双能CT-DSA评估骨性脊柱转移瘤血供:与导管血管造影对照的初步研究
回顾性纳入15例脊柱转移瘤患者,行双能CT、常规DSA及后续减瘤手术;CT-DSA与常规DSA血供评估强相关(ρ=0.87,P<.001),定量强化指数与DSA强相关(ρ=0.83,P<.001);富血供与非富血供组强化指数差异有统计学意义(P=.0003),两组术中出血量差异无统计学意义(P=.09);作者认为CT-DSA可作为术前无创评估选项。
要点
- CT-DSA与常规DSA评估脊柱转移瘤血供强相关(ρ=0.87,P<.001)。
- 定量强化指数与DSA强相关(ρ=0.83,P<.001)。
- 富血供与非富血供组强化指数差异有统计学意义(P=.0003)。
核心结论
- 双能CT-DSA与常规DSA在评估脊柱转移瘤血供方面强相关,可能作为减瘤术前无创评估选项。
研究设计与样本
- 回顾性研究,2018年1月至12月,共15例脊柱转移瘤患者,均行双能CT、常规DSA及后续减瘤手术;CT-DSA图像经刚性配准及CT期相间减影生成;以常规DSA为参照,采用Spearman系数评估相关性,采用Wilcoxon秩和检验比较富血供与非富血供组。
关键影像表现/征象
- CT-DSA与常规DSA血供评估结果强相关,ρ=0.87(P<.001)。
- 定量强化指数与DSA强相关,ρ=0.83(P<.001)。
- 富血供与非富血供CT-DSA组强化指数差异有统计学意义(P=.0003)。
- 富血供与非富血供组术中出血量差异无统计学意义(P=.09)。
诊断标准与关键数值
- CT-DSA与常规DSA血供评估的Spearman相关系数ρ=0.87(P<.001)。
- 定量强化指数与DSA的Spearman相关系数ρ=0.83(P<.001)。
- 富血供与非富血供CT-DSA组强化指数比较P=.0003。
临床应用与阅片要点
- 作者认为双能CT-DSA可能作为减瘤术前无创评估血供的选项。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Spine debulking surgery in patients with hypervascular spinal metastasis is associated with massive intraoperative blood loss, but currently, the vascularity of tumor is determined by invasive conventional angiography or dynamic contrast MR imaging. We aimed to investigate the usefulness of noninvasive dual-energy CT-DSA, comparing it with conventional angiography in evaluating the vascularity of spinal metastasis.
MATERIALS AND METHODS: We conducted a retrospective study from January to December 2018. A total of 15 patients with spinal metastasis undergoing dual-energy CT, conventional DSA, and subsequent debulking surgery were included. CT-DSA images were produced after rigid-body registration and subtraction between CT phases. Qualitative and quantitative assessments of tumor vascularity were conducted. Correlations between CT-DSA and conventional DSA results were evaluated using the Spearman coefficient. The mean enhancement in the estimated tumor volume and surgical blood loss was compared between hypervascular and nonhypervascular groups using the Wilcoxon rank sum test.
RESULTS: The CT-DSA and DSA results were strongly correlated, with ρ = 0.87 (P < .001). The DSA and the quantitative enhancement index also showed a strong correlation with ρ = 0.83 (P < .001). Wilcoxon rank sum testing between hypervascular and nonhypervascular CT-DSA groups showed a difference in enhancement indices (P = .0003). The blood loss between the hypervascular and nonhypervascular groups was nonsignificant (P = .09).
CONCLUSIONS: Dual-energy CT-DSA correlates well with conventional DSA in assessing the vascularity of spinal metastasis. It may serve as a noninvasive preoperative evaluation option before debulking surgery.
引用
- Huang YC, Tsuang FY, Lee CW, et al. Assessing Vascularity of Osseous Spinal Metastases with Dual-Energy CT-DSA: A Pilot Study Compared with Catheter Angiography. AJNR Am J Neuroradiol. 2019. PMID: 30948377. doi:10.3174/ajnr.A6023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。