超声参数对腕管综合征的诊断准确性:额外的诊断标准
研究在马尼拉大都会招募有或无腕管综合征症状的成年志愿者,以体格检查和神经传导研究为参考标准,盲法测量腕管入口和出口处正中神经超声参数。腕管出口腕前臂差大于0.03 cm与腕管综合征关联最强(比值比4.7,95%CI 1.4-15.9),曲线下面积0.58,敏感度94.4%,特异度21.7%;联合出口充血1+后曲线下面积升至0.59(敏感度98.1%,特异度27.7%)。作者认为联合出口腕前臂差和充血可提供敏感的替代诊断工具。
要点
- 腕管出口腕前臂差>0.03 cm与腕管综合征关联最强,比值比4.7。
- 出口腕前臂差诊断曲线下面积0.58,敏感度94.4%,特异度21.7%。
- 联合出口充血1+后曲线下面积0.59,敏感度98.1%,特异度27.7%。
核心结论
- 联合腕管出口腕前臂差和充血可提供敏感的腕管综合征替代诊断工具。
研究设计与样本
- 在马尼拉大都会办公室招募有或无腕管综合征症状的成年志愿者,共117名参与者(234只手),其中54只手(23.1%)诊断为腕管综合征;以体格检查阳性发现和神经传导研究为独立参考标准;盲法测量腕管入口和出口处正中神经超声参数。
诊断标准与关键数值
- 腕管出口腕前臂差>0.03 cm诊断腕管综合征的比值比4.7(95%CI 1.4-15.9),曲线下面积0.58,敏感度94.4%,特异度21.7%。
临床应用与阅片要点
- 作者认为联合腕管出口腕前臂差和充血可提供敏感的替代诊断工具;诊断能力独立于年龄和症状持续时间。
局限性
- 腕管出口腕前臂差>0.03 cm的比值比95%CI为1.4-15.9。
- 腕管出口腕前臂差>0.03 cm的曲线下面积为0.58。
- 联合出口充血1+后曲线下面积仅升至0.59。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To determine the diagnostic capacity of ultrasound (US) in detecting carpal tunnel syndrome (CTS).
METHODS: Volunteer adults with and without CTS symptoms were recruited from offices in metropolitan Manila, where employees' work was hand/wrist intensive. Carpal tunnel syndrome was independently diagnosed by a reference standard (positive findings on a physical examination and nerve conduction studies). Blinded US measurements were taken of the median nerve (cross-sectional area, hypervascularity, wrist-to-forearm ratio, wrist-forearm difference, swelling ratio, flattening ratio, and palmar bowing of the flexor retinaculum) at the carpal tunnel inlet and carpal tunnel outlet (CTO).
RESULTS: A total of 117 eligible consenting participants (234 hands) were included, with 54 hands (23.1%) with a diagnosis of CTS. There were no anthropometric differences between arms with and without CTS. Men and women older than 33 years were 5 times more likely to report CTS than younger people. A CTO wrist-forearm difference of greater than 0.03 cm had the strongest association with CTS (odds ratio, 4.7; 95% confidence interval, 1.4-15.9), with an area under the curve of 0.58 (sensitivity, 94.4%; specificity, 21.7%). The area under the curve increased to 0.59 when the next strongest measurement (CTO hypervascularity of 1+: odds ratio, 3.8; 95% confidence interval, 1.8-8.1) was included (sensitivity, 98.1%; specificity, 27.7%). Adding further US parameters did not improve the diagnostic capacity of US for CTS. Diagnostic capacity was independent of age and the duration of CTS symptoms.
CONCLUSIONS: Combining US findings for the CTO wrist-forearm difference and hypervascularity provides a sensitive, alternative diagnostic tool for CTS.
引用
- Gonzalez-Suarez CB, Fidel BC, Cabrera JTC, et al. Diagnostic Accuracy of Ultrasound Parameters in Carpal Tunnel Syndrome: Additional Criteria for Diagnosis. J Ultrasound Med. 2019. PMID: 30993769. doi:10.1002/jum.15012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。