文献速递乳腺MR

全肿瘤表观扩散系数直方图分析是否有助于评估乳腺叶状肿瘤分级

Can whole-tumor apparent diffusion coefficient histogram analysis be helpful to evaluate breast phyllode tumor grades?
PubMed 文献 · Eur J Radiol · 2019-02-27

该回顾性研究纳入2011年8月至2017年11月56例乳腺叶状肿瘤(23例良性、22例交界性、11例恶性),采用1.5 T MRI比较常规MRI特征与三种ROI(圆形、单层、全肿瘤)ADC直方图参数对良性与交界性/恶性叶状肿瘤的鉴别价值。结果显示仅边缘、囊性成分、T2WI瘤周水肿和囊壁在两组间有显著差异,而各ADC参数在两组间均无显著差异,全肿瘤ADC直方图未能改善分级鉴别。

要点

  • 常规MRI特征中边缘(P=0.011)、囊性成分(P<0.001)、T2WI瘤周水肿(P<0.001)和囊壁(P=0.011)在良性与交界性/恶性叶状肿瘤间有显著差异。
  • 全肿瘤ADC直方图均值及第10、25、50、75百分位数在良性与交界性/恶性组间均无显著差异。
  • 全肿瘤ADC直方图均值及第10、25、50、75百分位数的ROC曲线下面积分别为0.568、0.613、0.567、0.544和0.540。

核心结论

  • 基于本研究结果,全肿瘤ADC直方图不能改善乳腺叶状肿瘤分级的鉴别,而常规MRI可提供更有意义的信息,形态学特征可能比ADC值更有价值,ADC可作为鉴别叶状肿瘤分级的补充方法。

研究设计与样本

  • 经机构审查委员会批准的回顾性研究,纳入2011年8月至2017年11月56例乳腺叶状肿瘤(23例良性、22例交界性、11例恶性),使用1.5 T MR系统配4通道SENSE乳腺线圈行MRI检查,以病理分级为参考标准。

关键影像表现/征象

  • 边缘、囊性成分、T2WI瘤周水肿和囊壁在良性叶状肿瘤与交界性/恶性叶状肿瘤组间差异有统计学意义(P=0.011、P<0.001、P<0.001、P=0.011)。
  • ADC参数显示单层ROI测值倾向于高于圆形ROI和全肿瘤ROI,而圆形ROI与全肿瘤ROI测值相近。

诊断标准与关键数值

  • 良性叶状肿瘤与交界性/恶性叶状肿瘤组间比较,圆形ROI、单层ROI及全肿瘤ROI均值以及全肿瘤ROI第10、25、50、75百分位数的ADC值均无显著差异。
  • 全肿瘤ROI均值及第10、25、50、75百分位数的ROC曲线下面积分别为0.568、0.613、0.567、0.544和0.540。
  • 观察者内一致性:圆形ROI、单层ROI和全肿瘤ROI的组内相关系数分别为0.905、0.965和0.994(P>0.05)。
  • Ki-67以14%为界分组,Ki-67<14%为阴性组,Ki-67≥14%为阳性组;交界性/恶性组中仅23例有Ki-67结果,其中17例为阳性。

临床应用与阅片要点

  • 作者认为常规MRI形态学特征(边缘、囊性成分、T2WI瘤周水肿、囊壁)可能比ADC值更有价值,ADC可作为鉴别叶状肿瘤分级的补充方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate whether whole-tumor apparent diffusion coefficient (ADC) histogram analysis could be helpful to evaluate breast phyllode tumor (PT) grades.

MATERIALS AND METHODS: This institutional review board-approved retrospective study included 56 PTs (23 benign lesions, 22 borderline lesions, and 11 malignant lesions) from August 2011 to November 2017. MRI was performed using a 1.5 T MR system equipped with a 4-channel SENSE breast coil. All cases were divided into two groups, benign PT (BPT) and borderline or malignant PT (BMPT). The conventional MR parameters included age, longest diameter, shape, margin, internal enhancement characteristics, cystic component of the tumor, wall of the cystic component, peritumoral edema on T2-weighted imaging (T2WI), T1-weighted imaging (T1WI) and T2WI signal intensity, time-signal intensity curve (TIC) patterns and early-stage enhancement ratio (EER). The ADC values were determined in three different types of regions of interest (ROIs), including a circular ROI (ROI-c), single-slice ROI (ROI-s), and whole-tumor ROI (ROI-w). All ADC values were measured twice by Observer A and B (with a 2-week interval). The Ki-67 index was determined, and cases were classified into a "negative group" (Ki-67<14%) and a "positive group" (Ki-67≥14%). SPSS Statistics V21.0 was used for the statistical analyses.

RESULTS: Our study included 23 cases of BPT and 33 cases of BMPT (including 22 borderline PTs and 11 malignant PTs). Only 23 patients in BMPT group had Ki-67 results, and 17 of these were positive. Regarding conventional MR features, significant differences were observed in the margin (P = 0.011), cystic component (P<0.001), peritumoral edema on T2WI (P<0.001), and cystic wall (P = 0.011) of the PT between the BPT and BMPT groups. Regarding the ADC value, good intraobserver agreement for ROI-c, ROI-s and ROI-w measurements was obtained. For the three different ROIs, the intraclass correlation coefficient (ICC) values were 0.905 for ROI-c (P > 0.05), 0.965 (P > 0.05) for ROI-s and 0.994 (P > 0.05) for ROI-w. ADC parameter indicated that the figure of ROI-s tended to be higher than the ROI-c and ROI-w, while the ROI-c and ROI-w values were similar. However, no significant difference was found in ADC values between the BPT and BMPT groups for ROI-c, ROI-s and mean ROI-w values and the 10th, 25th, 50th and 75th ROI-w. The areas under the ROC curves for the mean ROI-w and the 10th, 25th, 50th and 75th ROI-w were 0.568, 0.613, 0.567, 0.544, and 0.540, respectively.

CONCLUSION: Based on the results obtained in our study, the whole-tumor ADC histogram could not improve differentiation of the breast PT grade, while conventional MR images could provide more meaningful information, so morphological characteristics may be valuable than ADC value, and ADC could be used as a supplemental method to differentiate PT grades.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Guo Y, Tang WJ, Kong QC, et al. Can whole-tumor apparent diffusion coefficient histogram analysis be helpful to evaluate breast phyllode tumor grades? Eur J Radiol. 2019. PMID: 31005172. doi:10.1016/j.ejrad.2019.02.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。