MRI诊断肱二头肌长头腱近端撕裂与不稳的准确性:100例肩关节与关节镜对照研究
回顾性分析100例因肩袖损伤行关节镜术前接受非增强1.5-T MRI的连续肩关节,由两名肌骨放射科医师独立评估肱二头肌长头腱撕裂与位置异常。MRI检出撕裂的敏感度71%–73%、特异度73%,全层撕裂特异度75%–96%,总体位移敏感度51%–58%、特异度70%–86%;观察者间Kappa 0.59–0.69,观察者内Kappa 0.74–0.82。作者结论为MRI诊断肱二头肌长头腱撕裂与不稳具有中等准确性和良好一致性。
要点
- MRI检出肱二头肌长头腱撕裂敏感度71%–73%、特异度73%,准确度中等。
- 全层撕裂特异度较高(75%–96%),合并肩袖前上撕裂时位移特异度升至73%–91%。
- 观察者间Kappa 0.59–0.69、观察者内Kappa 0.74–0.82,一致性良好。
核心结论
- MRI诊断肱二头肌长头腱撕裂与不稳具有中等准确性和良好一致性,全层撕裂及合并肩袖前上撕裂时的不稳似乎特异度更高。
研究设计与样本
- 回顾性分析前瞻性收集的100例连续肩关节数据,均为因肩袖损伤行关节镜术前接受非增强1.5-T MRI检查,由两名肌骨放射科医师独立分析,以关节镜手术为参考标准。
关键影像表现/征象
- 评估肱二头肌长头腱撕裂(完整、纵行劈裂、部分层厚、全层)与位置(正常、半脱位、脱位)。
- 同时评估肩袖前上撕裂,并以ramp试验评估肱二头肌长头腱稳定性。
诊断标准与关键数值
- 检出总体撕裂:敏感度71%–73%,特异度73%。
- 全层撕裂:特异度75%–96%。
- 总体位移:敏感度51%–58%,特异度70%–86%。
- 总体位移合并肩袖前上撕裂:特异度73%–91%。
- 观察者间Kappa 0.59–0.69,观察者内Kappa 0.74–0.82。
临床应用与阅片要点
- MRI可用于评估肱二头肌长头腱撕裂与不稳,诊断准确性中等,阅片时应结合肩袖前上撕裂情况综合判断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the diagnostic accuracy of magnetic resonance imaging (MRI) for detection of instability and tears of the proximal long head of biceps tendon (LHBT). To assess intraobserver and interobserver agreement.
MATERIALS AND METHODS: We performed a retrospective analysis of prospectively collected data of 100 consecutive shoulders who underwent non-contrast 1.5-T MRI prior to arthroscopic surgery due to rotator cuff injury. Images were independently analyzed by two musculoskeletal radiologists. LHBT was evaluated for presence of tearing (intact, longitudinal split, partial-thickness, or full-thickness) and position (normal, subluxated, and dislocated). Anterosuperior rotator cuff tears were also assessed. The reference standard was arthroscopic surgery. The ramp test was performed in order to evaluate LHBT stability. Diagnostic performance measures were determined and Kappa coefficients assessed agreement.
RESULTS: Concerning the detection of overall tears, sensitivity ranged from 71 to 73% and specificity was 73%. The specificity for full-thickness tears ranged from 75 to 96%. Overall displacement showed sensitivity ranging from 51 to 58% and specificity ranging from 70 to 86%. The specificity of overall displacement combined with anterosuperior rotator cuff tears ranged from 73 to 91%. Interobserver Kappa values were between 0.59 and 0.69. Intraobserver Kappa values were between 0.74 and 0.82.
CONCLUSIONS: MRI has moderate accuracy and good agreement for detection of LHBT tears and instability. There is a tendency for increased specificity for full-thickness tears and for instability in the coexistence of anterosuperior rotator cuff tears.
引用
- Baptista E, Malavolta EA, Gracitelli MEC, et al. Diagnostic accuracy of MRI for detection of tears and instability of proximal long head of biceps tendon: an evaluation of 100 shoulders compared with arthroscopy. Skeletal Radiol. 2019. PMID: 30937471. doi:10.1007/s00256-019-03214-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。