文献速递乳腺MR

乳腺背景实质强化评估:不同乳腺MRI序列间评估者间与评估者内信度

Background parenchymal enhancement assessment: Inter- and intra-rater reliability across breast MRI sequences.
PubMed 文献 · Eur J Radiol · 2019-02-27

本研究纳入150例乳腺MRI,由3名放射科医生按BI-RADS四分法(极少量、少量、中等量、大量)定性评估背景实质强化(BPE),比较四种阅片策略的评估者间与评估者内信度。结果显示联合全部增强MRI图像的信度最高(Gwet‘s AC1=0.80),而MIP图像以较短阅读时间获得同等高信度(AC1=0.80)。

要点

  • 联合初始增强脂肪抑制T1加权、减影及MIP图像评估BPE的评估者间信度最高(AC1=0.80)。
  • 仅用MIP图像评估BPE的信度与联合全部增强图像相当(AC1均为0.80),且阅读时间更短。
  • 初始增强脂肪抑制T1加权图像单独评估BPE的信度最低(AC1=0.68)。

核心结论

  • 总体而言,联合全部增强MRI图像评估BPE的信度最高;但MIP图像以较短阅读时间显示出高信度。

研究设计与样本

  • 经机构审查委员会批准并豁免知情同意,3名放射科医生对150例乳腺MRI按BI-RADS四分法(极少量、少量、中等量、大量)定性评估BPE,比较四种模拟阅片策略的评估者间与评估者内信度,其中45例在初次评估四周后重复评估;采用有序加权的Gwet‘s AC1指数评估信度。

临床应用与阅片要点

  • 作者结论认为联合全部增强MRI图像评估BPE的信度最高,而MIP图像以较低阅读时间显示出高信度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate inter- and intra-rater reliability of background parenchymal enhancement (BPE) assessment across breast MRI sequences.

MATERIALS AND METHODS: Institutional review board approval was obtained and the requirement for consent was waived. Three radiologists qualitatively categorized BPE on 150 breast MRI using a four-point scale (minimal, mild, moderate or marked) according to BI-RADS category system. According to MR-sequence used for the assessment of BPE, inter-rater and intra-rater reliability across a simulated reading strategy with four options was performed: (1) initial contrast-enhanced (CE) fat-suppressed T1-weighted images (2) initial CE subtracted images (3) maximum-intensity-projection (MIP) of the first CE subtracted images (4) combination of initial CE fat-suppressed T1-weighted, initial CE subtracted and MIP images. Raters repeated BPE assessment of 45 breast MRI four weeks after the initial assessment. Gwet's AC1 index with ordinal weights was used to assess reliabilities.

RESULTS: Gwet's index for the reliability among the three raters was 0.68 (0.63-0.74) using initial contrast-enhanced fat-suppressed T1 weighted images, 0.74 (0.69-0.80) using subtracted images, 0.80 (0.76-0.83) using MIP, 0.80 (0.77-0.84) using a combination of the initial contrast-enhanced fat-suppressed T1 weighted, initial contrast-enhanced subtracted and MIP images. Test-retest reliability was 0.81 (0.60-1.00) for rater 1, 0.77 (0.55-0.98) for rater 2, 0.79 (0.59-0.99) for rater 3 using the combination of initial contrast-enhanced fat-suppressed T1 weighted, initial contrast-enhanced subtracted and MIP images.

CONCLUSIONS: Overall, the combination of all CE MRI images showed the highest reliability of BPE assessment. However, MIP showed a high reliability with lower reading time compared to the combination of all CE MRI images.

来源:Eur J Radiol,查看原文。版权归原作者所有。