文献速递乳腺乳腺X线MR

对比增强数字乳腺X线摄影与磁共振成像对乳腺癌肿瘤大小测量的准确性比较

Contrast enhanced digital mammography versus magnetic resonance imaging for accurate measurement of the size of breast cancer.
PubMed 文献 · Br J Radiol · 2019-04-24

纳入52例因乳腺癌手术的女性,比较乳腺X线摄影、对比增强数字乳腺X线摄影(CEDM)及磁共振成像(含MIP图)测量肿瘤最大径与病理的一致性。CEDM各视图和MRI与浸润性成分病理大小一致性良好(k>0.75),CEDM的CC视图和MRI轴位MIP图结果最优。作者认为CEDM可作为CEMRI的替代模态。

要点

  • CEDM各视图及MRI测量乳腺癌大小与病理浸润性成分一致性良好(k>0.75)。
  • CEDM的CC视图测量准确性最高,其次为MRI轴位MIP图。
  • 轴位CEDM和MRI可作为影像复核及治疗计划的首选。

核心结论

  • CEDM和MRI的所有视图均能准确测量肿瘤大小,轴位CEDM和MRI可作为影像复核和治疗计划的首选,其中CEDM的CC视图准确性最高。

研究设计与样本

  • 纳入52例(平均年龄50.9岁)因乳腺癌手术的女性,术前测量乳腺X线摄影及CEDM的MLO和CC视图、MRI矢状位和轴位MIP图像及早期动态增强MRI(CEMRI)上主病灶最大径,以病理(仅浸润性成分OPinvasive或含原位癌OPmax)为参考标准,采用Bland-Altman图、组内相关系数和单变量线性回归分析评估。

诊断标准与关键数值

  • 平均OPinvasive为15.5 mm,除乳腺X线摄影CC视图和CEDM轴位MIP图外,所有图像的高估率相似或高于低估率。
  • 平均OPmax为21.7 mm,低估率高于高估率。
  • CEDM和CEMRI所有参数与OPinvasive一致性良好(k>0.75),最佳结果为CEDM的CC视图和CEMRI的轴位MIP图。

临床应用与阅片要点

  • 作者认为轴位CEDM和MRI可作为影像复核及治疗计划的首选,CEDM的CC视图准确性最高。
  • 作者认为CEDM可作为CEMRI的替代模态。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the accuracy of contrast-enhanced digital mammography (CEDM) and MRI, including maximal intensity projection (MIP) images, for measuring the tumour size of breast cancer.

METHODS: We included 52 females (mean age, 50.9 years) with surgery due to breast cancer, and measured maximum diameter of main mass on mediolateral oblique (MLO) and craniocaudal (CC) views of mammography and CEDM; sagittal, axial MIP images, and early dynamic contrast-enhanced MRI (CEMRI) before surgery. Bland-Altman plot, intraclass correlation coefficient, and univariate linear regression analysis were used to evaluate the maximum size between imaging and pathology including only invasive component (OPinvasive) or with carcinoma in situ (OPmax).

RESULTS: Mean OPinvasive was 15.5 mm, and overestimation rate was similar or higher than underestimation rate on all images except CC view of mammography and axial MIP image of CEDM. Mean OPmax was 21.7 mm, and underestimation rate was higher than the overestimation rate. All parameters of CEDM and CEMRI showed good agreement ( k > 0.75) with OPinvasive, with the most favourable result being the CC view of CEDM and axial MIP image of CEMRI.

CONCLUSION: All views of CEDM and MRI provided accurate measurements of tumour size. Axial plane CEDM and MRI would be the first choice for image review and treatment planning, with the highest accuracy obtained by using CC view of CEDM.

ADVANCES IN KNOWLEDGE: Previous studies have not compared the measurement of the tumour size using detailed sequences; in our study, we discovered that CEDM can be an alternative modality to CEMRI.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Youn I, Choi S, Choi YJ, et al. Contrast enhanced digital mammography versus magnetic resonance imaging for accurate measurement of the size of breast cancer. Br J Radiol. 2019. PMID: 31017460. doi:10.1259/bjr.20180929

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。