文献速递胸部心血管外周血管MRCTUS

使用具有血池特性对比剂的磁共振血管成像评估肺栓塞,作为避免辐射暴露的计算机断层扫描替代方案

Magnetic resonance angiography imaging of pulmonary embolism using agents with blood pool properties as an alternative to computed tomography to avoid radiation exposure.
PubMed 文献 · Eur J Radiol · 2019-02-11

前瞻性临床研究纳入40例急诊疑似肺栓塞并计划行CTPA的患者,采用单次注射血池特性对比剂钆磷维塞三钠或钆贝葡胺行胸部MRA及骨盆大腿MRV,与CTPA和彩色多普勒超声对照。MRA诊断肺栓塞的敏感度100%、特异度97%,MRV诊断深静脉血栓的敏感度和特异度均为100%。作者认为该联合方案有潜力作为CTPA的替代影像选择,但需进一步大规模多中心研究。

要点

  • 疑似肺栓塞患者行单次注射血池对比剂MRA-MRV联合检查,MRA诊断肺栓塞敏感度100%、特异度97%。
  • MRV评估深静脉血栓的敏感度和特异度均为100%,但仅小部分患者接受了临床DUS对照。
  • 该单中心初步研究提示联合MRA-MRV有潜力替代CTPA,原文指出需进一步大规模多中心研究。

核心结论

  • 使用血池特性对比剂行相对快速联合MRA-MRV检查评估肺栓塞和膝以上深静脉血栓,单中心初步研究显示有潜力作为CTPA的替代影像选择,原文指出需进一步大规模多中心研究。

研究设计与样本

  • 前瞻性临床研究,纳入40例急诊疑似肺栓塞并计划行临床指征CTPA的患者,采用单次对比剂注射行胸部MRA和骨盆及大腿MRV,对比剂为钆磷维塞三钠和钆贝葡胺,参考标准分别为CTPA和彩色多普勒超声。

诊断标准与关键数值

  • MRA对比CTPA诊断肺栓塞,按患者计算敏感度100%、特异度97%;MRV对比临床DUS诊断深静脉血栓,敏感度和特异度均为100%,仅小部分患者接受了临床DUS评估。

临床应用与阅片要点

  • 原文结论认为该联合MRA-MRV方案有潜力作为CTPA的替代影像选择,原文指出需进一步大规模多中心研究。

局限性

  • 原文写明本研究为单中心初步研究。
  • 原文指出需进一步大规模多中心研究。
  • 仅小部分患者接受了临床DUS评估深静脉血栓。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the feasibility and accuracy of a combined magnetic resonance angiography (MRA) - magnetic resonance venography (MRV) protocol using contrast agents with blood pool properties, gadofosveset trisodium and gadobenate dimeglumine, in the evaluation of pulmonary embolus (PE) and deep venous thrombosis (DVT) as compared to the standard clinical reference imaging modalities; computed tomography pulmonary angiography (CTPA) and color-coded Duplex ultrasound (DUS).

MATERIALS AND METHODS: This prospective clinical study recruited patients presenting to the emergency department with clinical suspicion for PE and scheduled for a clinically indicated CTPA. We performed both MRA of the chest for the evaluation of PE as well as MRV of the pelvis and thighs to evaluate for DVT using a single contrast injection. MRA-MRV data was compared to the clinical reference standard CTPA and DUS, respectively.

RESULTS: A total of 40 patients were recruited. The results on a per-patient basis comparing MRA to CTPA for pulmonary embolus yielded 100% sensitivity and 97% specificity. There was a small subset of patients that underwent clinical DUS to evaluate for DVT, which demonstrated a sensitivity and specificity of 100% for MRV.

CONCLUSIONS: This single-center, preliminary study using contrast agents with blood pool properties to perform a relatively rapid combined MRA-MRV exam to image for PE and above knee DVT shows potential as an alternative imaging choice to CTPA. Further large-scale, multicentre studies are warranted.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Pressacco J, Papas K, Lambert J, et al. Magnetic resonance angiography imaging of pulmonary embolism using agents with blood pool properties as an alternative to computed tomography to avoid radiation exposure. Eur J Radiol. 2019. PMID: 30927943. doi:10.1016/j.ejrad.2019.02.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。