文献速递甲状腺与浅表头颈US

线性与非线性机器学习算法在甲状腺结节分类中的比较

Comparison between linear and nonlinear machine-learning algorithms for the classification of thyroid nodules.
PubMed 文献 · Eur J Radiol · 2019-02-27

本研究以病理报告或细针穿刺活检为参考标准,回顾性分析1179个甲状腺结节的超声特征,比较5种非线性与3种线性机器学习算法的分类性能。结果显示非线性算法与线性算法的AUC相似,随机森林与核支持向量机在验证队列中AUC略高(均为0.954,95%CI:0.939-0.969)。

要点

  • 非线性与线性机器学习算法在甲状腺结节良恶性分类中AUC相似。
  • 随机森林与核支持向量机在验证队列中AUC略高于其他算法,均为0.954。
  • 研究采用病理或FNA活检为参考标准,评估11项超声特征。

核心结论

  • 总体上,非线性机器学习算法与线性算法在评估甲状腺结节恶性风险方面性能相似。

研究设计与样本

  • 回顾性分析,共1179个甲状腺结节(训练队列n=700,验证队列n=479),以病理报告或细针穿刺活检为参考标准,评估11项超声特征,比较5种非线性与3种线性机器学习算法。

关键影像表现/征象

  • 评估的超声特征包括大小(最大径)、边缘、形态、纵横比、包膜、低回声晕、组成、回声、钙化模式、血供及颈部淋巴结状态。

诊断标准与关键数值

  • 随机森林算法在验证队列的AUC为0.954(95%CI:0.939-0.969)。
  • 核支持向量机算法在验证队列的AUC为0.954(95%CI:0.939-0.969)。
  • 各算法诊断性能通过受试者工作特征曲线下面积(AUC)比较,重复1000次获得平均AUC及95%CI。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: A key challenge in thyroid carcinoma is preoperatively diagnosing malignant thyroid nodules. The purpose of this study was to compare the classification performance of linear and nonlinear machine-learning algorithms for the evaluation of thyroid nodules using pathological reports as reference standard.

METHODS: Ethical approval was obtained for this retrospective analysis, and the informed consent requirement was waived. A total of 1179 thyroid nodules (training cohort, n = 700; validation cohort, n = 479) were confirmed by pathological reports or fine-needle aspiration (FNA) biopsy. The following ultrasonography (US) featu res were measured for each nodule: size (maximum diameter), margins, shape, aspect ratio, capsule, hypoechoic halo, composition, echogenicity, calcification pattern, vascularity, and cervical lymph node status. We analyzed five nonlinear and three linear machine-learning algorithms. The diagnostic performance of each algorithm was compared by using the area under the curve (AUC) of the receiver operating characteristic curve. We repeated this process 1000 times to obtain the mean AUC and 95% confidence interval (CI).

RESULTS: Overall, nonlinear machine-learning algorithms demonstrated similar AUCs compared with linear algorithms. The Random Forest and Kernel Support Vector Machines algorithms achieved slightly greater AUCs in the validation cohort (0.954, 95% CI: 0.939-0.969; 0.954 95%CI: 0.939-0.969, respectively) than other algorithms.

CONCLUSIONS: Overall, nonlinear machine-learning algorithms share similar performance compared with linear algorithms for the evaluation the malignancy risk of thyroid nodules.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ouyang FS, Guo BL, Ouyang LZ, et al. Comparison between linear and nonlinear machine-learning algorithms for the classification of thyroid nodules. Eur J Radiol. 2019. PMID: 30927956. doi:10.1016/j.ejrad.2019.02.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。