弥散加权成像-分数ADC分析评估巨细胞瘤
研究纳入腱鞘与骨巨细胞瘤,由两位骨肌放射科医师在常规MRI与DWI上测量ADC,并用MATLAB计算分数ADC与最佳拟合ADC。腱鞘与骨巨细胞瘤ADC值无统计学显著差异,全部病灶平均ADC为1.0×10-3 mm2/s(SD=0.2×10-3 mm2/s)、最小ADC为0.5×10-3 mm2/s(SD=0.3×10-3 mm2/s);B50-B400斜率所得平均ADC为1.1×10-3 mm2/s(SD=0.2×10-3 mm2/s),B400-B800斜率所得平均ADC为0.8×10-3 mm2/s(SD=0.1×10-3 mm2/s),P<0.01。
要点
- 腱鞘与骨巨细胞瘤ADC值相似且偏低,二者间无统计学显著差异。
- 全部病灶平均ADC为1.0×10-3 mm2/s,最小ADC为0.5×10-3 mm2/s。
- 高b值配对(B400-B800)所得ADC低于低b值配对(B50-B400),P<0.01。
核心结论
- 腱鞘与骨巨细胞瘤ADC值相似且偏低,使用高b值配对时ADC值更低;研究结果支持巨细胞瘤在低b值下可见与高灌注相关的体素内不相干运动效应。
研究设计与样本
- 纳入腱鞘与骨巨细胞瘤病灶,由两位骨肌放射科医师在常规MRI与DWI上评估,于病灶强化最融合区域放置ROI测量ADC,并用MATLAB软件计算分数ADC与最佳拟合ADC。
诊断标准与关键数值
- 全部病灶平均ADC为1.0×10-3 mm2/s(SD=0.2×10-3 mm2/s),最小ADC为0.5×10-3 mm2/s(SD=0.3×10-3 mm2/s)。
- B50-B400斜率所得平均ADC为1.1×10-3 mm2/s(SD=0.2×10-3 mm2/s),B400-B800斜率所得平均ADC为0.8×10-3 mm2/s(SD=0.1×10-3 mm2/s),P<0.01。
- 腱鞘与骨巨细胞瘤的ADC值之间无统计学显著差异。
临床应用与阅片要点
- ADC测量应将ROI置于病灶强化最融合区域。
- 判读巨细胞瘤ADC时需注意所用b值配对,高b值配对所得ADC更低。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: A single ADC value is used in clinical practice on multi b-value acquisitions. Low b-value acquisitions are affected by intravoxel incoherent motion, which is dependent on perfusion. Giant cell tumors (GCTs) are known to exhibit early arterial enhancement and low ADC values. Mean, minimum and fractional ADC characteristics of osseous and tenosynovial GCTs are systematically evaluated.
METHODS: Tenosynovial and osseous GCTs were included. Each lesion was evaluated on conventional MRI and DWI by two musculoskeletal radiologists. ADC was measured by placing an ROI on the most confluent enhancing portion of the lesion. Fractional and best fit ADC calculations were performed using MATLAB software.
RESULTS: No statistically significant difference was found between tenosynovial and osseous lesions' ADC values. Mean ADC for all lesions was 1.0 × 10-3 mm2/s (SD = 0.2 × 10-3 mm2/s) and minimum ADC was 0.5 × 10-3 mm2/s (SD = 0.3 × 10-3 mm2/s). Average mean ADC value obtained from B50-B400 slope was 1.1 × 10-3 mm2/s (SD = 0.2 × 10-3 mm2/s), and the average mean ADC value obtained from B400-B800 slope was 0.8 × 10-3 mm2/s (SD = 0.1 × 10-3 mm2/s) [p-value <0.01].
CONCLUSION: Tenosynovial and osseous GCTs demonstrate similar and low ADC values, which become even lower when using high b-value pairs. Our study also supports the theory of intravoxel incoherent motion that becomes apparent at low b values as related to giant cell tumors, which are known to be hyperperfused.
引用
- Ashikyan O, Chalian M, Moore D, et al. Evaluation of giant cell tumors by diffusion weighted imaging-fractional ADC analysis. Skeletal Radiol. 2019. PMID: 31001688. doi:10.1007/s00256-019-03219-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。