基于减影的径向采集逐点编码时间缩减MRA在支架辅助弹簧圈栓塞前循环动脉瘤随访中的应用
回顾性纳入25例前循环动脉瘤支架辅助弹簧圈栓塞患者,同次随访分别行TOF-MRA与PETRA qMRA,以最新DSA为参考。PETRA qMRA支架内血流显示评分显著高于TOF-MRA(P<.001),动脉瘤闭塞状态与DSA一致性更高(观察者1 92.0%、观察者2 88.0% vs TOF-MRA 76.0%、80.0%)。结论提示PETRA qMRA是此类患者有用的随访技术。
要点
- PETRA qMRA支架内血流显示评分显著高于TOF-MRA(两名观察者均P<.001)。
- PETRA qMRA评估动脉瘤闭塞状态与DSA一致性优于TOF-MRA。
- PETRA qMRA观察者间一致性良好(κ=0.63)。
核心结论
- PETRA qMRA是前循环动脉瘤支架辅助弹簧圈栓塞术后随访的有用技术。
研究设计与样本
- 回顾性评估25例(男3例、女22例;平均年龄59.1±14.0岁)前循环动脉瘤支架辅助弹簧圈栓塞患者。
- 同一随访 session 采集TOF-MRA与PETRA qMRA数据,以最新DSA为参考标准。
- 两名神经放射科医师独立阅片,对支架内血流及闭塞状态进行主观分级。
关键影像表现/征象
- PETRA qMRA支架内血流可视化平均评分显著高于TOF-MRA(两名观察者均P<.001)。
诊断标准与关键数值
- 支架内血流主观评分相对最新DSA表现分级,PETRA qMRA平均评分显著高于TOF-MRA(两名观察者均P<.001)。
- 动脉瘤闭塞状态分为完全闭塞或瘤颈/动脉瘤残留,PETRA qMRA与DSA一致性:观察者1 92.0%、观察者2 88.0%;TOF-MRA:观察者1 76.0%、观察者2 80.0%。
- PETRA qMRA观察者间一致性κ=0.63;DSA与PETRA qMRA的检查间一致性优于DSA与TOF-MRA。
临床应用与阅片要点
- 前循环动脉瘤支架辅助弹簧圈栓塞术后随访中,PETRA qMRA在支架内血流显示和闭塞状态评估方面可能优于TOF-MRA。
- 作者认为PETRA qMRA是此类患者随访的有用技术。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Time-of-flight MR angiography, though widely used after coil embolization, is associated with limitations owing to magnetic susceptibility and radiofrequency shielding following stent-assisted coil embolization. We evaluated the pointwise encoding time reduction with radial acquisition (PETRA) sequence in subtraction-based MRA (qMRA) using an ultrashort TE relative to TOF-MRA during the follow-up of stent-assisted coil embolization for anterior circulation aneurysms.
MATERIALS AND METHODS: Twenty-five patients (3 men and 22 women; mean age, 59.1 ± 14.0 years) underwent stent-assisted coil embolization for anterior circulation aneurysms and were retrospectively evaluated using TOF-MRA and PETRA qMRA data from the same follow-up session. Two neuroradiologists independently reviewed both MRA findings and subjectively graded flow within the stents (relative to the latest DSA findings) and occlusion status (complete occlusion or neck/aneurysm remnant). Interobserver and intermodality agreement for TOF-MRA and PETRA qMRA were evaluated.
RESULTS: The mean score for flow visualization within the stents was significantly higher in PETRA qMRA than in TOF-MRA (P < .001 for both observers), and good interobserver agreement was reported (κ = 0.63). The aneurysm occlusion status of PETRA qMRA (observer 1, 92.0%; observer 2, 88.0%) was more consistent with DSA than with TOF-MRA (observer 1, 76.0%; observer 2, 80.0%), and there was a better intermodality agreement between DSA and PETRA qMRA than between DSA and TOF-MRA.
CONCLUSIONS: These findings indicate that PETRA qMRA is a useful follow-up technique for patients who have undergone stent-assisted coil embolization for anterior circulation aneurysms.
引用
- Heo YJ, Jeong HW, Baek JW, et al. Pointwise Encoding Time Reduction with Radial Acquisition with Subtraction-Based MRA during the Follow-Up of Stent-Assisted Coil Embolization of Anterior Circulation Aneurysms. AJNR Am J Neuroradiol. 2019. PMID: 30975655. doi:10.3174/ajnr.A6035
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。