文献速递甲状腺与浅表头颈US

计算机辅助影像分析系统对甲状腺结节超声风险分层的诊断性能评估

Diagnostic Performance Evaluation of a Computer-Assisted Imaging Analysis System for Ultrasound Risk Stratification of Thyroid Nodules.
PubMed 文献 · AJR Am J Roentgenol · 2019-04-11

该研究回顾性分析300个甲状腺结节(135个恶性)术前超声图像,由甲状腺专家与计算机辅助诊断(CADx)程序AmCAD-UT分别按ATA、EU-TIRADS及AACE/ACE/AME标准进行风险分层。使用ATA标准时专家敏感度87.0%、特异度91.2%、阳性预测值90.5%、阴性预测值90.9%,CADx敏感度相似但特异度和阳性预测值较低,ROC AUC专家为0.88、CADx为0.72。结论认为该CADx程序可用于甲状腺结节风险分层,但性能未优于超声专家。

要点

  • ATA标准下专家敏感度87.0%、特异度91.2%、阳性预测值90.5%、阴性预测值90.9%。
  • CADx使用三种分类系统时敏感度与专家相似,但特异度和阳性预测值较低。
  • ATA标准下阴性预测值专家90.9% vs CADx 86.3%(p=0.07),无显著差异。

核心结论

  • 该CADx超声图像分析程序有助于甲状腺结节风险分层,但性能未优于超声专家。

研究设计与样本

  • 回顾性研究,纳入300个甲状腺结节(135个恶性)术前超声图像,由甲状腺专家与CADx程序(AmCAD-UT,AmCAD Biomed)分别按ATA、EU-TIRADS及AACE/ACE/AME分类系统进行风险分层并比较。

诊断标准与关键数值

  • ATA标准下专家敏感度87.0%、特异度91.2%、阳性预测值90.5%、阴性预测值90.9%;CADx使用ATA标准时阴性预测值86.3%(与专家90.9%比较p=0.07);ATA标准下ROC AUC专家0.88、CADx 0.72。

临床应用与阅片要点

  • 甲状腺专家按ATA标准判读可获得敏感度87.0%、特异度91.2%的风险分层性能。
  • CADx程序可用于甲状腺结节风险分层,但敏感度与专家相似而特异度和阳性预测值较低。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. Ultrasound-based stratification of the malignancy risk of thyroid nodules has potential variability. The purpose of this study is to evaluate the diagnostic effectiveness of the first commercially available system for computer-aided diagnosis (CADx) imaging analysis. MATERIALS AND METHODS. Ultrasound images of 300 thyroid nodules (135 of which were malignant) acquired before surgical treatment were retrospectively reviewed by a thyroid expert, and his classification of each image was then compared with the classification rendered by an image analysis program (AmCAD-UT, AmCAD Biomed). The American Thyroid Association (ATA) classification system, the European Thyroid Imaging Reporting and Data System (EU-TIRADS), and the classification system jointly proposed by American and Italian associations of clinical endocrinologists (the American Association of Clinical Endocrinologists [AACE], the American College of Endocrinology [ACE], and Associazione Medici Endocrinologi [AME]) were used for risk stratification. RESULTS. The diagnostic performance of the thyroid expert when the ATA system was used was as follows: sensitivity, 87.0%; specificity, 91.2%; positive predictive value, 90.5%; and negative predictive value, 90.9%. Compared with the expert, the CADx program, when used with the three classification systems, had a similar sensitivity but a lower specificity and positive predictive value. Regarding the negative predictive value, the results of the expert did not differ from those of the CADx program when it applied the ATA classification system (90.9% vs 86.3%; p = 0.07). The ROC AUC value was 0.88 for the expert clinician and 0.72 for the CADx program when the ATA classification system was used. CONCLUSION. The CADx ultrasound image analysis program described in the present study is useful for risk stratification of thyroid nodules, but it does not perform better than a sonography expert.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Reverter JL, Vázquez F, Puig-Domingo M, et al. Diagnostic Performance Evaluation of a Computer-Assisted Imaging Analysis System for Ultrasound Risk Stratification of Thyroid Nodules. AJR Am J Roentgenol. 2019. PMID: 30973776. doi:10.2214/AJR.18.20740

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。