例,准确率82%;检测骨质疏松或骨量减少的敏感度84.4%(95%CI 82.3%-86.2%),特异度72.7%(95%CI 67.7%-77.2%)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Osteoporosis is an underdiagnosed condition despite effective screening modalities. Dual-energy x-ray absorptiometry (DEXA) screening, although recommended in clinical guidelines, remains markedly underutilized. In contrast to DEXA, CT utilization is high and presents a valuable data source for opportunistic osteoporosis screening. The purpose of this study was to describe a method to simulate lumbar DEXA scores from routinely acquired CT studies using a machine-learning algorithm.

METHODS: Between January 2010 and September 2014, 610 CT studies of the abdomen and pelvis were used to develop spinal column and L1 to L4 multiclass segmentation. DEXA simulation training and validation used 1,843 pairs of CT studies accompanied by DEXA results obtained within a 6-month interval from the same individual. Machine learning-based regression was used to determine correlation between calculated grade (on the basis of vertebrae L1-L4) and DEXA t score.

RESULTS: Analysis of the t score equivalent, generated by the algorithm, revealed true positives in 1,144 patients, false positives in 92 patients, true negatives in 245 patients, and false negatives in 212 patients, resulting in an accuracy of 82%. Sensitivity for the detection of osteoporosis or osteopenia was 84.4% (95% confidence interval, 82.3%-86.2%), and specificity was 72.7% (95% confidence interval, 67.7%-77.2%).

CONCLUSIONS: The presented algorithm can identify osteoporosis and osteopenia with a high degree of accuracy (82%) and a small proportion of false positives. Efforts to cull greater information using machine-learning algorithms from pre-existing data have the potential to have a marked impact on population health efforts such as bone mineral density screening for osteoporosis, in which gaps in screening currently exist.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Krishnaraj A, Barrett S, Bregman-Amitai O, et al. Simulating Dual-Energy X-Ray Absorptiometry in CT Using Deep-Learning Segmentation Cascade. J Am Coll Radiol. 2019. PMID: 30982683. doi:10.1016/j.jacr.2019.02.033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。