宽角数字乳腺断层摄影能否替代全视野数字乳腺摄影?一项多阅片者多病例研究
多阅片者多病例研究纳入330例患者病例,比较双视角宽角数字乳腺断层摄影(DBT)与全视野数字乳腺摄影(FFDM)独立阅片对乳腺癌的检出效能。患者水平AUC从FFDM的0.765升至DBT的0.835(p=0.002),乳腺水平AUC从0.818升至0.861(p=0.011),DBT非癌症召回率降低19%(p<0.001)。结论认为宽角双视角DBT作为单独视角具有稳健性,但视觉科学感知研究支持纳入概览图像。
要点
- 患者水平AUC:FFDM 0.765 vs DBT 0.835,DBT较高(p=0.002)。
- 乳腺水平AUC:FFDM 0.818 vs DBT 0.861,DBT较高(p=0.011)。
- DBT非癌症召回率较FFDM降低19%(p<0.001),肿块和结构扭曲检出更多(p<0.001)。
核心结论
- 宽角双视角DBT作为单独视角可提高乳腺癌检出阅片者效能,结果验证其稳健性;但视觉科学感知研究支持纳入概览图像。
研究设计与样本
- 多阅片者多病例研究,从764例接受筛查和诊断性乳腺摄影的患者中选取330例患者病例,31名阅片者独立阅读双侧双视角FFDM与双侧双视角宽角DBT图像,两次阅片间隔超过1个月。
关键影像表现/征象
- DBT对肿块和结构扭曲的检出多于FFDM(p<0.001)。
- DBT对钙化的检出呈降低趋势(p=0.136)。
- DBT对浸润性癌的检出准确度显著高于FFDM(p<0.001)。
诊断标准与关键数值
- 患者水平AUC:FFDM 0.765(SE 0.027)vs DBT 0.835(SE 0.027),p=0.002。
- 乳腺水平AUC:FFDM 0.818(SE 0.019)vs DBT 0.861(SE 0.019),p=0.011。
- 每患者非癌症召回率:DBT较FFDM降低19%(p<0.001)。
临床应用与阅片要点
- 31名阅片者中29名使用DBT的阅片效能优于FFDM,与乳腺密度无关。
- 作者结论认为宽角双视角DBT作为单独视角具有稳健性,但视觉科学感知研究支持纳入概览图像。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study was to test the hypothesis whether two-view wide-angle digital breast tomosynthesis (DBT) can replace full-field digital mammography (FFDM) for breast cancer detection. SUBJECTS AND METHODS. In a multireader multicase study, bilateral two-view FFDM and bilateral two-view wide-angle DBT images were independently viewed for breast cancer detection in two reading sessions separated by more than 1 month. From a pool of 764 patients undergoing screening and diagnostic mammography, 330 patient-cases were selected. The endpoints were the mean ROC AUC for the reader per breast (breast level), ROC AUC per patient (subject level), noncancer recall rates, sensitivity, and specificity. RESULTS. Twenty-nine of 31 readers performed better with DBT than FFDM regardless of breast density. There was a statistically significant improvement in readers' mean diagnostic accuracy with DBT. The subject-level AUC increased from 0.765 (standard error [SE], 0.027) for FFDM to 0.835 (SE, 0.027) for DBT (p = 0.002). Breast-level AUC increased from 0.818 (SE, 0.019) for FFDM to 0.861 (SE, 0.019) for DBT (p = 0.011). The noncancer recall rate per patient was reduced by 19% with DBT (p < 0.001). Masses and architectural distortions were detected more with DBT (p < 0.001); calcifications trended lower (p = 0.136). Accuracy for detection of invasive cancers was significantly greater with DBT (p < 0.001). CONCLUSION. Reader performance in breast cancer detection is significantly higher with wide-angle two-view DBT independent of FFDM, verifying the robustness of DBT as a sole view. However, results of perception studies in the vision sciences support the inclusion of an overview image.
引用
- Georgian-Smith D, Obuchowski NA, Lo JY, et al. Can Digital Breast Tomosynthesis Replace Full-Field Digital Mammography? A Multireader, Multicase Study of Wide-Angle Tomosynthesis. AJR Am J Roentgenol. 2019. PMID: 30933648. doi:10.2214/AJR.18.20294
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。