文献速递乳腺乳腺X线

对比增强乳腺摄影在评估乳腺不对称中的附加价值

Added value of contrast-enhanced mammography in assessment of breast asymmetries.
PubMed 文献 · Br J Radiol · 2019-05-15

研究纳入125例乳腺X线摄影发现不对称的女性患者,评估对比增强光谱乳腺摄影(CESM)对不对称病灶的临床诊断效能。CESM敏感度为100%(超声-乳腺X线联合检查为97.8%),特异度为55.88%(联合检查为81.8%),阳性预测值和阴性预测值分别为85.85%和100%(联合检查分别为93.7%和93%)。作者认为局灶性和全局性不对称伴其他可疑乳腺X线表现与恶性显著相关,CESM在勾画肿瘤大小和范围方面起重要作用。

要点

  • CESM对乳腺不对称病灶的敏感度为100%,阴性预测值100%,有助于排除恶性。
  • CESM特异度55.88%低于超声-乳腺X线联合检查的81.8%,阳性预测值85.85%亦较低。
  • 无强化的不对称致密影若不作其他可疑影像表现,与良性病理相关。

核心结论

  • 局灶性和全局性不对称伴其他可疑乳腺X线表现与恶性显著相关,CESM在勾画肿瘤大小和范围方面起重要作用;无强化的不对称致密影若不作其他可疑影像表现,与良性病理相关。

研究设计与样本

  • 经放射科科研审查委员会批准并豁免知情同意的研究,纳入125例女性患者,其中33例(26.4%)为筛查、92例(73.6%)为诊断性乳腺X线摄影,所有患者乳腺X线摄影均发现不对称,均行超声检查和双能采集CESM。

关键影像表现/征象

  • 88/125(70.4%)为局灶性不对称(两个体位可见且占据小于一个象限)。
  • 26/125(20.8%)为全局性不对称(占据超过一个象限)。
  • 10/125(8%)为不对称(单个体位可见且占据小于一个象限)。
  • 1/125(0.8%)为新发不对称(既往乳腺X线摄影未见)。

诊断标准与关键数值

  • CESM敏感度100%,超声-乳腺X线联合检查敏感度97.8%。
  • CESM特异度55.88%,超声-乳腺X线联合检查特异度81.8%。
  • CESM阳性预测值85.85%、阴性预测值100%,超声-乳腺X线联合检查阳性预测值93.7%、阴性预测值93%。
  • 恶性病变91例、良性病变30例、高风险病变4例。

临床应用与阅片要点

  • 对乳腺X线摄影检出的不对称,CESM敏感度100%、阴性预测值100%,无强化且不作其他可疑影像表现的不对称致密影与良性病理相关。
  • CESM特异度55.88%、阳性预测值85.85%,低于超声-乳腺X线联合检查的81.8%和93.7%。
  • 作者认为CESM在勾画肿瘤大小和范围方面起重要作用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the clinical performance of contrast-enhanced spectral mammography (CESM) on asymmetries detected on a mammogram (MG).

METHODS: This study was approved by the Scientific Research Review Board of the Radiology Department, and waiver of informed consent was applied for the uses of data of the included cases. The study included 125 female patients,33 (26.4%) who presented for screening and 92 (73.6%) who presented for a diagnostic MG. All had breast asymmetries on MG. Ultrasound examination and CESM using dual-energy acquisitions were performed for all patients.

RESULTS: In all, 88/125 (70.4%) females had focal asymmetry (seen in two views and occupying less than a quadrant), 26/125 (20.8%) had global asymmetry (occupying more than one quadrant), 10/125 (8%) had asymmetry (seen in a single view and occupying less than a quadrant), and 1/125 had developing asymmetry (0.8%) (not present in the previous MG). Malignant lesions represented 91 cases, benign lesions represented 30 cases, and 4 cases were high-risk lesions. CESM sensitivity was 100% (v s 97.8 % for sono-mammography), specificity was 55.88% (v s 81.8% for sono-mammography), and the positive- and negative-predictive values were 85.85 and 100% (v s 93.7 and 93% for sono-mammography respectively) .

CONCLUSION: In our study, we conclude that focal and global asymmetries with other suspicious mammographic findings were statistically significant for malignancy and CESM played an important role in delineating tumor size and extension. Any non-enhancing asymmetrical density correlated with a benign pathology, if not associated with other suspicious imaging findings.

ADVANCES IN KNOWLEDGE:: Our study is the first to explore the added value of CESM to asymmetries detected in screening and diagnostic mammography.

来源:Br J Radiol,查看原文。版权归原作者所有。