奥地利常规X线摄影与透视的诊断参考水平:基于全国调查的结果及更新后的国家诊断参考水平
该研究通过全国性调查评估并更新奥地利国家诊断参考水平(NDRLs),要求医院和放射中心报告常规X线摄影与透视检查的剂量面积乘积(DAP)数据。调查显示,常规X线摄影的DAP例数为1005至2121例,透视为182至1380例;患者平均体重分别为75 kg和77 kg。调查得出的第3四分位数显著低于2018年初前有效的旧版奥地利NDRLs,且与欧洲NDRLs吻合良好。
要点
- 更新后的第3四分位数显著低于旧版奥地利NDRLs(2018年初前有效)。
- 调查覆盖常规X线摄影(头颅、胸部、腹部、骨盆、腰椎、床旁胸片)和透视(钡灌肠单/双对比、吞咽视频)。
- 59%受邀机构提交DAP数据,43%提交患者体重,41%提交透视时间。
核心结论
- 调查得出的第3四分位数显著低于旧版奥地利NDRLs(2018年初前有效),且与欧洲NDRLs吻合良好,更新符合欧洲DRL统一协调工作。
研究设计与样本
- 全国性调查,邀请所有相关奥地利医院和放射科办公室/中心报告至少10例代表性DAP值及患者体重和透视时间(如适用),共59%受邀机构提交DAP数据。
诊断标准与关键数值
- 常规X线摄影DAP例数1005至2121例,透视182至1380例;常规X线摄影平均患者体重75 kg,透视77 kg;计算设施中位数和平均DAP的第3四分位数并与奥地利及国际NDRLs比较。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Evaluation and updating of Austrian National Diagnostic Reference Levels (NDRLs).
METHODS: A nationwide survey on common conventional radiography and fluoroscopy examinations was conducted. In line with Austrian radiation protection standards, all relevant Austrian hospitals and radiology offices/centers were asked to report a minimum sample of 10 representative dose-area product (DAP) values together with patient weight and fluoroscopy time, if applicable. Examinations included for conventional radiography were skull, chest, abdomen, pelvis, lumbar spine and bedside chest x-ray, for fluoroscopy barium enema (single and double contrast) and swallowing (video). Participants were invited via e-mail, followed up by reminders to increase participation rates. Plausibility checks were performed to increase data quality. 3rd quartiles of facility median and mean DAP were calculated and compared to Austrian and international NDRLs.
RESULTS: 59% of invited facilities submitted DAP data, 43% submitted additional data on patient weight and 41% on fluoroscopy time. DAP case numbers varied from 1005 to 2121 for conventional radiography and from 182 to 1380 for fluoroscopy. Average patient weight was 75 kg for conventional radiography and 77 kg for fluoroscopy.
CONCLUSION: 3rd quartiles derived from the survey are substantially lower than the old Austrian NDRLs (valid till early 2018). Since 3rd quartiles correspond well to European NDRLs, the update would be in accordance with European DRL harmonisation efforts.
引用
- Wachabauer D, Röthlin F, Moshammer HM, et al. Diagnostic Reference Levels for conventional radiography and fluoroscopy in Austria: Results and updated National Diagnostic Reference Levels derived from a nationwide survey. Eur J Radiol. 2019. PMID: 30927937. doi:10.1016/j.ejrad.2019.02.015